Permit Information
Permit NumberBLD20-00965
StatusIssued
Name ETHOS DESIGN & REMODEL LLC
Site Address 1809 N 7TH ST
Project NameJensen Addition
Customer Number 
ePlanReviewYes
Description
Permit for a 440sq' addition that adds a bath & closet to create a Master Suite, adds a Dining room, adds a Mudroom, reconfigures the Kitchen, and relocates the Laundry. A 150sq' covered porch is part of the scope. Energy Code via alt-Prescriptive. All work per plans, attachments, engineering, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. **JAB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Energy code compliance7/14/20207/15/20207/15/2020APASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Kristen McNeill
BLD-Framing/Rough-in7/8/20207/8/20207/8/2020PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Kristen McNeill// ok to insulate// verify seal package
BLD-Framing/Rough-in7/2/20207/6/20207/6/2020ANR
DetailsTony Young
Pre-meeting to review current status (just waiting on HVAC and Plumbing rough in approvals) to see if there''s anything we''re missing.

Please call Kristen 30 minutes before - ###-#### Phone #: ###-#### Inspection requested via web by Kristen McNeill/// walk through// needs trades,, fire blocking, seal pack
Inspection Record Card- Bld  7/1/2020 DONE
BLD-Wall Bracing6/18/20206/19/20206/19/2020APASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Kristen McNeill
BLD-Wall Bracing6/18/20206/18/20206/18/2020PNR
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Kristen McNeill
BLD-Foundation6/1/20206/1/20206/1/2020PPART
DetailsTony Young
work in progress
BLD-Footing5/26/20205/27/20205/27/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Kristen McNeill
Issue PAID IN FULL permit  4/29/2020 DONE
Inspection Record Card- Bld  4/29/2020 DONE
Telephone call  4/28/2020 DONE
Contacted GC to let them know we still need an RP
OVERRIDE  4/23/2020  
Permit Ready to Issue  4/23/2020 DONE
ALL MET
Plan assigned to (JAB) Josh4/21/20204/21/20204/22/2020 PASS
DetailsJosh Bogle
Routing - MECHANICAL4/22/2020 4/22/2020 PASS
DetailsTroy James
Plan assigned to (JAB) Josh4/13/20204/13/20204/21/2020 PASS
DetailsJosh Bogle
04/17 addition, ePlan
Routing - PLAN CHECK4/13/2020 4/21/2020 PASS
DetailsJosh Bogle
1st review completed  4/21/2020 DONE
DetailsJosh Bogle
PLANS/APPL TAKEN TO FRONT DESK  4/21/2020 DONE
DetailsJosh Bogle
ESC yes - Energy yes
Routing - MECHANICAL4/15/2020 4/15/2020 FAIL
DetailsTroy James
Emailed corrections to designer.
Routing - PLANNING4/13/2020 4/13/2020 DONE
DetailsSue Cummings
sent to Ted V.
Intake Approval  4/13/2020 PASS
Plans ACCEPTED BY PLAN TECH  4/13/2020 DONE
Intake Approval  4/9/2020 FAIL
Prescreen 1
1. Please upload all drawings as individual files(not in one packet) and name according to what is on the page ex. DWG_Floor Plan 1, DWG_Electrical Plan
2. Two packets were uploaded that seem to have the same content but different dates. Please indicate if one should be deleted or if both relevant to scope of work.
3. Indicate code year 2015 IRC on cover page of plans
Application received  3/17/2020 DONE
Application submitted via PDS Online on Mar 17 2020 3:25PM