Permit Information
Permit NumberBLD96-02884
StatusFinaled
Name SAFELITE AUTO GLASS
Site Address 6312 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
To remodel the interior of an existing 8,319 sq.ft. building for one tenant per approved plans on file. Work to include installation of a new 10 ft. wide overhead door on the east side of building, removal of a 3 ft. man door on the south side, construction of new Occupancy separation walls around the central core and between the service area and the warehouse, construction of new interior partition walls and installation of 1-hr fire shutters where shown along with interior finish as per approved plans. (P.C.#630-96) prp
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 3/27/19973/27/1997 DONE
Details
INSP - Final3/27/19973/27/19973/27/1997PPASS
Details
03/27/97 338 - made ok
Permanent occupancy  3/27/1997 PASS
Perm. Occ. Cert. #6817 issued 3-27-97 to Safelite Auto Glass.
Permanent occupancy  3/27/1997 PASS
Perm. Occ. Cert. #6817 issued 3-27-97 to Safelite Auto Glass.
INSP - Final3/25/19973/25/19973/25/1997PPASS
DetailsJoe Tawney
03/25/97 406 - FINAL REINSP OK FOR CERT OF COMPLETION STORAGE RACKS TO SEPARATE PERMIT
INSP - Final3/25/19973/25/19973/24/1997PPART
Details
03/25/97 338 - ok for temp only until the storage rack permit is issueed
INSP - Final3/24/19973/24/19973/24/1997PFAIL
DetailsJoe Tawney
03/24/97 406 - FINAL FAILED TAG EXT LETTERING OVER DOOR INSTALL EMERG WALL
INSP-Conference3/21/19973/21/19973/21/1997APASS
Details
reviewed storage plans for racks. comb storage will be under 12 ft, no high haz storage issues, need rack permit from structural
INSP - Final3/19/19973/20/19973/19/1997ANR
Details
03/20/97 338 - HE WILL CALL TO SCHEDULE OTH-OTHER AGENCIES NOT APPROVED
INSP - Foundation3/11/19973/11/19973/11/1997PPASS
Details
03/12/97 338 - RETAINING WALLS r-bar placed okto pour
INSP - Foundation2/27/19972/28/19972/28/1997PPASS
Details
02/28/97 338 - for the loading dock
INSP - Framing/ Rough-in2/21/19972/21/19972/21/1997 PASS
Details
/ / 338 -
INSP - Framing/Rough-in2/20/19972/20/19972/20/1997PCANC
Details
02/20/97 338 - RESCHEDULED 02/21/97
INSP - Conference2/13/19972/14/19972/14/1997APASS
Details
02/14/97 338 - made ok
INSP-Conference2/12/19972/12/19972/12/1997 PASS
CONF ON INST OF FIRE ASSYS REFERRED TO STRUCT DEPT ALSO DISCUSSED FUSIBLE LINKS AND EXIT DOORS
INSP - Miscellaneous2/10/19972/10/19972/10/1997 PASS
Details
/ / 338 - deliver approved resubmittals to jobsite
INSP - Miscellaneous2/10/1997 2/9/1997 PASS
REVIEWED RESUBMITTALS AND ATTACHED TO OFFICE COPY OF PLANS ALSO APPROVED SAME
Inspection Record Card- Bld  2/7/1997
Print Occupancy Form  2/7/1997
CHANGE STATUS TO (I)  2/4/1997
INSP - Conference2/3/19972/3/19972/3/1997 FAIL
Details
/ / 338 - conference to reject plans submitted as there is no seal on plans rejected
Plan assigned to (338)2/2/1997 2/2/1997 PEND
FIRE DOOR DETAILS REQUESTED AND MARKED ON THE PLANS TO BE SUPPLIED TO THE INSPECTOR AT THE TIME OF FIRST ROUGH IN INSPECTOR.
Plan resubmittals received  1/30/1997 PEND
RECIEVED PLANS FROM PLAN REVIEWER PRP AS PERMIT WAS ISSUED.
INSP - Conference1/30/19971/30/19971/29/1997PPASS
Details
01/30/97 338 - made ok
90 day tracking............. 10/24/19961/22/1997
Issue PAID IN FULL permit  1/21/1997
Plan assigned to (PRP)10/25/1996 12/6/1996 PASS
Details
12/06/96 14:18:26 PRP - this action updated by action script from <<>> in Case No. BLD96-2884
Telephone call  12/6/1996
JERY FRAZOER RETURNED MY CALL, GAVE HIM FEE'S DUE. SINCE THEY ARE OUT THEY WILL HAVE SEND SUPER UP TO GET PERMIT, MIGHT NOT BE UNTIL AFTER X-MAS
Telephone call  12/6/1996
LEFT MESSAGE ON JERRY FRAZOERS MACNINE
Inspection Record Card- Bld  12/6/1996
Print Occupancy Form  12/6/1996
PLANS/APPL TAKEN TO FRONT DESK  12/6/1996 PASS
issue
Plan resubmittals received  12/6/1996 PASS
received all that was requested, assembled and issued.
Routing - PLAN CHECK11/5/1996 11/26/1996
Print Pending Permit.LaserJet4  11/26/1996 PEND
files
Plan Reviewer's activity  11/26/1996 PEND
reviewed plans yesterday, telephone Jerry Fraizer about need to place Occupancy Separation wall between service and warehouse and discuss preliminary faxed revisions, mark-up plans, prepare correction list, input to Plan analysist for review, Fax corrections to Engineer and Contractor, Input to Tidemark, forward to Fire.
Plan resubmittals requested11/26/1996 11/26/1996
Telephone call  11/25/1996 PEND
called Jerry Fraizer about Occupancy separation wall, and 1-hr rated openings.
Routing - PLANNING10/28/1996 11/5/1996 FAIL
X-ref: CU-107-89,DR-94-89. Needs design review modification. Okay per HWG to place a letter in CU file regarding design review modification rather than requiring conditional use modification also. Reviewed by GRH & MS.
Plans ACCEPTED BY PLAN CHECK  11/5/1996 PEND
PRELIMINARY REVIEW REQUIRING INFORMATION BEFORE PLAN CHECK CAN BE PERFORMED.
Routing - PUBLIC WORKS10/25/1996 10/28/1996 PASS
Plan routing begun/TENANTS  10/25/1996
Route to PUBLIC WORKS and PLANNING then back to PLAN CHECK. After Plan Check route to FIRE DEPARTMENT.
Recd Pcfee & Taken To Pln CK  10/24/1996
Gay Receipt For Partial Pay  10/24/1996
Application received  10/24/1996