Permanent Occupancy | | 6/24/1997 | 6/24/1997 | | DONE |
|
|
|
|
INSP - Final | 6/23/1997 | 6/24/1997 | 6/24/1997 | P | PASS |
Tom Arcoraci
|
|
|
FINAL C.O.
|
INSP-Final Inspection | 6/23/1997 | 6/24/1997 | 6/24/1997 | A | PASS |
|
|
|
NO OCC CARD ON SITE, SIGNED INSPECTION RECORD CARD
|
Print Occupancy Form | | | 6/24/1997 | | |
|
|
|
|
Permanent occupancy | | | 6/24/1997 | | PASS |
|
|
|
Perm. Occ. Cert. #6900 issued 6-24-97 to United Brands International.
|
INSP - Framing/Rough-in | 6/5/1997 | 6/5/1997 | 6/4/1997 | P | PASS |
|
|
|
06/05/97 333 - FRAM-OK FRAMING
|
Telephone call | | | 6/4/1997 | | PASS |
|
|
|
NICOLE WILL LET HIM KNOW ITS READY
|
Print Pending Permit.LaserJet4 | | | 6/4/1997 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/4/1997 | | PASS |
|
|
|
issue
|
Issue PAID IN FULL permit | | | 6/4/1997 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 6/4/1997 | | PASS |
|
|
|
files
|
Inspection Record Card- Bld | | | 6/4/1997 | | |
|
|
|
|
Plan Reviewer's activity | | | 6/4/1997 | | PASS |
|
|
|
Spoke with Marlene about corridor(s) in this building and she said these corridors are not needed to fire resistive rated corridors and should comply to code as they are. An indepth study and upgrading was done in past years that should have taken care of the problem.
|
Plan assigned to (PRP) | 5/12/1997 | | 6/4/1997 | | PASS |
|
|
|
06/04/97 11:49:39 PRP - this action updated by action script from <<>> in Case No. BLD97-1251
|
Print Pending Permit.LaserJet4 | | | 5/22/1997 | | PEND |
|
|
|
files
|
Plan Reviewer's activity | | | 5/21/1997 | | PEND |
|
|
|
REVIEWED PLANS, FICHE FILES, HARD FILE HISTORY, PREPARED SHORT ANALYSIS, CALLED MARY BOLEN FOR CLEARIFICATION OF TENANTS FUNCTION AND ROOM USES. LEFT MESSAGE. NOT IN OFFICE. Called Mary (5/22) again. Does not know about corridor. Informed her the corrections will require varification of rated corridor construction before permit issuance.
|
Telephone call | | | 5/21/1997 | | PEND |
|
|
|
TO MARY BOLEN, BRS ARCH
|
Routing - PUBLIC WORKS | 5/13/1997 | | 5/14/1997 | | PASS |
|
|
|
|
Plan routing begun/TENANTS | | | 5/12/1997 | | |
|
|
|
Route to PUBLIC WORKS then back to PLAN CHECK. Provide a copy of the plan review and permit to the Fire Department for their records.
|
Gay Receipt For Partial Pay | | | 5/12/1997 | | |
|
|
|
|
Plan assigned to (MYS) | 5/12/1997 | | 5/12/1997 | | |
Marlene Southard
|
|
|
|
Application received | | | 5/9/1997 | | |
|
|
|
|
Routing - PLAN CHECK | 5/14/1997 | | | | |
|
|
|
|