Permit Information
Permit NumberBLD96-00191
StatusFinaled
Name LOGGER CREEK PLAZA
Site Address 345 BOBWHITE CT
Project NameLOGGER CREEK PLAZA
Customer Number 
ePlanReviewNo
Description
To upgrade the core area first floor corridor to 1-hr. construction in accordance with approved plans on file. Work to include removal of existing suspended ceiling system in corridor and lobby and glazing sidelights on doors 2 and 14, relocate ducting as needed above new ceiling area, build a new 1-hr rated ceiling assembly, install smoke/fire dampers in ducting penatrations of new ceiling, fire-caulk all other penetrations of new ceiling, infill open areas where glazing removed in rated walls with new 1-hr rated assembly, provide new rated doors and rated sidelights in all required doors in corridor and provide for relocation of sprinkler heads and exit lighting and signage as per approved drawings. NOTE: Building is fully fire sprinklered. A separate Electrical, Mechanical, and Plumbing (Fire Sprinklers) Permit is required for this project. Plan Check # 041-96. PRP
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - C/O Approved  2/4/1999 PASS
l/c issued by 301 05-03-1996
INSP - Letter of compliance  6/14/1996 PASS
issued #11368 c of c by 301 this date.
INSP - Final6/13/19966/13/19966/13/1996PCANC
DetailsJim Sly
06/13/96 316 - Gave to J Storey.
INSP - Final6/13/19966/13/19966/13/1996 PASS
DetailsJim Storey
/ / 301 - FNL -OK FINAL
INSP - Framing/Rough-in5/2/19965/3/19965/3/1996APASS
DetailsJim Storey
05/02/96 301 - A.M. EARLY FRAM-OK FRAMING GWB -OK SHEETROCK NAILING TOP OF CORRIDOR LID.
INSP - Framing/Rough-in4/17/19964/17/19964/17/1996PPART
Details
PARTIAL. GRID A TO C. SUBJECT TO FIRE DAMPER APPROVAL.
Issue PAID IN FULL permit  4/8/1996
Permit taken to Permit Desk  2/20/1996 PASS
Issue
Plan Reviewer's activity  2/20/1996 PASS
fax to Arch correction that will become a part of this approved plans. "Red-Line" Plans. Issue
Routing - FIRE2/13/1996 2/20/1996 PASS
Inspection Record Card- Bld  2/20/1996
Plan Received by (PRP)2/12/1996 2/20/1996 PASS
Details
originally addressed to Marlene via letter dated 12/08/95 for prelimary answer to system proposed. 02/20/96 13:36:33 PRP - this action updated by action script from <<>> in Case No. BLD96-0191
Print Pending Permit.LaserJet4  2/13/1996 PASS
FILES
Waiting for Cert. of Value2/13/1996 2/13/1996
Plan Reviewer's activity  2/13/1996 PEND
REVIEW PLANS, INPUT TO PERMIT-PLAN, FORWARD TO FIRE, APPROVE FOR ISSUE.
Unassigned to Plan Reviewer2/2/1996 2/12/1996 PASS
02/12/96 14:42:53 PRP - this action updated by action script from <<>> in Case No. BLD96-0191
Plan routing begun/TENANTS  2/5/1996
This plan is to be reviewed by Plan Check and Fire Department only.
GAY'S RECEIPT FOR PARTIAL PAY  2/2/1996
Application received  2/2/1996
Routing - BUILDING2/20/1996   PEND