Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberBLD20-01360
StatusIssued
Name CBH HOMES
Site Address 11114 W USTICK RD
Project Name13-1 Ustick Cottages
Customer Number01279EP & 01339-01341 & 01358-01361
ePlanReview 
Description
(8 GARAGES IN EPLAN UNDER BLD20-01279) Permit for a 264sq' garage attached to other garage(s) via a two-hour fire wall. Eaves permitted to cross property line per recorded plat. All work per plans, local codes and ordinances. Separate electrical permit required. **JAB**
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in8/4/20208/4/20208/4/2020PPASS
DetailsTell Riley
truss repair document reviewed//putty pad added to recepticles per the super, fire cualk was used at wall penetrations//ok to cover//
BLD-Framing/Rough-in7/29/20207/30/20207/30/2020AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Joel Hirtle***per Carl M. no rated exterior walls or soffits required due to common lots around all garages and the plat***

//provide truss engineering for trusses that appear to have been repaired in the field with gussets//low voltage ELE boxes for garage door sensors in the 2 hr wall, same stud bay will need to be protected per IRC 302.4.2//
//any through penetrations through the 2 hr walls need to be firestop protected in accordance with IRC R302.4.1.2//
BLD-Other7/30/20207/30/20207/30/2020PCANC
DetailsTell Riley
soffit Sheetrock inspections for both garages, please Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD-Wall Bracing7/5/20207/6/20207/6/2020PPASS
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD-Foundation6/7/20206/8/20206/8/2020APART
DetailsTell Riley
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo //measured setbacks from pins//need to adjust foundation to exact 2' setback on all sides//discussed with contact onsite and working on this when I left//hold downs and some forms still WIP//
BLD-Footing6/4/20206/5/20206/5/2020PPART
DetailsTell Riley
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo //WIP//pins set to measure 2' setback per the plat//met Ricardo and measured earlier today--crew will set strings at 2' setback for foundation inspection to confirm setbacks//
BLD-Footing6/1/20206/1/20206/1/2020PCANC
DetailsTell Riley
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo
Issue PAID IN FULL permit  5/28/2020 DONE
Inspection Record Card- Bld  5/28/2020 DONE
OVERRIDE  5/26/2020  
Permit Ready to Issue  5/26/2020 DONE
MET
Plan assigned to (JAB) Josh4/23/20204/23/20205/21/2020 PASS
DetailsJosh Bogle
04/29 garage, ePlan - 1st done
Routing - PLAN CHECK5/21/2020 5/21/2020 PASS
DetailsJosh Bogle
PLANS/APPL TAKEN TO FRONT DESK  5/21/2020 DONE
DetailsJosh Bogle
ESC yes - Energy no
1st review completed  5/8/2020 FAIL
DetailsJosh Bogle
Routing - PLAN CHECK4/23/2020 5/8/2020 FAIL
DetailsJosh Bogle
see notes in ePlan
Intake Approval  4/23/2020  
Intake Approval  4/23/2020  
Plans ACCEPTED BY PLAN TECH  4/23/2020 DONE
Intake Approval  4/23/2020 PASS
Application received 4/23/2020   
Application received 4/23/2020   
Routing - PLANNING4/23/2020