Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD19-03759
StatusIssued
Name BARTON ANDREW M
Site Address 2726 N 29TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit to remodel existing home and add 810 sq ft of new Living Space. Alterations to existing to include: replacing Kitchen cabinets, fixtures and plumbing, relocating frunace and WH, relocating washer and dryer (Applicant will provide engineering for the beam replacing the existing bearing wall prior to removing the bearing wall). Addition will include adding a Living Room, Laundry Room, Powder, Master Bedroom, Master Bath, Master Closet and a covered rear patio. Separate electrical, plumbing and Mechanical permits are required. Applicant will provide Manual J if relocated furnace does not meet requirements. Smoke detectors and carbon monoxide alarms to updated as needed/required. Prescriptivee Energy Code is proposed. All work to be done as per plans, provided engineering, notes and local codes. ***BJM***
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Telephone call  7/10/2020 DONE
Parcel owner taking over project from Fernando Santos (RCT-46041) see email in documents
(F) Reprint permit  7/10/2020 DONE
BLD-Aging Inspection5/21/20205/21/20205/22/2020 PEND
DetailsTony Young
BLD-Energy code compliance1/7/20201/8/20201/8/2020APASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by fernando santos
BLD-Framing/Rough-in12/31/201912/31/201912/31/2019PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by fernando santos// needs a mechanical permit and inspection.. ok to insulate the walls
BLD-Conference11/1/201911/1/201911/1/2019PPASS
DetailsTony Young
fernando; Phone #: ###-####,, will cut down north wall,, poured 6" off,, re-form back and re-pour
BLD-Footing10/21/201910/21/201910/21/2019PPART
DetailsTony Young
Fernando Phone #: ###-####,, work in progress,, ok
BLD-Conference10/9/201910/10/201910/10/2019APASS
DetailsTony Young
Fernando Phone #: ###-####,, footing ?s.. ok to pour over old gravel areas,, will need to relocate sewer line,, will have rebar
Issue PAID IN FULL permit  9/27/2019 DONE
OVERRIDE  9/24/2019  
Plan assigned to (BJM)9/23/20199/23/20199/24/2019 DONE
DetailsBrian McGowan
Routing - PLAN CHECK9/24/2019 9/24/2019 PASS
DetailsBrian McGowan
1st review completed  9/24/2019 DONE
DetailsBrian McGowan
Case Summary (BLD)  9/24/2019 DONE
DetailsBrian McGowan
Inspection Record Card- Bld  9/24/2019 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  9/24/2019 DONE
DetailsBrian McGowan
Permit Ready to Issue  9/24/2019 DONE
Need
RP
GC (one listed on application is not in our system and the state website shows expired)
Telephone call  9/24/2019 DONE
Spke with Fernanado to inform him the permit is ready. The RCT number listed is expired and is not in our system and that we need an RP.
Routing Walk-In (Zoning)9/23/20199/23/20199/23/2019PPASS
DetailsJeff Lowe
Application received 9/23/2019