BLD-Wall cover | 6/29/2020 | 7/2/2020 | 7/2/2020 | P | PASS |
Tell Riley
|
|
|
corrections completed.insulation completed.contact Alex with any questions. ###-#### Phone #: ###-#### Inspection requested via web by Alex Macdonald//corrections completed//Energy ok//add 2 2x8 headers for opening at hallway--Alex will send photos//
|
BLD-Framing/Rough-in | 6/25/2020 | 6/26/2020 | 6/26/2020 | A | PART |
Tell Riley
|
|
|
Truss plans onsite. Call Alex at ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Alex Macdonald//CN posted for bearing wall corrections at center truss bearing//need to install FP and have inspected//ok to insulate--DO NOT INSULATE AREA WHER FP IS UNTIL IT HAS BEEN INSPECTED//
|
BLD-Framing/Rough-in | 6/17/2020 | 6/18/2020 | 6/18/2020 | A | FAIL |
Tell Riley
|
|
|
Call Alex with any questions. ###-####. Thanks! Phone #: ###-#### Inspection requested via web by Alex Macdonald//need truss plans//air seal needs completed//add stud next to cut stud at ele panel//desinger needs to specify headers over angled windows at front and rear of home//
|
CHANGE STATUS TO (ISS) | | | 6/4/2020 | | DONE |
|
|
|
|
OVERRIDE | | | 6/3/2020 | | |
|
|
|
|
Plan assigned to (D_S) Debbie | 6/2/2020 | 6/2/2020 | 6/3/2020 | | DONE |
Debbie Sanine
|
|
|
plan mod: add stand alone wood burning fireplace. Sheets A3 and A6
|
Routing - PLAN CHECK | 6/3/2020 | | 6/3/2020 | | PASS |
Debbie Sanine
|
|
|
|
Routing - MECHANICAL | 6/3/2020 | | 6/3/2020 | | PASS |
Troy James
|
|
|
plan mod adding fire place
|
Plan Reviewer's activity | | | 6/3/2020 | | DONE |
Debbie Sanine
|
|
|
No Building Review Plan Mod Fee to be charged
|
Permit Ready to Issue | | | 6/3/2020 | | DONE |
|
|
|
Plan Mod Met
|
Plan Modification Accepted | | | 6/2/2020 | | DONE |
|
|
|
plan mod requested by Alex Macdonald
|
BLD-Wall Bracing | 5/18/2020 | 5/19/2020 | 5/19/2020 | A | PASS |
Tell Riley
|
|
|
Please call Alex at ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Alex Macdonald//ok check hold downs at PFH on framing//
|
BLD-Wall Bracing | 5/15/2020 | 5/18/2020 | 5/18/2020 | A | NR |
Tell Riley
|
|
|
Call Alex at ###-#### with any questions! Phone #: ###-#### Inspection requested via web by Alex Macdonald
|
BLD-Foundation | 4/30/2020 | 5/1/2020 | 5/1/2020 | A | PART |
Tell Riley
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo //side 5' setback right on foundationn wall//front and rear ok// rebar ok per plans//discussed frost depth and drainage on 5' side, as elevation seems high//
|
BLD-Footing | 4/29/2020 | 4/30/2020 | 4/30/2020 | A | PART |
Tell Riley
|
|
|
south side, front and rear setbacks per plans//side with canal measured at center of bridge meets 15'4" on plans//rebar per plans//talked with Andy about ESC permit, notified concrete guys of washout containment, stated they would washout offsite//north side will need to comply with 2' frost depth requirements and contain water onsite--will need to be addressed by contractor//
|
BLD-Footing | 4/28/2020 | 4/29/2020 | 4/29/2020 | P | NH |
Tell Riley
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron aggregate construct//no one oniste//will reschedule//
|
Issue PAID IN FULL permit | | | 4/15/2020 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 4/15/2020 | | DONE |
|
|
|
|
OVERRIDE | | | 4/10/2020 | | |
|
|
|
|
Plan assigned to (D_S) Debbie | 4/8/2020 | 4/8/2020 | 4/10/2020 | | DONE |
Debbie Sanine
|
|
|
04/22/20 sfd L1 ePlan
|
Routing - PLAN CHECK | 4/8/2020 | | 4/10/2020 | | PASS |
Debbie Sanine
|
|
|
|
1st review completed | | | 4/10/2020 | | DONE |
Debbie Sanine
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/10/2020 | | DONE |
Debbie Sanine
|
|
|
|
Permit Ready to Issue | | | 4/10/2020 | | DONE |
|
|
|
met
|
Route to Impact Fee Review | 4/8/2020 | 4/11/2020 | 4/9/2020 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
|
Intake Approval | | | 4/8/2020 | | PASS |
|
|
|
|
Routing - MECHANICAL | 4/8/2020 | | 4/8/2020 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 4/8/2020 | | 4/8/2020 | | PASS |
Sue Cummings
|
|
|
No canal dimensions on the plat.
|
Routing - Addressing | 4/8/2020 | | 4/8/2020 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 4/8/2020 | | 4/8/2020 | | PASS |
Candy A. Nichols
|
|
|
CONTACT WEST BOISE DISTRICT
|
Intake Approval | | | 4/6/2020 | | FAIL |
|
|
|
Please provide the Manual J.
|
Application received | | | 4/3/2020 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 3 2020 5:06PM
|