Permit Information
Permit NumberBLD20-00253
StatusIssued
Name NORTHERN CONSTRUCTION LLC
Site Address 825 N TROUTNER WAY
Project NameKissler Pool House
Customer NumberROUTE TO FIRE PLEASE
ePlanReviewYes
Description
HILLSIDE - WUI - MODIFICATION, INTERIOR WALL ADDED 4.16.20 **jab** Permit to build a 988sq' detached pool house. All work per plans, notations, engineering, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. **JAB** ***Sprinklers are not require***LGM A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Energy code compliance5/13/20205/14/20205/14/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Tammy Schacher
FIRE-Final Inspection5/13/20205/14/20205/14/2020ACANC
DetailsJim Page
Called point of contact listed on 13MAY2020 to inform that this project does not require a life fire safety signature as listed in permit details. No return call was received as of this entry, this request is cancelled.

Insulation Inspection on Pool House Phone #: ###-#### Inspection requested via web by Tammy Schacher
BLD-Framing/Rough-in5/11/20205/12/20205/12/2020APASS
DetailsBrandon Shaw
Garage Code # 2891
Pool House Framing Inspection Phone #: ###-#### Inspection requested via web by Tammy Schacher
Routing - MECHANICAL5/7/2020 5/7/2020 PASS
DetailsTroy James
ACCA report submitted for pool house
BLD-Wall Bracing5/1/20205/4/20205/4/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Tammy Schacher
CHANGE STATUS TO (ISS)  4/17/2020 DONE
OVERRIDE  4/16/2020  
Plan assigned to (JAB) Josh4/8/20204/8/20204/16/2020 PASS
DetailsJosh Bogle
plan mod
Routing - PLAN CHECK4/16/2020 4/16/2020 PASS
DetailsJosh Bogle
min. Mod fee
Permit Ready to Issue  4/16/2020 DONE
DO ISS- plan mod approved
BLD-Foundation4/8/20204/9/20204/9/2020APASS
DetailsBrandon Shaw
*screened* Jared Phone #: ###-####
BLD-Foundation4/7/20204/8/20204/8/2020ANR
DetailsBrandon Shaw
Need soil subgrade submitted and approved by PW...
BLD-Footing4/6/20204/7/20204/8/2020PPEND
DetailsDave Hannah
screened // Jared Phone #: ###-####
PubWorks Subgrade Approval4/8/20204/8/20204/8/2020 DONE
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Melissa Jannusch ###-####.

Intake Approval  4/8/2020 FAIL
Prescreen 1: Plan Mod
Please name new sheets the same name as previous documents. Files will have "v2" (version 2) next to file name.
Plan Modification Accepted  4/8/2020 DONE
Adding wall and double door.
BLD-Footing4/3/20204/6/20204/6/2020PCANC
DetailsDave Hannah
clear // Jared Phone #: ###-####
Issue PAID IN FULL permit  4/2/2020 DONE
Inspection Record Card- Bld  4/2/2020 DONE
OVERRIDE  3/31/2020  
Telephone call  3/31/2020 DONE
email sent ot- gary@northernconstructionhomes.com and jimk@norco-inc.com to informed them that not all fees were paid
Permit Ready to Issue  3/31/2020 DONE
Plan assigned to (JAB) Josh3/18/20203/18/20203/30/2020 PASS
DetailsJosh Bogle
03/24 pool house, ePlan
Routing - PLAN CHECK3/18/2020 3/30/2020 PASS
DetailsJosh Bogle
Plan Reviewer's activity  3/30/2020 DONE
DetailsJosh Bogle
recieved clarification from Kevin that structure is not an ADU - reviewed (PASS) - sent back to Fire for re-review
1st review completed  3/30/2020 DONE
DetailsJosh Bogle
PLANS/APPL TAKEN TO FRONT DESK  3/30/2020 DONE
DetailsJosh Bogle
ESC yes - Energy no
Plan Reviewer's activity  3/27/2020 DONE
DetailsJosh Bogle
unclear if this was being processed as an ADU or not - tagged Addressing, Mechanical, TCH
Routing PW Grading-Hillside3/18/2020 3/26/2020 PASS
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-#### with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at ###-####.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

Routing - FIRE3/18/20203/18/20203/19/2020 PASS
DetailsLee G Meredith
WUI pool house

Access distance exceeds the maximum allowed. Sprinklers are required. Applicant was informed to revise and resubmit.

3-23-20: After re-measuring and discussing with Romeo, it was determined that the fire access distance was within acceptable limits so sprinklers will not be required. Previously, drawings were failed in eplanreview. Applicant is aware that he will need to re-upload so fire activity can be passed.
Routing - Erosion and Sediment3/18/2020 3/18/2020 PASS
DetailsMichael Zawacki
Work and permit already exist for home.
Routing - MECHANICAL3/18/2020 3/18/2020 PASS
DetailsTroy James
Mechanical system and gas piping shall be verified by the mechanical inspector.
Routing - PLANNING3/18/2020 3/18/2020 PASS
DetailsKevin Holmes
Passed per approved CFH20-00007
Routing - Addressing3/18/2020 3/18/2020 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS3/18/2020 3/18/2020 PASS
DetailsRita DeYoung
No fees due for pool house
Plans ACCEPTED BY PLAN TECH  3/18/2020 DONE
Recd Pcfee & Taken To Pln CK  3/18/2020 DONE
Intake Approval  3/18/2020 PASS
Intake Approval  3/17/2020 FAIL
Please upload the geotechnical engineering report and related addendum prior to being accepted for building permit review. MMJ
Route to Impact Fee Review1/24/20201/27/20201/27/2020 PASS
DetailsTravis P Black
Initial residential review of new SFD permits requested for now.
Application received  1/24/2020 DONE
Application submitted via PDS Online on Jan 24 2020 2:05PM
Intake Approval  1/24/2020 FAIL
1. Please provide the Erosion Narrative to the documents folder.
2.Project will require a CAT II Hillside application prior to acceptance of the building permit application. Application #114 will need to be filled out and turned in to the Planning & Zoning counter at city hall with the application fee. Once the application has been approved by P&Z please upload the approval letter and then this building permit case can be routed for approval. Melissa Jannusch ###-####.
3. Please see personal email about filling out the 406 application and upload it into the documents folder (we will delete the 404 application once the correct application is filled out)