Permit Information
Permit NumberBLD19-04017
StatusFinaled
Name PAUL E MCNAMARA
Site Address 3825 W OVERLAND RD
Project NameCapital City Auto major T.I.
Customer Number 
ePlanReviewYes
Description
(CAPITAL CITY AUTO) ***CODE ALTERNATE - OCCUPANCY REDUCTION REQUEST APPROVED - SEE DOCUMENTS - POSTING OF OCCUPANT LOAD REQUIRED*** Permit to remodel an existing 1,540 sqft. building addition built previously without a permit. Work to include: Demo of attached shed that is over a property line, infill 1 window and 1 door on west wall within 5'-0" of property line, west wall to be 2-hr rated with proprietary wall assembly and parapet, new exterior door and insulation and siding on north wall, repair south wall gypsum and finish, and electrical work. Interior finishes shall be in compliance with Ch. 8 of the 2015 IBC. This building is partially fire sprinkled. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 as regulated by the Boise fire department. **MDH**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy  5/4/2020 DONE
BLD-Final4/30/20205/1/20205/1/2020PPASS
DetailsJim Storey
Screened-Paul Phone #: ###-####
BLD-Final4/20/20204/22/20204/22/2020PNR
DetailsJim Storey
Paul Phone #: ###-#### need ele
FIRE-Final Inspection4/20/20204/22/20204/22/2020APASS
DetailsTroy Cobbley
Life safety passed.

Paul Phone #: ###-####
Plan Reviewer's activity  4/22/2020 DONE
DetailsMichael Hanson
Changed the public works inspection from a "Y" to "N" per the approval comment from Morgan Webb "no new plumbing".
FIRE-Final Inspection4/13/20204/14/20204/14/2020PFAIL
DetailsJim Page
Ansul systems that was protecting the de-commissioned paint booth will need to be removed, a demo FIR permit is required for removal of the fire system. Provide single action door hardware on main entry as discussed, door hardware in place would not operate when locked. Provide fire extinguishers with current inspection tags and place as discussed. Provide maximum occupancy placard as shown on city approved drawings. Provide code compliant addressing on the fire access side of the building as discussed.

*screened* Check Ansul system, please call ahead for access - Paul Phone #: ###-####
BLD-Framing/Rough-in3/25/20203/27/20203/27/2020PPASS
DetailsJim Storey
Paul Phone #: ###-#### fire wall complet
BLD-Framing/Rough-in3/23/20203/24/20203/24/2020PPASS
DetailsJim Storey
Paul Phone #: ###-#### interior gyp ok parapet ok .
BLD-Conference3/3/20203/3/20203/3/2020PDONE
DetailsJim Storey
BLD-Framing/Rough-in2/19/20202/21/20202/21/2020ANR
DetailsJim Storey
Paul Phone #: ###-####
Plan Reviewer's activity  1/27/2020 DONE
DetailsMichael Hanson
Contacted Christy Little at ACHD and verified no impact fees would be required due to the CZC, age, and continued use of the building.
Issue PAID IN FULL permit  1/27/2020 DONE
Print Occupancy Form  1/27/2020 DONE
PLANS/APPL TAKEN TO FRONT DESK  1/7/2020 DONE
DetailsMichael Hanson
Permit Ready to Issue  1/7/2020 DONE
Need
ACHD
GC Form
Revised Cert of Value
Routing - FIRE12/19/2019 1/6/2020 PASS
DetailsMark Stumbaugh
Resubmittal Capital City Auto
Routing - PLAN CHECK12/23/2019 12/23/2019 PASS
DetailsMichael Hanson
Plan assigned to (M_H)11/6/2019 12/23/2019 DONE
DetailsMichael Hanson
1st review completed - 11/28 #520 L3 ePlan - Capital city auto
Routing - Design Review12/20/2019 12/20/2019 PASS
DetailsKayCee Babb
Per CZC19-00271, as revised 11-26-19 and 12-20-19.
Plan Reviewer's activity  12/19/2019 DONE
DetailsMichael Hanson
Provided occupancy reduction request template on 12/12/2019
Routing - MECHANICAL12/12/2019 12/12/2019 PASS
DetailsTroy James
Letter provided by owner stating that the existing spray booth will not be used. Therefore no mechanical work is being performed under this permit.
Route to Impact Fee Review12/5/201912/8/201912/6/2019 PASS
DetailsTravis P Black
Review requested for Commercial Permit
Routing - MECHANICAL12/2/2019 12/5/2019 FAIL
DetailsTroy James
Emailed corrections to applicant
1st review completed  12/5/2019 DONE
DetailsMichael Hanson
Routing - FIRE11/6/201911/6/201912/2/2019 FAIL
DetailsMark Stumbaugh
11/28 Capital City Auto L3
Routing - PLAN CHECK11/6/2019 12/2/2019 FAIL
DetailsMichael Hanson
See changemarks in ePlan for corrections required.
Routing - PLANNING11/6/2019 11/14/2019 PASS
DetailsDavid Moser
see CZC19-00271
Routing PW Environmental11/12/2019 11/12/2019 PASS
DetailsRick Christenson
Routing - PUBLIC WORKS11/6/2019 11/12/2019 PASS
DetailsMorgan Webb
NO NEW PLUMBING
Routing - Addressing11/6/2019 11/7/2019 PASS
DetailsDoug Chausow
Routing - Design Review11/6/2019 11/7/2019 FAIL
DetailsKayCee Babb
Comply with all conditions of approval of CZC19-00271.
Plan Reviewer's activity  11/1/2019 DONE
DetailsJavier Guzman
Carl M was ok with this being a 520
Intake Approval  11/1/2019 PASS
Intake Approval  10/10/2019 FAIL
DetailsJavier Guzman
For prescreen review provide and upload the following:
• Without having any permits or past C of O for the building addition will require a 502 application as if it were a new building. Provide and upload a completed 502 checklist along with any items requested by the 502 checklist.
• Structural design of the building can be a stamped letter from an Idaho licensed engineer or provide full structural design calculations from an Idaho licensed engineer
Application received  10/8/2019 DONE
Application submitted via PDS Online on Oct 8 2019 4:15PM