INSP-Sprinkler Rough-in/Hydro | 10/1/1997 | 10/1/1997 | 10/1/1997 | P | PASS |
Rick Jackson
|
|
|
MOTEL 6--FIRE LIFE SAFETY Follow up inspection of open c/n items.
|
INSP - Final | 9/30/1997 | 9/30/1997 | 10/1/1997 | P | PART |
Jim Storey
|
|
|
09/30/97 301 - perm. occ ok upon plm. and fire sign offs
|
INSP - Final | 5/20/1997 | 5/21/1997 | 5/21/1997 | A | NR |
Jim Storey
|
|
|
05/21/97 301 -
|
INSP-Final Inspection | 5/21/1997 | 5/21/1997 | 5/21/1997 | P | FAIL |
|
|
|
alarms not tested, handicap rooms alarm entire building, fe cabinets locked, understair storage not prot by 1 hr, no plans on site, KNOX BOX??
|
INSP - Foundation | 5/20/1997 | 5/20/1997 | 5/20/1997 | P | PASS |
Jim Storey
|
|
|
05/20/97 301 - REBAR IN FOUNDATION OF POOL HOUSE FRMS-OK FORMS-REBAR
|
INSP - Footings | 5/15/1997 | 5/16/1997 | 5/16/1997 | P | PASS |
Jim Storey
|
|
|
05/16/97 301 - MOTEL 6/ POOL ROOM/ EARLY PM PLEASE/ DON BUCKMASTER/ 322- CFRM-OK CEILING FRAMINGO CALL YOU TO SCHEDULE TIME
|
INSP - Ceiling grid | 4/21/1997 | 4/22/1997 | 4/22/1997 | A | PASS |
Jim Storey
|
|
|
04/22/97 301 - SCLG-OK SUSPENDED CEILING
|
INSP - Ceiling grid | 4/21/1997 | 4/21/1997 | 4/21/1997 | | FAIL |
Jim Storey
|
|
|
/ / 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED n/r for complet insp and menb protection must be in place before tile cover.
|
INSP - Ceiling grid | 4/21/1997 | 4/21/1997 | 4/21/1997 | P | FAIL |
Jim Storey
|
|
|
T-BAR GRID and membrane protection not complet.
|
INSP - Framing/Rough-in | 3/31/1997 | 4/1/1997 | 4/1/1997 | A | PART |
Jim Storey
|
|
|
04/01/97 301 - FRAM-OK FRAMING ADA ROOMS 3 OUT OF 4
|
INSP - Carpentry | 3/18/1997 | 3/18/1997 | 3/18/1997 | P | PASS |
Jim Storey
|
|
|
03/18/97 301 - fire caulking GWB -OK SHEETROCK NAILING fire stopping at bath 1 st floor c wing ok
|
INSP - Carpentry | 3/13/1997 | 3/14/1997 | 3/14/1997 | A | PART |
Jim Storey
|
|
|
03/14/97 301 - FIRE CAULK WIP -WORK IN PROGRESS ok valve assembly 2nd floor.
|
INSP - Carpentry | 3/10/1997 | 3/11/1997 | 3/11/1997 | A | PASS |
Jim Storey
|
|
|
03/11/97 301 - putty pads in place on upper units a wing ok
|
INSP - Final | 3/10/1997 | 3/10/1997 | 3/10/1997 | P | PART |
|
|
|
section 1 temp, ok,back of card signed
|
INSP-Conference | 3/10/1997 | 3/10/1997 | 3/10/1997 | P | PART |
|
|
|
return alarm plans, not complete, grinnel to provide batt and volt drop calcs, removing h/c detectors from building alarm
|
90 day tracking............. | | 12/4/1996 | 3/4/1997 | | PEND |
|
|
|
|
Print Occupancy Form | | | 2/14/1997 | | |
|
|
|
|
Print Occupancy Form | | | 2/14/1997 | | |
|
|
|
|
Print Occupancy Form | | | 2/14/1997 | | |
|
|
|
|
INSP - Carpentry | 2/12/1997 | 2/13/1997 | 2/13/1997 | A | PASS |
Jim Storey
|
|
|
02/12/97 301 - FIRE STOP (AFTR 9 A.M.) FRBL-OK FIREBLOCKING
|
INSP - Carpentry | 2/7/1997 | 2/10/1997 | 2/10/1997 | P | PASS |
Jim Storey
|
|
|
02/10/97 301 - FIRE CAULKING, ETC. GWB -OK SHEETROCK NAILING
|
INSP - Carpentry | 2/7/1997 | 2/7/1997 | 2/7/1997 | | PASS |
Jim Storey
|
|
|
02/07/97 301 - FIRE STOPS FRWL-RATED WALL CONST. OK
|
INSP - Temporary occupancy | 2/5/1997 | 2/5/1997 | 2/5/1997 | P | NR |
Jim Storey
|
|
|
02/05/97 301 - n/r
|
INSP - Final | 2/5/1997 | 2/5/1997 | 2/5/1997 | A | FAIL |
|
|
|
issue c/n after researching plans and talking with dick pierce. wing "C" only inspected. lots of problems...rated doors not installed to corridor, deadbolts on exit doors, alarms, exit signs, fire extinguishers locked up, storage under stairs.
|
INSP - Final | 2/4/1997 | 2/4/1997 | 2/4/1997 | P | FAIL |
|
|
|
exit hardware wrong, alarms not upgraded in c wing as required, want to do in phases but not noted on plans, no emergency power for exit lights..no plan review comments, will look up in vault
|
INSP - Carpentry | 1/6/1997 | 1/6/1997 | 1/6/1997 | P | PART |
Jim Storey
|
|
|
01/06/97 301 - fire stopping on first 6/lower and 4 upper ok at shower v
|
INSP - Carpentry | 1/3/1997 | 1/6/1997 | 1/6/1997 | A | PART |
Jim Storey
|
|
|
01/06/97 301 - fire stopping first group of rooms 3 n top/bottom west en assembly
|
INSP-Conference | 1/3/1997 | 1/3/1997 | 1/3/1997 | | PASS |
|
|
|
/ / 405 - reviewed alarm system requirements w/ contractor. need hall H/S. rooms need single sta smokes, ada romms need h/s.
|
INSP - Framing/Rough-in | 12/30/1996 | 12/30/1996 | 12/28/1996 | P | NR |
|
|
|
12/30/96 338 -
|
Issue PAID IN FULL permit | | | 12/27/1996 | | |
|
|
|
|
Inspection Record Card- Bld | | | 12/24/1996 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 12/24/1996 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/24/1996 | | PASS |
|
|
|
ISSUED
|
Print Occupancy Form | | | 12/24/1996 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 12/24/1996 | | PASS |
|
|
|
FILES
|
Plan assigned to (PRP) | 12/5/1996 | | 12/24/1996 | | PASS |
|
|
|
12/24/96 08:51:29 PRP - this action updated by action script from <<>> in Case No. BLD96-3234
|
Routing - FIRE | 12/17/1996 | | 12/24/1996 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 12/24/1996 | | PASS |
|
|
|
review plans, prepare correction list, fax to architect, forward to fire dept. wait for resubs. REVIEW RESUBS (AS ADDENDUM), ASSEMBLE INTO PLANS, APPROVE AND ISSUE
|
Plan resubmittals received | 12/24/1996 | | 12/18/1996 | | |
|
|
|
|
Routing - PLAN CHECK | 12/11/1996 | | 12/17/1996 | | |
|
|
|
|
Plan resubmittals requested | 12/17/1996 | | 12/17/1996 | | |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 12/16/1996 | | PEND |
|
|
|
RECEIVED FROM CIRCULATION OF PW AND PLANNING. START REVIEW.
|
Routing - PLANNING | 12/10/1996 | | 12/11/1996 | | PASS |
|
|
|
Approved by MS.
|
Routing - PUBLIC WORKS | 12/5/1996 | | 12/10/1996 | | PASS |
|
|
|
|
Plan routing begun/TENANTS | | | 12/5/1996 | | |
|
|
|
Route to PUBLIC WORKS, PLANNING then back to PLAN CHECK. After Plan Check route to FIRE DEPARTMENT.
|
Gay Receipt For Partial Pay | | | 12/4/1996 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 12/4/1996 | | |
|
|
|
|
Application received | | | 12/4/1996 | | |
|
|
|
|
Routing - PLAN CHECK | 12/24/1996 | | | | |
|
|
|
|