Permit Information
Permit NumberBLD19-02700
StatusFinaled
Name MENDIOLA CUSTOM HOMES INC
Site Address 5858 N WILLOW CLIFF WAY
Project Name5858 Willow Cliff Way
Customer Number 
ePlanReviewYes
Description
TEMP C OF O UNTIL EASEMENT IS VACATED. **PLAN MODIFICATION - Updated engineering calculations and redlines for shear wall - no changes to floor plan. JJN 11/22/19** Permit for the construction of a new 2682 sq. ft., one story single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 646 sq. ft. of covered patio/porch and a 1944 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1A zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/3/20206/4/20206/4/2020APASS
DetailsTell Riley
screened // Brandon Phone #: ###-####//see zoning for easment vacation///
DOC - Permit Finaled6/4/20206/4/20206/4/2020PPASS
DetailsTell Riley
easment vacated and email recieved from zoning allowing occupancy//
BLD-Conference5/27/20206/5/20206/4/2020ACANC
DetailsTell Riley
follow up on easement// Brandon ###-####//
BLD-Conference4/29/20205/27/20205/27/2020ADONE
DetailsTell Riley
follow up on easement//###-####//Brandon//approved by council, waiting on signed resolution and ok from zoning//will follow up//
BLD-Conference3/25/20204/29/20204/29/2020ADONE
DetailsTell Riley
status on easments//Brandon Phone #: ###-####//discussed with Brandon, no information yet on if easment has been vacated// will check back in 30 days or Brandon will contact me//
BLD-Blower Door Test Results3/25/20203/25/20203/25/2020PDONE
DetailsTell Riley
2.49 ACH 50
BLD-Final3/24/20203/25/20203/25/2020APART
DetailsTell Riley
Brandon Phone #: ###-####//ok for temp until easment is vacated//check back 30 days//
BLD-Conference3/23/20203/24/20203/24/2020ADONE
DetailsTell Riley
call ahead // Brandon Phone #: ###-####
BLD-Wall Bracing1/7/20201/7/20201/7/2020PPASS
DetailsTell Riley
interior shear in garage, nailing verified by photos sent from contractor at joint, specifically asked about blocking and he asured that blocks were in place at time of nailing// ok to cover//
BLD-Wall Bracing1/6/20201/6/20201/6/2020PFAIL
DetailsTell Riley
brandon Phone #: ###-####//area in garage that needed blocked at joints and nailed has been taped and mudded--cannot see nails to verify blocking//CN still posted//
BLD-Wall Bracing12/31/201912/31/201912/31/2019PPART
DetailsTell Riley
brandon Phone #: ###-####//inside of house ok--tall wall in garage needs to be blocked at break (edges) and nailed for shear per plans//CN issued for garage area//
BLD-Wall Bracing12/27/201912/30/201912/30/2019PFAIL
DetailsTell Riley
Brandon Phone #: ###-####//need to add nails for 4" pattern per plans//add blocks and nails at edges on garage//
BLD-Wall Bracing12/23/201912/24/201912/24/2019AFAIL
DetailsTell Riley
brandon Phone #: ###-####//interior GB shear does not meet plans//add nails and block edges//
BLD-Energy code compliance12/12/201912/13/201912/13/2019APASS
DetailsTell Riley
Matt Phone #: ###-####
BLD-Framing/Rough-in12/12/201912/13/201912/13/2019APASS
DetailsTell Riley
Matt Phone #: ###-####//corrections made//
BLD-Framing/Rough-in12/9/201912/11/201912/11/2019APART
DetailsTell Riley
Matt Phone #: ###-####//correction notice posted//ok to insulate//
BLD-Wall Bracing12/5/201912/6/201912/6/2019APASS
DetailsTell Riley
shear // Matt Phone #: ###-####//plan mod changes reflect onsite shear per enginnering//
OVERRIDE  12/4/2019  
Plan assigned to (J_N)11/18/201911/18/201912/4/2019 DONE
DetailsJenny Nelson
Plan mod -
Routing - PLANNING11/18/2019 12/4/2019 PASS
DetailsJeff Lowe
NO C OF O UNTIL EASEMENT IS VACATED. HAVE BEEN IN CONTACT WITH APPLICANT ABOUT PROCESS.
Permit Ready to Issue  12/4/2019 DONE
plan mod approved
CHANGE STATUS TO (ISS)  12/4/2019 DONE
Routing - PLAN CHECK11/18/2019 11/22/2019 PASS
DetailsJenny Nelson
No floor plan changes, updated engineering for shear wall
Plan Modification Accepted  11/18/2019 DONE
Jeff Adalte from Mendiola Custom Homes called to start a plan mod workflow for new engineering for wall bracing. Sheets A1.1 and A1.2
BLD-Wall Bracing11/8/201911/12/201911/12/2019AFAIL
DetailsTell Riley
shear // Matt Phone #: ###-####//need plan mod for changes in shear locations--provide updated engineering as all shear walls are engineered//add hold downs at garage PFH per plans//
Routing - MECHANICAL11/6/2019 11/6/2019 PASS
DetailsTroy James
New manual j report
BLD-Footing8/26/20198/27/20198/27/2019APASS
DetailsTell Riley
Ryan Phone #: ###-####
BLD-Footing8/23/20198/23/20198/23/2019PPART
DetailsTell Riley
Ryan Phone #: ###-####//WIP//
Issue PAID IN FULL permit  8/12/2019 DONE
Inspection Record Card- Bld  8/12/2019 DONE
OVERRIDE  8/1/2019  
Plan assigned to (RDP)7/19/20197/19/20198/1/2019 DONE
DetailsRob Patrick
08/01 sfd L1 ePlan
Routing - PLAN CHECK7/19/2019 8/1/2019 PASS
DetailsRob Patrick
1st review completed  8/1/2019 DONE
DetailsRob Patrick
PLANS/APPL TAKEN TO FRONT DESK  8/1/2019 DONE
DetailsRob Patrick
Permit Ready to Issue  8/1/2019 DONE
email permits to mendiolacustomhomes@gmail.com and/or jeff@precisionframinginc.com
Routing - MECHANICAL7/29/2019 7/29/2019 PASS
DetailsChad Schwendiman
Routing - MECHANICAL7/19/2019 7/23/2019 FAIL
DetailsChad Schwendiman
Submitted plans show R-49 blow in ceilings. Need to Verify floor insulation, According to the application there should be rescheck form but I couldn't find it.
Route to Impact Fee Review7/19/20197/22/20197/22/2019 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - PLANNING7/19/2019 7/22/2019 PASS
DetailsJeff Lowe
Routing - PUBLIC WORKS7/19/2019 7/22/2019 PASS
DetailsAngela Hardy
Application received  7/19/2019 DONE
Application submitted via PDS Online on Jul 19 2019 10:09AM
Plans ACCEPTED BY PLAN TECH  7/19/2019 DONE
Intake Approval  7/19/2019 PASS
Recd Pcfee & Taken To Pln CK  7/19/2019 DONE
Routing - Addressing7/19/2019 7/19/2019 PASS
DetailsDoug Chausow