Permit NumberBLD97-01316
StatusFinaled
Name MED NOW MEDICAL SUPPLY
Site Address 6010 W FRANKLIN RD
Project Name 
Customer Number 
ePlanReviewNo
Description
To remodel an existing 10,650 sq.ft. warehouse to convert to medical and furniture supplier office and warehouse per approved plans on file. This building to be fully fire sprinklered per NFPA #13 as requlated by the fire department, under this permit. Work to include remodel and renovation of southwest corner of building for new store front, upgrade exterior, provide new paving and landscaping per DR-76-97 and install new suspended ceiling system, construct interior non-bearing non-rated walls to divide up space for storage, offices, sales room and two accessible restrooms. Provide one-hour rated corridor to exit on east side of building. Construct new accessible ramp. P.C.(#276-97)RMH
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 12/22/199712/22/1997 DONE
Details
INSP - Final12/22/199712/22/199712/22/1997 PASS
Final
Permanent occupancy  12/22/1997 PASS
Perm. Occ. Cert. #7082 issued 12-22-97 to Med Now Medical Supply.
INSP - Conference12/11/199712/11/199712/11/1997 PASS
Details
/ / 338 - contractor called to schedule time of inspection (we do not
INSP - Final12/10/199712/11/199712/11/1997APART
Details
12/11/97 338 - MED NOW made ok
INSP - Final12/10/199712/10/199712/10/1997PCANC
Details
MED NOW CANCELED PER CONTRACTOR, PERRY OFF, WANTS TO RESCHEDULE WITH PERRY FOR TOMMORROW
INSP-Final Inspection12/5/199712/8/199712/8/1997PPASS
DetailsRick Jackson
MED NOW all items on c/n complied
INSP-Final Inspection11/4/199711/6/199711/6/1997APART
DetailsJoe Tawney
11/06/97 406 - FINAL OK FOR TEMP OCC DOOR HOLD OPEN NFPA 72
Routing for occupancy11/10/1997 11/6/1997 PASS
Approved by: Carol A. Montgomery (DRH97-0076)
INSP - Framing/Rough-in10/28/199710/29/199710/29/1997PPASS
Details
CEILING GRID MADE OK
INSP-Final Inspection10/29/199710/29/199710/29/1997PNR
DetailsJoe Tawney
10/29/97 406 - PRE FINAL CONFERENCE NOT YET READY FOR FINAL
INSP-Sprinkler Rough-in/Hydro10/23/199710/23/199710/23/1997PPART
DetailsJoe Tawney
10/23/97 406 - BETWEEN 2 AND 2:30 OK ON UNDERGROUND FLUSH AND SPKLR ROUGH IN
INSP - Final11/5/199711/6/199710/6/1997PPASS
DetailsTom Arcoraci
JERRY WILL CALL TO SCHEDULE WITH WHOMEVER GETS THIS TEMP OCC OK
INSP - Foundation9/22/19979/22/19979/22/1997PPASS
Details
09/22/97 338 - made ok with sp insp ok
INSP - Set-back9/9/19979/9/19979/9/1997 PASS
Details
/ / 338 - made ok for the loading dock with sp insp approval
INSP - Footings9/9/19979/9/19979/9/1997PPASS
Details
09/09/97 338 - made ok
INSP - Framing/Rough-in9/5/19979/5/19979/5/1997 PASS
Details
/ / 338 - ok to with the ele approval
INSP - Footings9/4/19979/5/19979/5/1997APASS
Details
09/05/97 338 - footing made ok
INSP - Framing/Rough-in9/5/19979/5/19979/5/1997PPART
Details
09/05/97 338 - made ok to cover with plmg walls left open for completion inspection
Issue PAID IN FULL permit  8/26/1997
Inspection Record Card- Bld  8/26/1997
Telephone call  8/26/1997
PERMIT READY
Print Occupancy Form  8/26/1997
PLANS/APPL TAKEN TO FRONT DESK  8/26/1997 PASS
(F) Reprint permit  8/26/1997
Plan assigned to (R_H)5/16/1997 8/25/1997 PASS
Details
08/25/97 10:38:34 R_H - this action updated by action script from <<>> in Case No. BLD97-1316
Plan Reviewer's activity  8/25/1997 PASS
Reviewed resubmittal. Ready to issue.
Print Pending Permit.LaserJet4  8/25/1997 PASS
Routing - FIRE8/14/1997 8/22/1997 PASS
90 day tracking............. 5/15/19978/13/1997 PEND
Plan Reviewer's activity  8/4/1997 FAIL
Reviewed revised plans. Faxed corrections needed to architect.
Routing - PLANNING7/30/1997 8/1/1997 PASS
X-REF: DRH97-0076. APPROVED BY MGS.
Routing - PLAN CHECK7/25/1997 7/30/1997
Plan Reviewer's activity  7/29/1997 FAIL
Routed plans back to planing with resubmittal of landscaping.
Routing - FIRE7/17/1997 7/25/1997 FAIL
Plan Reviewer's activity  7/17/1997 FAIL
Mailed corrections to architect. routed to fire department.
Routing - PLAN CHECK7/16/1997 7/17/1997
Routing - PLANNING7/15/1997 7/15/1997 FAIL
X-REF: DR-76-97. PLANS DO NOT COMPLY WITH DR-76-97, CONDITION #1D 5'0" LANDSCAPE PARKING LOT SETBACK.
Routing - PLUMBING7/9/1997 7/14/1997 PASS
Routing - PUBLIC WORKS6/26/1997 7/8/1997 PASS
Routing Off Site - A.C.H.D5/16/1997 6/25/1997 PASS
CONTACTED PAT MCKEEGANS OFFICE TO TAKE PLANS TO ACHD.
Plan routing begun/TENANTS  5/16/1997
Route to ADA COUNTY HIGHWAY DISTRICT, PUBLIC WORKS, PLUMBING, PLANNING then to PLAN CHECK. After Plan Check route to FIRE DEPARTMENT.
Plan assigned to (MYS)5/15/1997 5/16/1997
DetailsMarlene Southard
Application received  5/15/1997
Recd Pcfee & Taken To Pln CK  5/15/1997
Routing - PLAN CHECK8/1/1997  
Routing - PLAN CHECK8/24/1997