BLD-Final | 8/5/2020 | 8/7/2020 | 8/7/2020 | A | PASS |
Mike Jordan
|
|
|
Ok with video/photo // Tyler Phone #: ###-####
|
DOC - Permit Finaled | 8/7/2020 | 8/7/2020 | 8/7/2020 | P | PASS |
Mike Jordan
|
|
|
All issues were resolved..
|
BLD-Final | 8/4/2020 | 8/5/2020 | 8/5/2020 | A | PEND |
Mike Jordan
|
|
|
Tyler- */Screened*/ Phone #: ###-####. Needs to provide ignition barrier or DC coating to achoeve ignition barrier per the ESR report.
|
BLD-Energy code compliance | 5/14/2020 | 5/14/2020 | 5/14/2020 | P | PASS |
Mike Jordan
|
|
|
Screened- Tyler Phone #: ###-####
|
BLD-Framing/Rough-in | 5/12/2020 | 5/12/2020 | 5/12/2020 | P | PASS |
Mike Jordan
|
|
|
screened // Tyler Phone #: ###-####
|
BLD-Framing/Rough-in | 4/21/2020 | 4/22/2020 | 4/22/2020 | A | PASS |
Mike Jordan
|
|
|
screened // Tyler Phone #: ###-####. Framing issues in garage resolved. Ok to rock garage only.
|
BLD-Framing/Rough-in | 4/20/2020 | 4/21/2020 | 4/21/2020 | A | FAIL |
Mike Jordan
|
|
|
Screened-Tyler Phone #: ###-####. Nail off all simpson hangars. Nail off 3ply girder in garage per the engineering, plys not in contact. Complete lateral bracing on A01 thru A08 trusses. Fireblock common wall in garage with master at ceiling level. Correction notice posted. This framing inspection is for garage only.
|
BLD-Framing/Rough-in | 3/4/2020 | 3/4/2020 | 3/4/2020 | P | CANC |
Mike Jordan
|
|
|
anthony Phone #: ###-####
|
BLD-Wall Bracing | 3/4/2020 | 3/4/2020 | 3/4/2020 | P | PASS |
Mike Jordan
|
|
|
anthony Phone #: ###-####
|
Meeting | | | 2/18/2020 | | DONE |
|
|
|
Addressing changed address from 10622 W. Cruser Dr. to 10606 W. Cruser Dr. See Addressing form in documents.
|
BLD-Foundation | 10/29/2019 | 10/30/2019 | 10/30/2019 | A | PART |
Mike Jordan
|
|
|
Call prior to going Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD-Footing | 10/28/2019 | 10/29/2019 | 10/29/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD-Footing | 10/27/2019 | 10/28/2019 | 10/28/2019 | A | CANC |
Mike Jordan
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru Inspection cancelled via mobile web on Monday, October 28, 2019.
|
OVERRIDE | | | 10/24/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 9/16/2019 | 9/16/2019 | 10/24/2019 | | DONE |
Rob Patrick
|
|
|
09/27 sfd L1 PAPER...10/14 Failed; Need Tall Wall engineering
|
Plan Reviewer's activity | | | 10/24/2019 | | |
Rob Patrick
|
|
|
Emailed Tyler to follow-up on Manual J.
|
Plan resubmittals received | | | 10/24/2019 | | DONE |
|
|
|
two copies of manual j's. taken to Rob
|
Routing - MECHANICAL | 10/24/2019 | | 10/24/2019 | | PASS |
Troy James
|
|
|
|
Routing - PLAN CHECK | 10/24/2019 | | 10/24/2019 | | PASS |
Rob Patrick
|
|
|
|
Case Summary (BLD) | | | 10/24/2019 | | DONE |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/24/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 10/24/2019 | | DONE |
|
|
|
met
|
Inspection Record Card- Bld | | | 10/24/2019 | | DONE |
|
|
|
|
Telephone call | | | 10/24/2019 | | DONE |
|
|
|
Spoke with Tyler to inform him the permit is ready and what fees are due.
|
Issue PAID IN FULL permit | | | 10/24/2019 | | DONE |
|
|
|
|
Plan resubmittals received | | | 10/23/2019 | | DONE |
|
|
|
2 small sets of engineering plans,taken to Rob's desk
|
Plan Reviewer's activity | | | 10/14/2019 | | |
|
|
|
Gave Manual J to Troy for a re-submittal due to conditioned crawl and Man. J called out for R-30 when the walls have R-19.
|
1st review completed | | | 10/14/2019 | | FAIL |
Rob Patrick
|
|
|
Need Tall Wall Engineering.
|
Routing - PLAN CHECK | 9/16/2019 | | 10/14/2019 | | FAIL |
Rob Patrick
|
|
|
Need Tall Wall Engineering
|
Routing - FIRE | 9/20/2019 | 9/19/2019 | 9/30/2019 | | PASS |
Mark Stumbaugh
|
|
|
09/27 402 SFD Pond Home, paper No Fire Sprinklers Required
|
Routing - MECHANICAL | 9/18/2019 | | 9/20/2019 | | FAIL |
Troy James
|
|
|
Need to show floor as tight crawl with r-19 wall insulation.
|
Routing - PLANNING | 9/16/2019 | | 9/18/2019 | | PASS |
Jeff Lowe
|
|
|
|
Routing - PUBLIC WORKS | 9/16/2019 | | 9/18/2019 | | PASS |
Morgan Webb
|
|
|
|
Route to Impact Fee Review | 9/16/2019 | 9/19/2019 | 9/17/2019 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - Addressing | 9/16/2019 | | 9/17/2019 | | PASS |
Doug Chausow
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 9/16/2019 | | DONE |
|
|
|
|
Intake Approval | | | 9/16/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 9/16/2019 | | DONE |
|
|
|
|
BLD-Footing | 10/28/2019 | 10/28/2019 | | P | |
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|
Application received | | 9/16/2019 | | | |
|
|
|
|