BLD-Final | 4/8/2020 | 4/9/2020 | 4/9/2020 | A | PASS |
Tony Young
|
|
|
BJ - screened for COVID 19 symptoms Phone #: ###-####
|
DOC - Permit Finaled | 4/9/2020 | 4/9/2020 | 4/9/2020 | P | PASS |
Tony Young
|
|
|
|
BLD-Blower Door Test Results | 4/9/2020 | 4/9/2020 | 4/9/2020 | P | DONE |
Tony Young
|
|
|
BJ - screened for COVID 19 symptoms Phone #: ###-####// 4.41
|
BLD-Conference | 4/7/2020 | 4/8/2020 | 4/8/2020 | A | PART |
Tony Young
|
|
|
?s on final,, needs trades,, drainage,, address
|
BLD-Energy code compliance | 1/16/2020 | 1/17/2020 | 1/21/2020 | P | PART |
Tony Young
|
|
|
robert Phone #: ###-####,, ok to cover main area
|
BLD-Energy code compliance | 1/15/2020 | 1/16/2020 | 1/16/2020 | A | NR |
Tony Young
|
|
|
robert Phone #: ###-####,,
|
BLD-Energy code compliance | 1/14/2020 | 1/15/2020 | 1/15/2020 | A | NR |
Tony Young
|
|
|
robert Phone #: ###-####,,
|
BLD-Energy code compliance | 1/13/2020 | 1/14/2020 | 1/14/2020 | A | NR |
Tony Young
|
|
|
robert Phone #: ###-####,,
|
BLD-Energy code compliance | 1/13/2020 | 1/13/2020 | 1/13/2020 | P | NR |
Tony Young
|
|
|
robert Phone #: ###-####,, call 1st
|
BLD-Framing/Rough-in | 1/10/2020 | 1/13/2020 | 1/13/2020 | A | PASS |
Tony Young
|
|
|
robert Phone #: ###-####,, call 1st// ok to insulate
|
BLD-Framing/Rough-in | 1/10/2020 | 1/10/2020 | 1/10/2020 | P | PEND |
Tony Young
|
|
|
robert Phone #: ###-####,, call 1st
|
BLD-Conference | 1/8/2020 | 1/10/2020 | 1/10/2020 | A | PASS |
Tony Young
|
|
|
robert Phone #: ###-####,, call 1st,, frame conf
|
BLD-Framing/Rough-in | 1/8/2020 | 1/8/2020 | 1/8/2020 | P | NR |
Tony Young
|
|
|
robert Phone #: ###-####,, needs seal pack,, will call in for a conf to meet for the frame inspection
|
BLD-Wall Bracing | 12/19/2019 | 12/19/2019 | 12/19/2019 | P | PASS |
Tony Young
|
|
|
BJ Phone #: ###-####// exterior nailing ok
|
BLD-Framing/Rough-in | 12/18/2019 | 12/19/2019 | 12/19/2019 | A | NR |
Tony Young
|
|
|
BJ Phone #: ###-####
|
BLD-Foundation | 11/14/2019 | 11/15/2019 | 11/15/2019 | P | PART |
Tony Young
|
|
|
Curtis Phone #: ###-####,, foundation walls,, work in progress
|
BLD-Footing | 11/6/2019 | 11/7/2019 | 11/7/2019 | A | PART |
Tony Young
|
|
|
Curtis Phone #: ###-#### PLANS ARE NEAR THE CHIMINEY// clean out roots,, add rebar to the portal frame areas, encase ground rod into center of concrete
|
Issue PAID IN FULL permit | | | 10/29/2019 | | DONE |
|
|
|
|
OVERRIDE | | | 10/28/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 8/26/2019 | 8/26/2019 | 10/28/2019 | | DONE |
Rob Patrick
|
|
|
09/06 sfd L1 PAPER...BLDG review is complete and ready to issue. Delivered entire package to Sue for her failure review.
|
Inspection Record Card- Bld | | | 10/28/2019 | | DONE |
|
|
|
|
Telephone call | | | 10/28/2019 | | DONE |
|
|
|
Spoke with Robert to inform him the permit is ready, that his RP expired and what fees are.
|
Routing - PLAN CHECK | 10/28/2019 | | 10/28/2019 | | PASS |
Rob Patrick
|
|
|
|
Case Summary (BLD) | | | 10/28/2019 | | DONE |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/28/2019 | | DONE |
Rob Patrick
|
|
|
|
Routing - PLANNING | 10/28/2019 | | 10/28/2019 | | PASS |
Sue Cummings
|
|
|
site plan changed to show two parking spaces outside setbacks
|
Permit Ready to Issue | | | 10/28/2019 | | DONE |
|
|
|
met: enrolled for class 11-6-2019. See docs
NEED
RP
|
Plan resubmittals received | | | 10/25/2019 | | DONE |
|
|
|
plans taken to Rob's desk- additional plans
|
Plan resubmittals received | | | 10/23/2019 | | DONE |
|
|
|
Stamped three full new set of plans and taken them to the plan reviewer
|
Plan resubmittals received | | | 10/17/2019 | | DONE |
|
|
|
Three copies of A-1 Site Plan stamped and taken to plan reviewer.
|
Routing - PLANNING | 10/17/2019 | | 10/17/2019 | | FAIL |
Sue Cummings
|
|
|
Still doesn't have 2 parking spaces
|
Plan resubmittals received | | | 10/16/2019 | | DONE |
|
|
|
3pkgs large drawings of 11 pages and REs check taken to Rob
|
Plan Reviewer's activity | | | 10/16/2019 | | |
Rob Patrick
|
|
|
Delivered entire package to Sue. Bldg review is complete and ready to issue.
|
Routing - PLANNING | 10/16/2019 | | 10/16/2019 | | FAIL |
Sue Cummings
|
|
|
Still requires two off street parking not located in setbacks.. No changeswere made. site plan needs labeled features
|
Plan Reviewer's activity | | | 10/16/2019 | | |
Rob Patrick
|
|
|
Emailed site plan labeling example to BJ.
|
Plan Reviewer's activity | | | 10/15/2019 | | |
|
|
|
Spoke with BJ and he will deliver new foundation plans because existing foundation is coming out of ground.
|
Plan Reviewer's activity | | | 9/13/2019 | | |
|
|
|
Delivered package to Doug in addressing for his review.
|
1st review completed | | | 9/13/2019 | | FAIL |
Rob Patrick
|
|
|
Multiple Corrections plus Engineering req'd, emailed Robert.
|
Routing - PLAN CHECK | 8/28/2019 | | 9/13/2019 | | FAIL |
Rob Patrick
|
|
|
Multiple Corrections plus Engineering req'd
|
Routing - Addressing | 8/26/2019 | | 9/13/2019 | | PASS |
Doug Chausow
|
|
|
|
Routing - MECHANICAL | 8/28/2019 | | 8/28/2019 | | PASS |
Chad Schwendiman
|
|
|
|
Route to Impact Fee Review | 8/26/2019 | 8/29/2019 | 8/27/2019 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - PLANNING | 8/27/2019 | | 8/27/2019 | | FAIL |
Sue Cummings
|
|
|
Requires 2 parking spaces outside of setbacks.
|
Routing - PUBLIC WORKS | 8/26/2019 | | 8/27/2019 | | PASS |
Morgan Webb
|
|
|
CREDIT FOR DEMO
|
Plans ACCEPTED BY PLAN TECH | | | 8/26/2019 | | DONE |
|
|
|
|
Intake Approval | | | 8/26/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 8/26/2019 | | DONE |
|
|
|
|
Application received | | 8/26/2019 | | | |
|
|
|
|