Permit Information
Permit NumberBLD19-03197
StatusFinaled
Name PANORAMA CONSTRUCTION
Site Address 2230 S CURTIS RD
Project Name2230 Curtis Street
Customer Number 
ePlanReviewYes
Description
**PLAN MODIFICATION - Covered patio engineering provided ok to build JJN 10-04-19** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 1214 sq. ft., one story single family dwelling with 3 bedrooms, 2 bathrooms, approximately 98 sq. ft. of covered patio/porch and a 476 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/2/20203/3/20203/3/2020APASS
DetailsMike Jordan
Jeff Phone #: ###-####
DOC - Permit Finaled3/3/20203/3/20203/3/2020PPASS
DetailsMike Jordan
All issues were resolved.
BLD-Blower Door Test Results3/3/20203/3/20203/3/2020ADONE
DetailsMike Jordan
5.5
BLD-Final2/27/20202/28/20202/28/2020ANR
DetailsTell Riley
Jeff Phone #: ###-####//install attic access door//insulate crawl access door//seal penetrations through garage separation wall//provide blower door test//CN posted//
BLD-Energy code compliance12/5/201912/6/201912/6/2019APASS
DetailsTell Riley
Jeff Phone #: ###-####
BLD-Framing/Rough-in12/4/201912/4/201912/4/2019PPASS
DetailsTell Riley
Jeff Phone #: ###-####//corrections made//engineering provided for trusses installed backwards--gussetts nailing and added webs installed per engineering//ok to insulate//
BLD-Framing/Rough-in12/2/201912/3/201912/3/2019AFAIL
DetailsTell Riley
jeff Phone #: ###-####//CN posted//need to fix truss clip north wall//add stud to beam pocket per engineering//add strap to portal frame on interior side per detail//provide engineered truss letter or fix for truss bearing points not lining up on wall per truss plans//
BLD-Wall Bracing11/4/201911/4/201911/4/2019PPASS
DetailsDave Hannah
shear // Jeff Phone #: ###-####
BLD-Footing10/7/201910/7/201910/7/2019PPASS
DetailsTell Riley
James Phone #: ###-####//ok per plans//
CHANGE STATUS TO (ISS)  10/7/2019 DONE
plan mod
OVERRIDE  10/4/2019  
Plan assigned to (J_N)10/1/201910/1/201910/4/2019 DONE
DetailsJenny Nelson
10/07 plan mod
Routing - PLAN CHECK10/1/2019 10/4/2019 PASS
DetailsJenny Nelson
1 hour plan mod fee
Permit Ready to Issue  10/4/2019 DONE
Plan Modification Accepted  10/1/2019 DONE
struc. engineering for porches
OVERRIDE  9/20/2019  
Plan assigned to (J_N)8/29/20198/29/20199/20/2019 DONE
DetailsJenny Nelson
09/11 sfd L1 ePlan. 1st complete 9/10, covered patio engineering
Issue PAID IN FULL permit  9/20/2019 DONE
Inspection Record Card- Bld  9/20/2019 DONE
Routing - PLAN CHECK9/20/2019 9/20/2019 PASS
DetailsJenny Nelson
PLANS/APPL TAKEN TO FRONT DESK  9/20/2019 DONE
DetailsJenny Nelson
Permit Ready to Issue  9/20/2019 DONE
met
1st review completed  9/10/2019 DONE
DetailsJenny Nelson
Routing - PLAN CHECK8/29/2019 9/10/2019 FAIL
DetailsJenny Nelson
Routing - PLANNING8/29/2019 9/3/2019 PASS
DetailsEthan Mansfield
Route to Impact Fee Review8/29/20199/1/20198/30/2019 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - Addressing8/29/2019 8/30/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS8/29/2019 8/30/2019 PASS
DetailsMorgan Webb
WEST BOISE SEWER DISTRICT
Routing - MECHANICAL8/29/2019 8/30/2019 PASS
DetailsTroy James
Intake Approval  8/29/2019 FAIL
no corrections form Brittany's fail
Intake Approval  8/29/2019 FAIL
they fixed the manual J's but didn't upload the ele sheet
Intake Approval  8/29/2019 PASS
Intake Approval  8/26/2019 FAIL
Manual J must have either address or lot, block and subdivision on the front, please upload electrical plan sheet
Application received  8/20/2019 DONE
Application submitted via PDS Online on Aug 20 2019 12:35PM