Permit Information
Permit NumberBLD19-04186
StatusFinaled
Name NAMASTE MARKET INC
Site Address 7100 W FAIRVIEW AVE
Project NameNamaste Restaurant - Hood
Customer Number 
ePlanReviewNo
Description
(NAMASTE RESTAURANT) This building is not fire sprinkled. Permit to install a new exhaust hood and take occupancy of an existing 5,580 sqft restaurant. No changes to the restaurant floor plan or occupancy allowed. Approval is contingent on adhering to the approved plans, engineering, and local codes and ordinances. MDH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/15/20201/16/20201/16/2020APASS
DetailsTell Riley
Suman Phone #: ###-####//ok per plans//advised to add signage at bathrooms and signage for accessible parking//no changes were made to building that were not permitted//
FIRE-Final Inspection1/15/20201/16/20201/16/2020APASS
DetailsTroy Cobbley
Life safety passed.

Suman Phone #: ###-####
Permanent Occupancy  1/16/2020 DONE
BLD-Final1/14/20201/15/20201/15/2020PCANC
DetailsTell Riley
Suman Phone #: ###-####//needs fire life safety inspection completed//
FIRE-Final Inspection1/14/20201/15/20201/15/2020AFAIL
DetailsTroy Cobbley
Provide emergency lighting as discussed and repair the exit sign. Provide occupant load sign and provide sticker at the keyed main exit door.

Suman Phone #: ###-####
BLD-Conference1/9/20201/10/20201/10/2020ADONE
DetailsTell Riley
remodeling inconsistent with the approved plans // Michael Hanson Phone #: ###-####//no one onsite,, posted a CN for plan modification if changes are or will be made in use or construction difereing from the scope of work on permit//
Issue PAID IN FULL permit  11/5/2019 DONE
Routing PW Environmental10/25/2019 11/5/2019 PASS
DetailsRick Christenson
Grease abatement review on-site. Signed off for hood install no plumbing permit listed.
Route to Impact Fee Review11/1/201911/4/201911/4/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
PLANS/APPL TAKEN TO FRONT DESK  11/4/2019 DONE
DetailsMichael Hanson
Case Summary (BLD)  11/4/2019 DONE
DetailsMichael Hanson
Print Occupancy Form  11/4/2019 DONE
Permit Ready to Issue  11/4/2019 DONE
MET
Need
GC Form (if applicant as the tenant is acting as the GC we need a letter from the parcel owner allowing them to act as their own GC)
Revised Value
Print Occupancy Form  11/4/2019 DONE
Telephone call  11/4/2019 DONE
Called and spoke with Suman to let him know we need a GC form and the Revised Value to assess fees before we can issue the permit.
Plan assigned to (M_H)10/18/2019 11/4/2019 DONE
DetailsMichael Hanson
1st review completed - 10/31 #518 L2 Paper - Asian restaurant
Routing - FIRE10/31/201910/31/201911/1/2019 PASS
DetailsErika Akin
Commercial Cooking:
Type 1 hoods shall be protected with an approved automatic fire-extinguishing system, designed, installed and tested in accordance with IFC Section 904 and NFPA 17A.

NOTE : A separate Cooking Hood Fire Extinguishing System permit is required to install and test such systems. (IFC 610 and 904.2.1)

Where a building fire alarm system is installed, automatic fire-extinguishing systems shall be monitored by the building fire alarm system in accordance with NFPA 72 (IFC 904.3.5).

System interconnection. The actuation of the fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking equipment. The fuel and electrical supply reset shall be manual. Electrical equipment that shuts down upon extinguishing system activation shall include but not be limited to receptacles, outlets, lights, switches, wire, and junction boxes, etc. The status of the exhaust fan shall be as specified by any special listing requirements of the hood, fan, and/or extinguishing system. However, in no case shall switches or connections for a fan that is to continue to run upon extinguishing system activation be allowed under the hood. (IFC 904.11)

A manual actuation device shall be located at or near a means of egress from the cooking area a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual actuation device shall be installed not more than 48 inches nor less than 42 inches above the floor and shall clearly identify the hazard protected. The manual actuation shall require a maximum force of 40 pounds and a maximum movement of 14 inches to actuate the fire suppression system. (IFC 904.11.1)

A portable fire extinguisher shall be provided within 30-ft travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5)

NOTE: Final approval will be subject to satisfactory field inspection by the PDS Fire inspector.
Routing - PUBLIC WORKS10/18/2019 11/1/2019 PASS
DetailsMorgan Webb
CONTACT WEST BOISE SEWER DISTRICT FOR FEES. ###-####
1st review completed  11/1/2019 DONE
DetailsMichael Hanson
Routing - PLAN CHECK10/30/2019 10/31/2019 PASS
DetailsMichael Hanson
Routing - MECHANICAL10/29/2019 10/30/2019 PASS
DetailsTroy James
Routing - Addressing10/18/2019 10/24/2019 PASS
DetailsDoug Chausow
Plans ACCEPTED BY PLAN TECH  10/18/2019 DONE
Recd Pcfee & Taken To Pln CK  10/18/2019 DONE
Intake Approval  10/18/2019 PASS
Application received 10/18/2019