Permanent Occupancy | | 7/8/1996 | 7/8/1996 | | DONE |
|
|
|
|
INSP - Final | 7/8/1996 | | 7/8/1996 | | PASS |
|
|
|
corrections made ok. routed to Cathy for issuance of CO.
|
INSP - Permanent occupancy | | | 7/8/1996 | | PASS |
|
|
|
Perm. Occ. Cert. #6495 issued 7-8-96 to Mountain Billiards.
|
ISSUE OCCUPANCY FORM | | | 7/1/1996 | | |
|
|
|
|
ISSUE OCCUPANCY FORM | | | 7/1/1996 | | |
|
|
|
|
INSP - Propriety inspection | 9/25/1995 | 9/25/1995 | 9/25/1995 | | FAIL |
Bob Archibald
|
|
|
Cn issued
|
INSP - Carpentry | 8/7/1995 | 8/7/1995 | 8/7/1995 | A | PASS |
Bob Archibald
|
|
|
no call for inspection.
|
Inspection Record Card- Bld | | | 8/3/1995 | | |
|
|
|
|
Plan Reviewer's Copy of Permit | | | 8/3/1995 | | |
|
|
|
|
Telephone call | | | 8/3/1995 | | |
|
|
|
Applicant was called to brief him of procedures.
|
Permit taken to Permit Desk | | | 8/3/1995 | | |
|
|
|
|
(F) Issue permit | | | 8/3/1995 | | I |
|
|
|
|
Routing - BUILDING | 6/21/1995 | | 8/3/1995 | | |
|
|
|
The application was waiting for its turn to be reviewed. Per discussion with the applicant on July 28, 1995, the application is for an Occupancy Approval Review only. Regardless of what is shown on the (rejected) submitted drawings, no new work is proposed at this time.
|
Telephone call | 7/26/1995 | | 7/28/1995 | | |
|
|
|
Called the applicant and informed him that his application had been rejected. He told me that he wanted an Occupancy Approval Review only. We agreed that I could issue that type of permit without drawings.
|
Plan Reviewer's activity | | | 7/26/1995 | | |
|
|
|
Before the applicant can be contacted, Plan Check needs to review the Fire Department's file on this building. As of July 26, 1995 that file has not been reviewed. --UPDATE-- The Fire Department's file was reviewed July 28, 1995 by Carl J. Westfall. The correction of their concerns listed in past inspection reports should be verified by them.
|
Application DENIED | | | 7/26/1995 | | |
|
|
|
This building was built in 1970. Copies of the original 1970 drawings were obtained from the Building Department's micro fiche record. These copies were then revised and submitted for review by Plan Check. The revisions were not authorized by the original architect. This was verified by a phone call to D. Douglas Lindley (#416) on 07-25-95. He is the architect who's stamp appear on the submitted drawings. Since these drawings were not prepared, signed, and sealed by an architect licensed by the State of Idaho the Building Department rejected the application.
|
Application received | | | 6/21/1995 | | |
|
|
|
|