Permit Information
Permit NumberBLD96-00488
StatusFinaled
Name CROSSINGS INTERNATIONAL CORP
Site Address 767 E PARKCENTER BLVD
Project NameRIVERPLACE PHASE II
Customer Number 
ePlanReviewNo
Description
RIVER PLACE (PHASE II) SENIOR RESIDENTIAL CONGREGATE BUILDING-TO BUILD A NEW 57,530 SQ. FT., TWO STORY, SENIOR RESIDENTIAL CONGREGATE RESIDENCE. THIS BUILDING CONSISTS OF (58) SENIOR LIVING UNITS ON TWO FLOORS, WITH COMMERCIAL KITCHEN, COMMON DINING AND ACTIVITIES AREAS, ADMINISTRATIVE OFFICES, AS WELL AS, COMMON LAUNDRY, STORAGE, MECHANICAL AND HOUSEKEEPING AREAS. THIS BUILDING IS CONSTRUCTED OF WOOD FRAMED WALLS AND SECOND FLOOR, WOOD TRUSSED ROOF AND CONCRETE SLAB FIRST FLOOR. THIS PERMIT ALSO INCLUDES ALL RELATED SITE IMPROVEMENTS. THIS BUILDING WILL BE FULLY FIRE SPRINKLED. PC#111-96/DR#-32-95/CU#-148-89 AS MODIFIED/JCM
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection5/8/19975/8/19975/8/1997PPASS
Details
perm occupancy ok, storage plan approved per bld96-3198
Permanent occupancy  3/4/1997 PASS
Perm. Occ. Cert. #6800 issued 3-4-97 to Riverplace Estates.
Permanent occupancy  3/4/1997 PASS
Perm. Occ. Cert. #6800 issued 3-4-97 to Riverplace Estates.
Routing for occupancy3/3/19973/3/19973/3/1997 PASS
Art Yingling insp. for Final Occ.- Complies w/CU-148-89 & DR-32-95 - Signed Final.
INSP - Final3/3/19973/3/19973/3/1997PPASS
Details
EARLY PM, REINSPECT FOR FINAL, GRINNEL TO CORRECT FDC THIS AM fdc corrected, keys still not in knox box......manager to do tuesday
INSP - Final2/28/19973/3/19973/3/1997PPASS
DetailsJim Storey
03/03/97 301 - FINAL FOR C/O FNL -OK FINAL ì
Permanent Occupancy 3/3/19973/3/1997 DONE
Details
INSP - Final2/28/19972/28/19972/28/1997ANR
Details
late recheck fdc & tank not ready at 10:30 am still not ready at 4:00pm
INSP - Final2/27/19972/27/19972/27/1997PPART
Details
still need to rotate fdc and vent diesel tank
INSP - Occupancy Sign-off2/27/19972/27/19972/27/1997PCANC
DetailsJim Storey
02/27/97 301 - CANCLED BY CONTRACTOR.
INSP - Final2/20/19972/20/19972/21/1997PPART
Details
visual alarms in handicap rooms ok, reviewed emergency generator problems with contractor
INSP - Final2/18/19972/20/19972/20/1997APASS
DetailsJim Storey
02/20/97 301 - FNL -OK FINAL for temp occ. OTH-OTHER AGEN
Temporary occupancy  2/20/1997 PASS
Temp. Occ. Cert. #3371 issued 2-20-97 to Riverplace Phase II.
INSP - Temporary occupancy2/19/19972/19/19972/19/1997 PASS
DetailsJim Storey
/ / 301 - TCO -TEMP C OF O ISSUED
INSP - Final2/11/19972/11/19972/11/1997PPART
Details
TESTED GENERATOR, ISSUED C/N FOR PERMANENT OCCUPANCY, SIGNED TEMP OCC
INSP - Final2/7/19972/11/19972/11/1997APART
DetailsJim Storey
02/11/97 301 - FINAL FOR C/O. CORR-CORREC-CALL FOR REINSP WHEN COMPLETED OTH-OTHER AGENCIES NOT APPROVED
INSP - Final2/10/19972/10/19972/10/1997ANR
Details
reinspection...SPRINKLERS AND GENERATOR STILL NOT READY
INSP - Final2/10/19972/10/19972/10/1997PPART
Details
TO TEST COOKING HOOD, GENERATOR, AND SPRINKLERS HOOD OK, SPRINKLERS OK, GENERATOR NOT READY
INSP - Final2/5/19972/7/19972/7/1997AFAIL
Details
830 am alarms and sprinkler flow test SPRINKLERS STILL NOT WORKING, LONG C/N PUNCH LIST CREATED FOR GENERAL, SHOOTING FOR MONDAY
INSP - Final2/5/19972/5/19972/5/1997ANR
Details
alarm testing at 9 am alarms not ready, sprinklers not ready, rescheduled for fri am.
INSP-Supply line flush2/5/19972/5/19972/5/1997APASS
Details
need to verify piv does close piv functions after line flushed......lots of dirt and rocks
INSP-Sprinkler Rough-in/Hydro2/5/19972/4/19972/4/1997PPART
Details
ug hydro tested, not flushed, piv wont close
INSP-Sprinkler Rough-in/Hydro1/28/19971/30/19971/30/1997PPART
DetailsJoe Tawney
MIKE - ###-#### OK ON HYDRO TESTS FOR WET & DRY SYSTEMS
INSP - Energy code compliance1/15/19971/15/19971/15/1997PPASS
DetailsJim Storey
01/15/97 301 -
INSP - Wall cover1/15/19971/15/19971/15/1997 PASS
DetailsJim Storey
/ / 301 - shaft for kitchen hood ok
INSP - Energy code compliance12/17/199612/20/199612/23/1996APASS
DetailsJim Storey
12/23/96 301 - INSL-OK INSULATION-ENERGY CODE
INSP - Framing/Rough-in12/17/199612/19/199612/19/1996APASS
DetailsJim Storey
12/19/96 301 - FRAM-OK FRAMING a-3 occ area
INSP - Energy code compliance12/17/199612/17/199612/17/1996PPASS
DetailsJim Storey
12/17/96 301 - INSL-OK INSULATION-ENERGY CODE
INSP - Framing/Rough-in12/13/199612/17/199612/17/1996PPASS
DetailsJim Storey
12/17/96 301 - FRAM-OK FRAMING
INSP - Framing/Rough-in12/13/199612/13/199612/13/1996PNR
DetailsJim Storey
12/13/96 301 - OTH-OTHER AGENCIES NOT APPROVED ele. n/r for framing.
INSP - Framing/Rough-in12/11/199612/12/199612/12/1996PPASS
DetailsJim Storey
12/12/96 301 - PRE-INSULATION IN ATTIC GWB -OK SHEETROCK NAILING
INSP - Energy code compliance12/6/199612/9/199612/9/1996APASS
DetailsJim Storey
12/09/96 301 - EARY MONDAY A.M. INSL-OK INSULATION-ENERGY CODE
INSP - Framing/Rough-in12/6/199612/9/199612/9/1996APASS
DetailsJim Storey
12/09/96 301 - EARLY A.M. FRAM-OK FRAMING
INSP - Framing/Rough-in12/5/199612/5/199612/5/1996PFAIL
DetailsJim Storey
12/05/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Energy code compliance12/2/199612/3/199612/3/1996APASS
DetailsJim Storey
12/03/96 301 - EARLY A.M. INSL-OK INSULATION-ENERGY CODE
INSP - Framing/Rough-in11/26/199612/3/199612/3/1996PPASS
DetailsJim Storey
12/03/96 301 - FRAM-OK FRAMING
INSP - Framing/Rough-in11/26/199611/27/199611/27/1996PPART
DetailsJim Storey
11/27/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED ok to insulate.
INSP - Framing/Rough-in11/22/199611/26/199611/26/1996PCANC
DetailsJim Storey
11/25/96 301 - contractor cancled
INSP - Fire Dept. Request11/19/199611/19/199611/19/1996 PASS
Details
/ / 405 - middle wing, 2nd floor ok to cover...c/n isues resolved
INSP - Framing/Rough-in11/18/199611/19/199611/19/1996APART
DetailsJim Storey
11/19/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Conference11/19/199611/19/199611/19/1996 PASS
Details
/ / 405 - reviewed alarm plans with installer
INSP - Fire Dept. Request11/15/199611/15/199611/15/1996 FAIL
Details
/ / 405 - rough-in middle wing, 2nd floor, failed...c/n issued support spacing excessive where crossing copper water lines
INSP-Conference11/13/199611/13/199611/13/1996 PASS
Details
DISCUSSED ELEVATOR SHAFT SPRINKLER REQUIREMENTS, GAVE CONTRACTOR LETTER IN WRITING
INSP - Final11/8/199611/12/199611/12/1996ANR
DetailsJim Storey
11/12/96 301 -
INSP - Framing/Rough-in11/12/199611/12/199611/12/1996PPASS
DetailsJim Storey
11/12/96 301 - FRAM-OK FRAMING INSL-OK INSULATION-ENERGY CODE south wing first floor only.
INSP-Sprinkler Rough-in/Hydro11/7/199611/7/199611/7/1996 PART
Details
NORTH WING ATTIC AND 2ND FLOOR APPROVED FOR COVER
INSP - Framing/Rough-in11/1/199611/4/199611/4/1996PFAIL
DetailsJim Storey
11/04/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Framing/Rough-in11/4/199611/4/199611/4/1996 FAIL
DetailsJim Storey
10/31/96 301 - EARLY AS POSSIBLE PLEASE CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Wall cover10/17/199610/17/199610/17/1996PPASS
DetailsJim Storey
10/17/96 301 - EXTERIOR SHEER WALL NAILLING OK FRONT OF BLDG.
INSP - Conference8/29/19968/29/19968/29/1996 PASS
DetailsJim Storey
/ / 301 - pre-const meeting w/arch, owner,genral and subcontractors.
INSP - Conference8/29/19968/29/19968/29/1996 PASS
Details
/ / 405 - precon meeting
INSP - Conference8/26/19968/26/19968/26/1996 PART
Details
/ / 405 - chk FD access to site, radius, etc entrance only 15 ft wide from park center, numbering needs to be discuss to how to mark buildings. hydrants somewhat diffewrent than plans ...as builts should be prov
(F) Reprint permit  7/22/1996
INSP - Footings7/19/19967/22/19967/19/1996ACANC
DetailsJim Sly
07/19/96 316 - Cancel...sent to...
Issue PAID IN FULL permit  7/19/1996
ISSUE OCCUPANCY FORM  7/19/1996
Inspection Record Card- Bld  7/19/1996
Permit taken to Permit Desk  7/19/1996 PASS
Plan resubmittals received  7/16/1996 PASS
Plan resubmittals requested  7/11/1996 PEND
Plan resubmittals received  7/10/1996 PEND
Plan resubmittals requested  6/28/1996 PEND
Routing - MECHANICAL6/26/1996 6/27/1996 PASS
a
Routing - PUBLIC WORKS6/20/1996 6/26/1996 PASS
Plan Received by (JCM)5/20/1996 6/26/1996 PASS
DetailsJohn Menard
06/26/96 10:20:25 PRP - this action updated by action script from <<>> in Case No. BLD96-1110
Plan resubmittals received  6/24/1996 PEND
Routing Off Site - C.D.H6/7/1996 6/20/1996 PASS
CONTACTED BRUCE TAYLOY FOR CDH PICKUP AT ###-####
Routing - PUBLIC WORKS6/4/1996 6/7/1996 FAIL
REQUIRES STREET LIGHT PLAN
90 day tracking............. 3/6/19966/4/1996 PASS
Routing - FIRE5/29/1996 6/4/1996 PASS
Plan resubmittals requested  5/29/1996 PEND
CORRECTION LIST MAILED TO ARCHITECT 05/29/96 A.M.
Routing - PUBLIC WORKS5/15/1996 5/15/1996 PEND
Jon Williams of PW picked up plans. 5/15/96 DAR
Routing - ELECTRICAL5/8/1996 5/13/1996 PASS
Routing - MECHANICAL4/30/1996 5/7/1996 FAIL
Unassigned to Plan Reviewer3/6/1996 5/2/1996 PASS
05/02/96 16:56:40 PRP - this action updated by action script from <<>> in Case No. BLD96-0489
Routing Off Site - A.C.H.D4/5/1996 4/29/1996 FAIL
Notified Chris Dalengas to have plans picked up and taken to ACHD. Phone ###-####. DAR 4//5/96.
Routing - PLUMBING4/1/1996 4/4/1996 PASS
Routing - PLANNING3/25/1996 3/29/1996 PASS
X-ref: DR-32-95, CU-148-89. Approved by MS & RC.
Routing - PUBLIC WORKS3/8/1996 3/25/1996 FAIL
Plan routing begun/NEW & ADDTN  3/8/1996 PASS
GAY'S RECEIPT FOR PARTIAL PAY  3/6/1996
Application received  3/6/1996
Plans taken to Plan Check  3/6/1996 PASS
Received Certificate of Value  3/6/1996 PASS
Routing - BUILDING6/26/1996   PEND
Routing - BUILDING6/27/1996   PEND