Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD20-00810
StatusFinaled
Name STROTH GENERAL
Site Address 9213 W FAIRVIEW AVE
Project NameEnterprise Car Rental T.I.
Customer Number 
ePlanReviewYes
Description
(ENTERPRISE CAR RENTAL) This building is not fire sprinkled. Certificate of completion to be issued upon final inspection approval. Permit to remodel approximately 1,200 sqft of a 6,155 sqft existing office building tenant space. Work to include: demo non-bearing interior partitions, doors, millwork, plumbing and lighting fixtures, interior finishes. New work: non-bearing interior partitions, doors, millwork, plumbing and lighting fixtures, mechanical work, electrical work, plumbing work, and interior finishes. Interior finishes shall comply with ch. 8 of 2015 IBC. Approval is contingent on adhering to the approved plans, notations, local codes and ordinances. MDH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice7/23/20207/23/20208/11/2020 DONE
DetailsBrandon Shaw
MAILED 8-14-2020
BLD-Final7/23/20207/23/20207/23/2020PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Allen Nunnally
DOC - Permit Finaled7/23/20207/23/20207/23/2020PPASS
DetailsBrandon Shaw
FIRE-Final Inspection7/21/20207/22/20207/22/2020APASS
DetailsTroy Cobbley
Life safety passed.

Phone #: ###-#### Inspection requested via web by Allen Nunnally
FIRE-Final Inspection6/30/20207/1/20207/1/2020AFAIL
DetailsTroy Cobbley
Need current inspection for fire extinguisher, remove thumbturn dead bolt on west side door and provide sticker. Inspection performed by Greg

Phone #: ###-#### Inspection requested via web by Allen Nunnally
BLD-Final6/30/20206/30/20206/30/2020PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Allen Nunnally. Needs fire final. Called Allen and left message.
BLD-Ceiling Grid Inspection6/1/20206/2/20206/2/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Allen Nunnally
BLD-Framing/Rough-in4/23/20204/24/20204/24/2020APASS
DetailsMike Jordan
Inspection requested via web by rick pew. Interior steel stud framed walls and hardlid in bathroom. Noted to contractor that a mech. permit not yet pulled, flex for vent fan in bathroom needs inspected prior to cover.
Route to Impact Fee Review3/31/20204/3/20204/1/2020 PASS
DetailsShannon Cade
Review requested for Commercial Permit
Issue PAID IN FULL permit  4/1/2020 DONE
email permit and inspection card to- will@strothgeneral.com
Inspection Record Card- Bld  4/1/2020 DONE
Telephone call  4/1/2020 DONE
eplan will need to be release
Plan assigned to (M_H)3/19/2020 3/31/2020 DONE
DetailsMichael Hanson
03/24 #518 L1 ePlan - Enterprise Car Rental
Routing - PLAN CHECK3/19/2020 3/31/2020 PASS
DetailsMichael Hanson
1st review completed  3/31/2020 DONE
DetailsMichael Hanson
PLANS/APPL TAKEN TO FRONT DESK  3/31/2020 DONE
DetailsMichael Hanson
Permit Ready to Issue  3/31/2020 DONE
ALL MET

NEED
GC
REV VALUE
Routing - PUBLIC WORKS3/19/2020 3/20/2020 PASS
DetailsRita DeYoung
Credit for demo no new fees per Morgan
Routing - Addressing3/19/2020 3/19/2020 PASS
DetailsDoug Chausow
Intake Approval  3/18/2020 PASS
DetailsJavier Guzman
Intake Approval  3/10/2020 FAIL
DetailsBrian McGowan
Please address or provide the following for your Prescreen to be approved;
1. The Application needs to be uploaded.
2. Planning andf Zoning letters of approval for exterior modifications.
3. Door hardware to be specified on the plans per door. "All to match building standards" is not acceptable.
4. Sheet a2.31 is labeled a2.21 in the drawing folder. Just an (FYI)
5. The existing rooms and restrooms in the Public Lobby and Offices should be shown on a Key Plan. Egress from the entire building needs to be evaluated with the alterations. The plumbing fixture requirements for occupancy should be evaluated for compliance and noted on the plans.
6. It appears the new office area was storage or garage previously. A change of use requires the lighting and mechanical to be reevaluated for the new occupancy/use. Provide mechanical and electrical calculations and plans as required for a change of use in these areas OR letters (emails) from the Chief Electrical and Chief Mechanical Inspectors verifying no calculations and/or plans are required.
Application received  3/6/2020 DONE
Application submitted via PDS Online on Mar 6 2020 11:49AM
Second Notice 8/21/2020