Permit NumberBLD19-04980
StatusIssued
Name JORDAN WILCOMB CONSTRUCTION
Site Address 12475 W FRANKLIN RD
Project NameFranklin Commerce Ctr - Bldg 2
Customer Number 
ePlanReviewYes
Description
(FRANKLIN COMMERCE CENTER – BUILDING #2 - SHELL) The fire sprinkler system is used for building area increase and for fire area. To construct a new one story, 35,754 sq. ft. shell building. This is a shell only permit. This permit is NOT intended to establish a Certificate of Occupancy for any tenant. Future occupancies could include B, M, S-1, and F-1. Future tenants are required to apply for their own permit to establish occupancy. Approval is contingent upon adhering to the approved plans on file, DRH19-00263, attached engineering and plan review report. Work to include: site work, construction of concrete foundation and concrete slab, concrete tilt-up exterior wall panels, steel open-web roof girders, steel open-web roof joists, steel roof decking, rigid insulation installed on top or the roof deck with a single ply membrane roof covering, a 1-hr fire riser room with a door directly to the outside, exterior shade awnings, electrical work, mechanical work and plumbing work. Note: Special inspection is required, see attached 310 form. The building fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **JG**
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Concrete6/3/20206/3/20206/3/2020PPART
DetailsMike Jordan
Gene *screened* Phone #: ###-####. 7 Panels ok pending special inspection.
BLD-Footing5/5/20205/5/20205/6/2020PPART
DetailsMike Jordan
Gene Phone #: ###-####
BLD-Foundation4/28/20204/29/20204/29/2020APART
DetailsMike Jordan
Gene Pour time at 12 Phone #: ###-####. East and west step footings and north footing line. Work in progress. ok to place concrete pending special inspection.
BLD-Footing4/24/20204/24/20204/24/2020PDEFR
DetailsMike Jordan
Sreened-Rebar-Jean Phone #: 208-###-####. Interior column pad footings, ok pending special inspection.
BLD-Footing4/14/20204/15/20204/15/2020APASS
DetailsMike Jordan
Jean ***cleared*** Phone #: ###-####. south exterior footing ok.
Issue PAID IN FULL permit  3/20/2020 DONE
Inspection Record Card- Bld  3/20/2020 DONE
OVERRIDE  3/19/2020  
Plan assigned to (JG)1/10/20201/10/20203/19/2020 PASS
DetailsJavier Guzman
03/24 3rd rev - 502 Franklin Warehouse Bldg #2
Routing - PLAN CHECK3/18/2020 3/19/2020 PASS
DetailsJavier Guzman
Routing - PLANNING3/18/2020 3/19/2020 PASS
DetailsEthan Mansfield
signed off in eplan by Planning Ethan Mansfield
PLANS/APPL TAKEN TO FRONT DESK  3/19/2020 DONE
Permit Ready to Issue  3/19/2020 DONE
ALL MET (jnorton@jwci.com and ryan@larsonarchitects.biz)
GC
REV VALUES
ACHD
Routing - PLAN CHECK3/5/2020 3/18/2020 FAIL
DetailsJavier Guzman
Routing PW Drainage3/5/2020 3/12/2020 PASS
DetailsBrian Murphy
Routing - PLANNING3/11/2020 3/11/2020 PASS
DetailsEthan Mansfield
ROS has been recorded and finalized
Route to Impact Fee Review2/20/20202/23/20202/21/2020 PASS
DetailsTravis P Black
Review requested for Commercial Permit
Routing - FIRE1/10/20201/10/20202/20/2020 PASS
DetailsGreg Ruxton
Comments attached to case.
Routing Off Site - STRUCTURAL1/10/2020 2/20/2020 PASS
DetailsJavier Guzman
Signed off in ePlan by KPFF
Routing - PLAN CHECK1/10/2020 2/20/2020 FAIL
DetailsJavier Guzman
1st review completed  2/20/2020 FAIL
DetailsJavier Guzman
Routing - PLANNING1/10/2020 1/22/2020 FAIL
DetailsEthan Mansfield
The Record of Survey- Property Line Adjustment must be finalized before signing off on building permit.
Routing PW Drainage1/10/2020 1/21/2020 FAIL
DetailsBrian Murphy
MTI REPORT SAYS INFILTRATION TESTING REQURIED APENDX J GRADES
Routing - MECHANICAL1/10/2020 1/17/2020 PASS
DetailsTroy James
Routing PW Sewer Design1/10/2020 1/16/2020 PASS
DetailsDeAnn Brown
Routing - PLUMBING1/10/2020 1/14/2020 PASS
DetailsDaryl Spivey
Shell only, Plumbing fixtures to come with future T/I.
Routing - Design Review1/10/2020 1/13/2020 PASS
DetailsJosh Wilson
Routing PW Solid Waste1/10/2020 1/13/2020 PASS
DetailsEvan Carpenter
Routing PW Environmental1/10/2020 1/13/2020 PASS
DetailsRick Christenson
Routing PW Street Lights1/10/2020 1/13/2020 PASS
DetailsTom Marshall
Routing - Addressing1/10/2020 1/10/2020 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS1/10/2020 1/10/2020 PASS
DetailsMorgan Webb
SHELL ONLY, PLUMBING FIXTURES TO COME WITH FUTURE TI.
Routing - Erosion and Sediment1/10/2020 1/10/2020 PASS
DetailsMichael Zawacki
Site prep required.
Intake Approval  1/10/2020 PASS
DetailsJavier Guzman
Intake Approval  1/7/2020 FAIL
DetailsJavier Guzman
For prescreen review provide and upload the following:
• Per checklist provide a signed and approved by PDS Subdivision Staff Verification of Legal Lot or Parcel form
• Per checklist Provide site specific fire flow at hydrants letter from Suez Water or other public water provider
• Per checklist Provide DR/Planning & Zoning letters of approval.
• Per checklist provide a Landscape Plan showing location of trees, shrubs, groundcovers
• Per checklist provide a Plant Schedule identifying type of vegetation, quantity and size
• Per checklist Provide Erosion & Sediment Control (ESC) Narrative - Narrative must be designed for the specific project and be prepared and signed by a plan designer certified by Boise City.
• Per checklist Provide ESC Plans designed for the specific project and be prepared and signed by a plan designer certified by Boise City. If the ESC plans are found within the ESC narrative copy the ESC plan only (not the whole narrative) and upload it into the drawing file.
• Per checklist provide Electrical plans stamped, signed and dated by an Idaho licensed engineer to view Exit Signs and Emergency Lighting, to view Lighting Plan and Fixture Schedule, to view power plans, to view electrical fixture and equipment schedule, to view panel load summery, to view one-line diagram, to view electrical details and notes.
• Per ePlan submittal standards the reserve the bottom right corner on the drawing plans for the City electronic stamps. Leave a blank 4” x 2” space located 3” off the right sheet edge to allow for the title block on plan sheet S0.1, S4.1, see ePlan standards at https://www.cityofboise.org/media/7025/electronic_submittal_standards.pdf
• Per checklist provide a Lighting Compliance (COMcheck signed & printed on the plans)
Intake Approval  12/31/2019 FAIL
DetailsJavier Guzman
For prescreen upload the following:
• Upload a completed Checklist 502
• The checklist is not complete unless all information is filled out, all appropriate boxes are checked, and all plan page numbers are listed.
• Incomplete submittals will not be accepted. Applicants with incomplete submittals must upload additional documents
• 502 Checklist can be found at https://www.cityofboise.org/departments/planning-and-development-services/building/building-permits/commercial-construction-500/502-new-commercial-and-commercial-additions/
Application received  12/30/2019 DONE
Application submitted via PDS Online on Dec 30 2019 4:21PM
Routing - PLANNING3/5/2020   FAIL
DetailsEthan Mansfield
Waiting for Land Records Parcel Activity form from Surveyor. Cannot approve until this is submitted.