BLD-Framing/Rough-in | 8/11/2020 | 8/12/2020 | 8/12/2020 | P | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Scott Hawker. Needs to complete fireblocking and airseal.
|
Permit Ready to Issue | | | 7/30/2020 | | DONE |
|
|
|
**DO NOT REISSUE - PLAN MOD**
|
CHANGE STATUS TO (ISS) | | | 7/30/2020 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 7/1/2020 | 7/1/2020 | 7/29/2020 | | PASS |
Carl Westfall
|
|
|
plan mod - Dr. Scott Grant
|
Plan Reviewer's activity | | | 7/29/2020 | | PASS |
|
|
|
Plan mod review approved
|
Plan resubmittals requested | | | 7/28/2020 | | DONE |
|
|
|
|
Plan resubmittals received | | | 7/28/2020 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/28/2020 | | 7/28/2020 | | PASS |
Carl Westfall
|
|
|
1st plan mod - 3rd review approved
|
Routing - Design Review | 7/28/2020 | | 7/28/2020 | | PASS |
KayCee Babb
|
|
|
|
Routing Off Site - STRUCTURAL | 7/23/2020 | | 7/27/2020 | | PASS |
Carl Westfall
|
|
|
Jan Welch (Stapley)
|
Routing - Design Review | 7/23/2020 | | 7/27/2020 | | FAIL |
KayCee Babb
|
|
|
Comply with weather protection and access aisle changemarks.
|
Routing - PLAN CHECK | 7/22/2020 | | 7/23/2020 | | PASS |
Carl Westfall
|
|
|
Pending structural
|
Plan resubmittals received | | | 7/22/2020 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 7/15/2020 | | DONE |
|
|
|
|
Routing Off Site - STRUCTURAL | 7/6/2020 | | 7/15/2020 | | FAIL |
Carl Westfall
|
|
|
Jan Welch (Stapley)
|
Routing - Design Review | 7/6/2020 | | 7/10/2020 | | FAIL |
KayCee Babb
|
|
|
Comply with CZC20-00187 conditions of approval.
|
Routing - PLAN CHECK | 7/2/2020 | | 7/6/2020 | | PASS |
Carl Westfall
|
|
|
Plan intake review approved and drawings routed.
|
Routing - PLAN CHECK | 7/6/2020 | | 7/6/2020 | | PASS |
Carl Westfall
|
|
|
Pending structural
|
Routing - PLAN CHECK | 7/1/2020 | | 7/2/2020 | | FAIL |
Carl Westfall
|
|
|
Plan intake review of plan mod failed
|
Plan Modification Accepted | | | 7/1/2020 | | DONE |
|
|
|
additiona windows to W, S & E side. infield existing window openint to east side. removed wood fram canopies on E & N side, add new upper canopies on both sides with steel channel fram canopy above the main entry. added composiet exterios wall panel system below new canopies
|
Issue PAID IN FULL permit | | | 6/12/2020 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/12/2020 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 5/7/2020 | 5/27/2020 | 6/11/2020 | | PASS |
Carl Westfall
|
|
|
(1st done) 9 - 05/20/20 (L-3 - 15 days) (eplan - 34 sheets) Scott Grant DMD (back to applicant)
|
Plan resubmittals received | | | 6/11/2020 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 6/11/2020 | | 6/11/2020 | | PASS |
Carl Westfall
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/11/2020 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 6/11/2020 | | DONE |
|
|
|
MET Scott Hawker
GC
REVISED Cert of Value
|
Route to Impact Fee Review | 5/29/2020 | 6/1/2020 | 6/1/2020 | | PASS |
Shannon Cade
|
|
|
Review requested for Commercial Permit
|
Routing - PLAN CHECK | 5/7/2020 | | 5/29/2020 | | FAIL |
Carl Westfall
|
|
|
Revised drawings required
|
Plan resubmittals requested | | | 5/29/2020 | | DONE |
|
|
|
|
1st review completed | | | 5/29/2020 | | DONE |
|
|
|
|
Routing - FIRE | 5/7/2020 | 5/7/2020 | 5/26/2020 | | PASS |
Greg Ruxton
|
|
|
Attached comments to case.
|
Routing PW Environmental | 5/8/2020 | | 5/13/2020 | | PASS |
Zach Conde
|
|
|
AS PER ZACH: Passed on ePlan with this comment: “Approved with the documentation provided by Glenn Robinette showing required amalgam separator.” Please pass on Tidemark.
|
Routing - PUBLIC WORKS | 5/7/2020 | | 5/8/2020 | | PASS |
Morgan Webb
|
|
|
|
Routing - Erosion and Sediment | 5/7/2020 | | 5/8/2020 | | PASS |
Michael Zawacki
|
|
|
Interior TI, no ESC required
|
Routing - Design Review | 5/7/2020 | | 5/8/2020 | | PASS |
Michaella Owens
|
|
|
|
Routing - MECHANICAL | 5/7/2020 | | 5/7/2020 | | PASS |
Troy James
|
|
|
|
Routing - PLUMBING | 5/7/2020 | | 5/7/2020 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC and NFPA 99.
|
Routing - PLANNING | 5/7/2020 | | 5/7/2020 | | PASS |
Karla Nelson
|
|
|
Allowed use by Design Review is needed for any exterior changes.
|
Routing - Addressing | 5/7/2020 | | 5/7/2020 | | PASS |
Doug Chausow
|
|
|
|
Intake Approval | | | 4/30/2020 | | PASS |
|
|
|
|
Application received | | | 4/27/2020 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 27 2020 7:32AM
|
BLD-Framing/Rough-in | 8/13/2020 | 8/14/2020 | | P | |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by Scott Hawker
|