CHANGE STATUS TO (D) | | | 5/21/1997 | | |
|
|
|
|
INSP - Letter of compliance | 5/16/1997 | 5/16/1997 | 5/16/1997 | | PASS |
Russ Owen
|
|
|
/ / 407 - control #13455
|
INSP - Final | 5/15/1997 | 5/16/1997 | 5/16/1997 | A | PASS |
Russ Owen
|
|
|
CONTROL #13455 05/16/97 FNL -OK FINAL
|
INSP - Letter of compliance | 5/16/1997 | 5/16/1997 | 5/16/1997 | | PASS |
Russ Owen
|
|
|
/ / 407 - control #13455
|
INSP - Final | 4/11/1997 | 4/11/1997 | 4/11/1997 | P | FAIL |
Jim Storey
|
|
|
|
INSP - Energy code compliance | 1/17/1997 | 1/17/1997 | 1/17/1997 | | PASS |
Carl Dependahl
|
|
|
/ / 340 - PULLED PAPER FROM LITES, C/N OK
|
INSP - Framing/Rough-in | 1/16/1997 | 1/17/1997 | 1/17/1997 | A | PASS |
Carl Dependahl
|
|
|
01/17/97 340 - FRAME REINSPECT C/N OK
|
INSP - Framing/Rough-in | 1/16/1997 | 1/16/1997 | 1/16/1997 | P | PART |
Wes Worcester
|
|
|
FRAME REINSPECT
|
INSP - Energy code compliance | 1/14/1997 | 1/15/1997 | 1/15/1997 | P | CANC |
Alan Hauser
|
|
|
01/15/97 350 - to be done by #340
|
INSP - Framing/Rough-in | 1/15/1997 | 1/15/1997 | 1/15/1997 | | FAIL |
Carl Dependahl
|
|
|
/ / 340 - KEEP C/N, PONY WALL DETAILS NOT FIXED, POINT LOAD MISSED, PU CANLITES
|
INSP - Energy code compliance | 1/15/1997 | 1/15/1997 | 1/15/1997 | | PART |
Carl Dependahl
|
|
|
/ / 340 - WALL INS OK, NEED PULL PAPER FROM CAN LITES
|
INSP - Framing/Rough-in | 1/10/1997 | 1/13/1997 | 1/13/1997 | P | PART |
Carl Dependahl
|
|
|
FRAME REINSPECT
|
INSP - Framing/Rough-in | 1/13/1997 | 1/13/1997 | 1/13/1997 | | PASS |
Carl Dependahl
|
|
|
01/13/97 340 - FRAME REINSPECT, SHOWED ENG'G, INSTALLED FIREBLOCKS; OK T
|
INSP - Framing/Rough-in | 1/9/1997 | 1/10/1997 | 1/10/1997 | A | FAIL |
Carl Dependahl
|
|
|
01/10/97 340 - C/N, NEED FIREBLKS, AIR SEAL, ENG'G FIX FOR TRUSSES. NO I
|
Telephone call | | | 11/15/1996 | | |
|
|
|
TOLD SECRETARY PERMIT READY
|
Inspection Record Card- Bld | | | 11/15/1996 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 11/15/1996 | | |
|
|
|
|
Plan assigned to (340) | 11/8/1996 | | 11/14/1996 | | PASS |
|
|
|
plan check #843 11/14/96 15:13:01 340 - this action updated by action script from <<>> in Case No. BLD96-2991
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/14/1996 | | PASS |
|
|
|
ASAP
|
Telephone call | | | 11/14/1996 | | PASS |
|
|
|
CALL TO JOE W/ OEI
|
testing condition printout | | | 11/14/1996 | | PASS |
|
|
|
|
Print permit w/o conditions | | | 11/14/1996 | | PASS |
|
|
|
|
(F) Reprint permit | | | 11/8/1996 | | |
|
|
|
|
Plan assigned to (DJO) | 11/5/1996 | | 11/8/1996 | | PEND |
Dan Overy
|
|
|
|
Routing - PLANNING | 11/7/1996 | | 11/7/1996 | | PASS |
|
|
|
Approved by GRH.
|
Routing - PUBLIC WORKS | 11/5/1996 | | 11/7/1996 | | PASS |
|
|
|
|
Application received | | | 11/5/1996 | | |
|
|
|
|
Routing - PLAN CHECK | 11/7/1996 | | | | PEND |
|
|
|
|