Permit Information
Permit NumberBLD19-03936
StatusFinaled
Name SAWTOOTH CONSTRUCTION GROUP INC
Site Address 3050 N LAKEHARBOR LN Unit: 201
Project NameGreat West Engineering Ste 201
Customer Number 
ePlanReviewYes
Description
(GREAT WEST ENGINEERING – SUITE #201) Permit to combine an existing 2,219 sq. ft. office tenant space with the adjacent 866 sq. ft. office tenant space to create a new office tenant space that is 3,085 sq. ft. within the 2nd floor of the existing building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of interior nonbearing walls, removal of select door/door frames, removal of millwork, construction of interior non-bearing walls, select new door/door frames, electrical work, plumbing work and interior finishes in compliance with Ch. 8 of the 2015 IBC. This building is fully Fire Sprinklered for area increase. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 7/13/20208/11/2020 DONE
MAILED 8-14-2020 WITH SECOND LETTER
Second Follow up  8/11/2020 DONE
Third Notice 5/12/20207/8/2020 DONE
MAILED 7-9-2020 WITH FIRST FOLLOW UP
First Follow up  7/8/2020 DONE
Third Notice 4/8/20205/7/2020 DONE
mailed 5-8-2020
Third Notice 3/10/20204/3/2020 DONE
mailed 4-6-2020
Second Notice 2/17/20203/5/2020 DONE
mailed 3-6-20
First Notice 2/3/20202/7/2020 DONE
mailed 2-10-20
Telephone call  1/24/2020 DONE
Spoke with Tish G, Joe B and Jim P, ok to give permanent occupancy since the fire alarm permit is for the whole building.
Permanent Occupancy  1/24/2020 DONE
BLD-Final1/22/20201/23/20201/23/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Kirsten Dallmann
FIRE-Final Inspection1/22/20201/23/20201/23/2020APASS
DetailsJim Page
Previously noted item has been corrected, fire sprinkler inspection is complete, a full fire alarm replacement is issued for this building under FIR19-00522, will verify fire alarm coverage during the final inspection for mentioned FIR permit, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete.

Final fire after sprinklers have been removed. Phone #: ###-#### Inspection requested via web by Kirsten Dallmann
FIRE-Final Inspection1/14/20201/15/20201/15/2020AFAIL
DetailsJim Page
2 areas have fire sprinklers that are less than 6 feet apart, fire sprinkler modifications are required for area of work to be compliant with NFPA13. Any and all fire sprinkler modifications requires a seperate permit.

are will be onsite after 9am. Phone #: ###-#### Inspection requested via web by Kirsten Dallmann
BLD-Framing/Rough-in12/11/201912/12/201912/12/2019APART
DetailsTony Young
Combining of Suites 201 and 205. Phone #: ###-#### Inspection requested via web by Kirsten Dallmann// walls ok after bracing tops per plan
Print Occupancy Form  11/4/2019 DONE
Issue PAID IN FULL permit  11/4/2019 DONE
Plan assigned to (JG)10/16/201910/16/201910/24/2019 PASS
DetailsJavier Guzman
1st rev comp, 10/21 L1 Great West Engineering Ste 201 ePlan
Routing - PLAN CHECK10/24/2019 10/24/2019 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  10/24/2019 DONE
Permit Ready to Issue  10/24/2019 DONE
all met: kirsten@sawtoothdevelopment.com

Need GC
Need Rev Val
Route to Impact Fee Review10/22/201910/25/201910/23/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  10/22/2019 FAIL
DetailsJavier Guzman
Routing - PLAN CHECK10/16/2019 10/22/2019 FAIL
DetailsJavier Guzman
Routing - Addressing10/16/2019 10/16/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS10/16/2019 10/16/2019 PASS
DetailsMorgan Webb
CREDIT FOR DEMO NO NEW FEES
Intake Approval  10/15/2019 PASS
DetailsJavier Guzman
Intake Approval  10/9/2019 FAIL
DetailsBrian McGowan
Please address or provide the following in order for your prescreen to be approved:

1. Sheet A1 and A2- The entire proposed tenant space is not shown. Please provide the entire space on these sheets.
Intake Approval  10/3/2019 FAIL
DetailsBrian McGowan
Please address or provide the following in order for your prescreen to be approved:
1. Provide a more detailed Key Plan so exiting can be verified from the proposed tenant space.
2. Sheet A1- The entire proposed tenant space is not shown. Please provide the entire space.
3. Sheet A1- Rooms need to be labeled for proposed use with square footage.
4. A2- No notes were provided for the Reflective Ceiling callouts.
Application received  10/2/2019 DONE
Application submitted via PDS Online on Oct 2 2019 10:08AM
Third Notice 8/16/2020