Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD19-02660
StatusFinaled
Name BURNS WALL AND CEILING LLC
Site Address 8239 W FRANKLIN RD
Project NameMiracle Ear Boise Store
Customer Number 
ePlanReviewYes
Description
(MIRACLE EAR) **This is a partially sprinklered building. The Cafe Rio space is sprinklered for occupant load more than 100 - see BLD10-01207. The 2-hr fire resistance rated fire barrier wall located between Cafe Rio and Miracle Ear creates two fire areas and is required to be maintained.** Permit for remodel to existing 1,100 sq ft office space for new office tenant. Work to include: new interior non-bearing partition walls; new doors new ceiling grid panels with insulation above; interior finishes in compliance with Ch. 8 of the 2015 IBC. This building is partially fire sprinklered for A2 occupant load over 100. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR*
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 1/4/20202/6/2020 DONE
mailed 2-7-20
Third Notice 11/30/201912/30/2019 DONE
Second Notice 11/4/201911/25/2019 DONE
mailed 12-2-19
First Notice 10/18/201910/25/2019 DONE
mailed 11-1-19
Permanent Occupancy  10/8/2019 DONE
BLD-Final9/30/20199/30/20199/30/2019PPASS
DetailsMike Jordan
Tony Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection9/30/20199/30/20199/30/2019PPASS
DetailsTroy Cobbley
Life safety passed. Tony Phone #: ###-####
BLD-Ceiling Grid Inspection9/27/20199/30/20199/30/2019APASS
DetailsMike Jordan
Brett Phone #: ###-####
BLD-Ceiling Grid Inspection9/27/20199/27/20199/27/2019PPASS
DetailsTell Riley
firecaulk complete//grid ok//
BLD-Ceiling Grid Inspection9/27/20199/27/20199/27/2019PNR
DetailsTell Riley
Tony Phone #: ###-####//need to firecaulk all penetrations through 2 hour wall//
BLD-Ceiling Grid Inspection9/25/20199/26/20199/26/2019ANR
DetailsMike Jordan
Tony Phone #: ###-####. A mech. permit is required for the new and altered duct work that has been installed.
BLD-Framing/Rough-in9/3/20199/3/20199/3/2019PPASS
DetailsMike Jordan
Tony Phone #: ###-####. Walls have been repaired. Inteior steel stud framed walls ok. No grid at this time.
BLD-Framing/Rough-in8/29/20198/30/20198/30/2019AFAIL
DetailsMike Jordan
Tony Phone #: ###-####. Brace testing room walss as required. Firecaulk all penetrations in perimeter fire walls. Correction notice posted.
Issue PAID IN FULL permit  8/26/2019 DONE
Print Occupancy Form  8/26/2019 DONE
Meeting  8/23/2019 DONE
talked to GC, let know taht we need the GC form before we could issue
Route to Impact Fee Review8/22/20198/25/20198/22/2019 PASS
DetailsShannon Cade
Review requested for Commercial Permit
Plan assigned to (JAR)8/2/20198/2/20198/22/2019 DONE
DetailsJulie Romig
08/14 - L2 Miracle Ear
Routing - PLAN CHECK8/2/2019 8/22/2019 PASS
DetailsJulie Romig
1st review completed  8/22/2019 DONE
DetailsJulie Romig
PLANS/APPL TAKEN TO FRONT DESK  8/22/2019 DONE
Permit Ready to Issue  8/22/2019 DONE
MET
Need GC form
Routing - FIRE8/2/20198/2/20198/14/2019 PASS
DetailsMark Scharfen
08/14-Miracle Ear 518 fire review complete. Minor TI-No report needed. Passed review, inspector to field veriy extinguisher and e-lighting.
Routing - Addressing8/2/2019 8/5/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS8/2/2019 8/5/2019 PASS
DetailsAngela Hardy
Intake Approval  8/1/2019 PASS
DetailsJulie Romig
Intake Approval  7/31/2019 FAIL
DetailsJulie Romig
Newly uploaded sheets A2 and A3 are the correct size and have the stamping area required. Please upload all remaining sheets at the same size. Also, please rotate all sheets, including A2 and A3, so they are right side up for readability (ie, sheet number in bottom right hand corner).
Intake Approval  7/30/2019 FAIL
DetailsJulie Romig
Each sheet is required to be a minimum of 24"x18" sheet size and to scale. Each sheet is required to have a 4"x2" blank space for the city permit stamp located in the lower right hand corner, 3" from the right sheet edge. Sheet A1 meets all requirements, but other Miracle Ear sheets do not. Please reupload sheets A1-A4, D1-D6, E1-E2, and G1-G2 at 24"x18" minimum sheet size with blank space for stamp.
Intake Approval  7/23/2019 FAIL
DetailsJulie Romig
Need (items also circled on checklist):
1. Form 304 Registered Design Professional form completed and signed by owner.
2. Sheet A1 Floor plan stamped/signed by architect (same as Registered Design Professional).
3. Key Plan showing location of tenant suite within building.
4. Door schedule and door hardware schedule for new and existing doors.
5. If space is adjacent to Smash Burger or Café Rio, identify location of existing fire resistance rated walls.
Intake Approval  7/19/2019 FAIL
DetailsJulie Romig
1. Completed 518 Submittal Checklist and additional information as required by checklist.
Application received  7/17/2019 DONE
Application submitted via PDS Online on Jul 17 2019 11:33AM