Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD20-00418
StatusIssued
Name SIMPLICTY HOMES LLC
Site Address 4110 W HILL RD
Project NameOUTUMURO RESIDENCE
Customer Number 
ePlanReviewYes
Description
WUI FOOTHILLS- ZONE "A" REQUIREMENTS. CLASS "A" ROOF REQUIRED. PRESCRIPTIVE ENERGY CODE PROPOSED. Permit for the construction of a new 1623 sq. ft., one story single family dwelling with 4 bedrooms, 2 bathrooms, approximately 58 sq. ft. of covered patio/porch and a 776 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. ***BJM*** ***Sprinklers are not required. all measurements are withing acceptable limits.***LGM A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Wall Bracing8/10/20208/11/20208/11/2020APART
DetailsTony Young
Kade - */Screened/* Phone #: ###-####// ok after nailing panels on plans rather than staples
BLD-Foundation7/6/20207/6/20207/6/2020PPASS
DetailsTony Young
screened // Sam Phone #: ###-####
BLD-Footing7/1/20207/1/20207/2/2020PPASS
DetailsTony Young
Sam *screened* Phone #: ###-####
BLD-Footing6/30/20207/1/20207/1/2020APART
DetailsTony Young
Phone #: ###-####// soils ok per e-mail from JT
BLD-Final6/26/20206/29/20206/29/2020ANR
DetailsTony Young
Sam Phone #: ###-####// wanted a footing inspection,, needs soils approval 1st
Issue PAID IN FULL permit  5/11/2020 DONE
Print Occupancy Form  5/11/2020 DONE
Telephone call  5/8/2020 DONE
sent email to jevans@simplicity-homes.com about ALL fees needing to be paid for issuance of permits
OVERRIDE  4/29/2020  
Plan assigned to (BJM)2/25/20202/25/20204/29/2020 DONE
DetailsBrian McGowan
04\28- 2nd Review Complete- SFD L2 ePlan
Routing - PUBLIC WORKS2/25/2020 4/29/2020 PASS
DetailsCandy A. Nichols
MORGAN PASSED IN E PLAN ON 2-25-20
Routing - PLAN CHECK4/29/2020 4/29/2020 PASS
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  4/29/2020 DONE
DetailsBrian McGowan
Permit Ready to Issue  4/29/2020 DONE
Met
Routing - PLAN CHECK4/23/2020 4/23/2020 FAIL
DetailsBrian McGowan
Routing PW Grading-Hillside4/20/2020 4/20/2020 PASS
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-#### with questions.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
1st review completed  3/27/2020 FAIL
DetailsBrian McGowan
Routing - PLAN CHECK2/25/2020 3/27/2020 FAIL
DetailsBrian McGowan
Routing PW Grading-Hillside2/25/2020 3/3/2020 FAIL
DetailsMelissa Jannusch
see changemarks in ePlan
Routing - PLANNING3/2/2020 3/2/2020 PASS
DetailsKarla Nelson
Ok per CFH19-00100
Route to Impact Fee Review2/25/20202/28/20202/26/2020 PASS
DetailsTravis P Black
Initial residential review of new SFD permits requested for now.
Routing - Addressing2/25/2020 2/26/2020 PASS
DetailsDoug Chausow
Routing - FIRE2/25/20202/25/20202/25/2020 PASS
DetailsLee G Meredith
Sprinkelrs are not required. All measurements are within acceptable limits. No written review comments provided.
Routing - PLANNING2/25/2020 2/25/2020 DONE
DetailsSue Cummings
set to karla again
Routing - Erosion and Sediment2/25/2020 2/25/2020 PASS
DetailsMichael Zawacki
Site prep required
Routing - MECHANICAL2/25/2020 2/25/2020 PASS
DetailsTroy James
Routing - PLANNING2/25/2020 2/25/2020 DONE
DetailsSue Cummings
Sent to Karla
Plans ACCEPTED BY PLAN TECH  2/25/2020 DONE
Recd Pcfee & Taken To Pln CK  2/25/2020 DONE
Intake Approval  2/25/2020 PASS
Intake Approval  2/18/2020 FAIL
NEED
ROTATE FLOOR LAYOUT PLAN
REScheck or PRESCRIPTIVE
Intake Approval  2/13/2020 FAIL
NEED
Grading & Drainage Plan
Truss Layout & Floor Layout Plan Sheet (too small)
Building Cross Section
REScheck
Foundation plan stamped & signed by engineer
ESC Narrative
Soils & Geo report
Application received  2/10/2020 DONE
Application submitted via PDS Online on Feb 10 2020 3:27PM
PubWorks Subgrade Approval7/1/20207/1/2020   

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
PubWorks Subgrade Approval6/30/20206/30/2020   
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.