Permit Information
Permit NumberBLD97-01324
StatusFinaled
Name C W MOORE APARTMENTS
Site Address 450 W GROVE ST
Project NameC W MOORE APARTMENTS
Customer Number 
ePlanReviewNo
Description
C.W. MOORE APARTMENTS * TO CONSTRUCT A NEW THREE STORY, 47 DWELLING UNIT (46 ONE BEDROOM & 1 TWO BEDROOM), WOOD FRAME APARTMENT BUILDING OVER A ONE STORY MASONRY AND CONCRETE ENCLOSED PARKING GARAGE. THE PARKING GARAGE IS SEPARATED FROM THE APARTMENT BUILDING BY A THREE-HOUR FIRE-RESISTIVE OCCUPANCY SEPARATION. THE APARTMENT BUILDING IS FULLY FIRE SPRINKLED AND USED FOR ALLOWABLE AREA INCREASE. THE PARKING GARAGE IS NOT FIRE SPRINKLED. THIS PERMIT ALSO INCLUDES ALL RELATED SITE IMPROVEMENTS. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED REQUIREMENT LIST. DR#61-96/PC#290-97/JCM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  3/10/2004  
Permanent Occupancy 7/17/19987/17/1998 DONE
Details
Permanent occupancy  7/17/1998 PASS
Perm. Occ. Cert. #7322 issued 7-17-98 to C.W. Moore Apts.
INSP - Final7/16/19987/16/19987/16/1998PPASS
Details
07/16/98 333 - FNL -OK FINAL
INSP - Final7/15/19987/15/19987/15/1998PPART
Details
07/15/98 333 - signed for temp cn placed
INSP-Final Inspection7/15/19987/15/19987/15/1998APASS
DetailsRick Jackson
occ approved
INSP-Final Inspection7/14/19987/14/19987/14/1998PFAIL
DetailsRick Jackson
Scott ###-#### sprinkler head painted, room detector not working with test button
Code Occupancy Approval  7/14/1998 PASS
Meets requirements of plan. final signed.
Code Occupancy Approval  7/2/1998 PEND
Signed Temp Small amount of bark andcouple of sprinkler heads. When completed will sign PERM.
INSP - Final6/30/19987/1/19987/1/1998PPART
Details
07/01/98 333 - temp ok cn placed
Temporary occupancy  7/1/1998 PASS
Temp. Occ. Cert. #3648 issued 7-1-98 to the C W Moore Apts. (south side of bldg. only).
INSP-Alarm Testing6/30/19986/30/19986/30/1998PPART
DetailsRick Jackson
Scheduled by Hello!. Contact phone is [3420479]. sprinkler obstruction by lights in kitchen, NFPA 72 certificate, temp occ approved for south building only
INSP-Final Inspection6/29/19986/29/19986/29/1998PFAIL
DetailsRick Jackson
ADA room not complete, check elevator recall, CO detectors not installed, sprinkler head in riser room needed, recheck for alarm monitoring
INSP-Final Inspection6/25/19986/26/19986/26/1998PFAIL
DetailsRick Jackson
Scott ###-#### c/n issued for numerous items.
INSP - Framing/Rough-in6/24/19986/25/19986/25/1998AFAIL
Details
06/25/98 333 - aconference on final
INSP-Sprinkler Rough-in/Hydro6/9/19986/10/19986/10/1998APASS
DetailsRick Jackson
hydro testing/ ###-#### jenifer hydro okay. heads installed in stairs. riser room has numerous pentrations - doesn't meet 1 hour - they aren't finished with room
INSP - Framing/Rough-in6/8/19986/8/19986/8/1998PPART
Details
06/08/98 333 - conference Scott ###-#### this morning confrerence about attic acess
INSP-Sprinkler Rough-in/Hydro5/29/19985/29/19985/29/1998PPART
Details
Scheduled by Hello!. Contact phone is [3420479]. the wet system has been fully tented, ok to insulate. The dry pipe penetrations through the attic negate the use of the overbuild sheathing as a draft stop because they are oversized.
INSP-Sprinkler Rough-in/Hydro5/27/19985/27/19985/27/1998PFAIL
DetailsRick Jackson
Scheduled by Hello!. Contact phone is [3420479]. not tented properly. reinspect when ready
INSP - Framing/Rough-in5/12/19985/13/19985/13/1998AFAIL
Details
05/13/98 333 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Framing/Rough-in4/21/19984/22/19984/22/1998APASS
Details
04/22/98 333 - 4th floor ok
INSP - Framing/Rough-in4/20/19984/20/19984/20/1998PFAIL
Details
04/20/98 333 - cn placed
INSP - Framing/Rough-in4/15/19984/16/19984/16/1998PPART
Details
04/16/98 333 - third floor north ok
INSP-Sprinkler Rough-in/Hydro4/16/19984/16/19984/16/1998PFAIL
DetailsRick Jackson
###-####/jENNIFER not tented over ends of sprinkler piping
INSP - Wall cover4/15/19984/15/19984/15/1998 PASS
Details
/ / 333 - SOUTH SIDE OK
INSP - Framing/Rough-in4/14/19984/14/19984/14/1998PPASS
Details
04/14/98 333 - 2nd floor ok
INSP - Framing/Rough-in4/8/19984/9/19984/9/1998APART
Details
04/09/98 333 - south tower ok
INSP - Framing/Rough-in4/8/19984/8/19984/8/1998 FAIL
Details
04/08/98 333 - cn not made
INSP - Framing/Rough-in4/7/19984/8/19984/8/1998APASS
Details
south side ok
INSP - Framing/Rough-in4/7/19984/7/19984/7/1998PFAIL
Details
04/07/98 333 - cn not made
INSP - Framing/Rough-in4/6/19984/6/19984/7/1998PPART
Details
04/06/98 333 - 3rd floor ok
INSP - Framing/Rough-in4/1/19984/2/19984/2/1998APART
Details
04/02/98 333 - EXPLAINED CN
SUPER- Supervisor's review3/31/19983/31/19983/31/1998 PEND
Carpentry walk through.
INSP - Framing/Rough-in3/31/19983/31/19983/31/1998PFAIL
Details
03/31/98 333 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP-Sprinkler Rough-in/Hydro3/17/19983/17/19983/17/1998APART
DetailsRick Jackson
attic rough-in okay. Shilo informed of requirement for inspector to check tenting of piping going through unheated attic area.
INSP-Supply line flush3/17/19983/17/19983/17/1998PPASS
DetailsRick Jackson
INSP-Supply line flush3/12/19983/17/19983/17/1998ANR
DetailsRick Jackson
shilo - cw moore United Water wasn't requested to open key valve. will request a flush when UW can make it.
INSP - Framing/Rough-in3/17/19983/17/19983/17/1998 PART
Details
/ / 333 - MET W / SCOTT ABOUT FIRESTOPPING
INSP - Framing/Rough-in3/10/19983/11/19983/11/1998PFAIL
Details
03/11/98 333 - need firestops scott ###-####
INSP - Framing/Rough-in3/3/19983/4/19983/4/1998APART
Details
03/04/98 333 - fir downs ok to cover SCOTT ###-####
INSP-Sprinkler Rough-in/Hydro3/3/19983/3/19983/3/1998APASS
DetailsRick Jackson
2,3,4th floors approved for cover. dry system in attic not finished and not approved for cover or tenting.
INSP - Final3/2/19983/3/19983/3/1998AFAIL
Details
03/03/98 333 - not a final conference about 1 hour lids Scheduled by Hello!. Contact phone is [466
INSP - Framing/Rough-in2/23/19982/24/19982/24/1998APART
Details
02/24/98 333 - reviewed 1hr requirementsSCOTT ###-####
INSP - Framing/Rough-in2/12/19982/12/19982/12/1998PPART
Details
02/12/98 333 - talked sbout firestopping ###-#### scott
INSP-Sprinkler Rough-in/Hydro2/10/19982/11/19982/11/1998APASS
DetailsRick Jackson
###-#### SHELLIE 2nd floor only rough-in okay
INSP - Framing/Rough-in2/4/19982/9/19982/9/1998APART
Details
02/09/98 333 - pre frame
INSP - Framing/Rough-in2/3/19982/4/19982/4/1998APART
Details
02/04/98 333 - pre frame
INSP - Framing/Rough-in12/15/199712/15/199712/15/1997APART
Details
12/15/97 333 - first floor pour ok
INSP - Final12/12/199712/15/199712/15/1997AFAIL
Details
12/15/97 333 - first floor pour ok
INSP - Framing/Rough-in12/5/199712/8/199712/8/1997APART
Details
12/08/97 333 - deck STEEL WELDING
INSP - Conference12/2/199712/3/199712/3/1997PPASS
Details
12/03/97 333 - talked about welds for deck ul system
INSP - Footings10/15/199710/16/199710/16/1997ANR
DetailsJim Storey
10/16/97 301 - n/r special insp. pending recall when job is ready for gr
INSP - Footings10/13/199710/14/199710/14/1997APASS
Details
10/14/97 333 - around 11:00 please FDN -OK FOUNDATION one half
INSP - Foundation10/9/199710/10/199710/10/1997APASS
Details
10/10/97 333 - WOULD PREFER AROUND 11:30 PLEASE FTG -OK FOOTING
INSP - Footings10/7/199710/8/199710/8/1997PPASS
Details
10/08/97 333 - west half ok
(F) Reprint permit  10/8/1997
INSP - Footings10/7/199710/7/199710/7/1997PPART
Details
10/07/97 333 - FTG -OK FOOTING
Print Occupancy Form  10/6/1997
Inspection Record Card- Bld  10/6/1997
Print Occupancy Form  9/29/1997
Telephone call  9/29/1997
TALKED TO RECEP. AT CSHQA - WILL CALL BACK
Inspection Record Card- Bld  9/29/1997
Issue PAID IN FULL permit  9/29/1997
Routing - PLAN CHECK9/23/1997 9/26/1997 PASS
PLANS/APPL TAKEN TO FRONT DESK  9/26/1997 PASS
Routing - PLAN CHECK7/30/1997 9/26/1997 PASS
package #2
Routing - PLAN CHECK9/8/1997 9/26/1997 PASS
RESUBS #1 FROM CH2MHILL ( PACKAGE #3)
Plan assigned to (JCM)6/20/1997 9/26/1997 PASS
DetailsJohn Menard
Routing - PLUMBING8/26/1997 9/17/1997 PASS
PACKAGE #1
Routing Off Site - A.C.H.D5/22/1997 9/15/1997 PASS
PACKAGE #4 CONTACTED TERESA FROM OTIS LEMMON'S OFFICE AT ###-#### TO TAKE PLANS OUT TO ACHD. ACHD FEES PAID. CERTIFICATE #97-1957 -JCM
Routing Off Site - STRUCTURAL8/26/1997 9/8/1997
RESUBS SENT TO CH2MHILL VIA PDQ. STRUCTURAL REVIEW LETTER AND DRAWINGS RETURNED FROM CH2MHILL AND GIVEN TO JOHN M.
Routing - PLAN CHECK6/17/1997 8/26/1997 PEND
PACKAGE #3
Plan resubmittals requested  8/26/1997 PEND
Plan resubmittals received  8/13/1997 PEND
Routing - PLANNING6/6/1997 7/29/1997 PASS
PACKAGE #2 X-REF: DR-61-96. APPROVED BY TKW.
Routing - FIRE7/9/1997 7/15/1997 PASS
PACKAGE #1
Plan resubmittals requested  7/8/1997 PEND
SENT CORRECTION LIST TO OTIS LEMMON ALONG WITH A COPY OF THE CORRECTION LIST FROM CH2MHILL.
Plan assigned to (RGG)5/21/1997 6/20/1997
Routing Off Site - STRUCTURAL5/22/1997 6/17/1997
PACKAGE #3 CONTACTED PDQ TO TAKE PLANS OUT CH2MHILL
Routing - PUBLIC WORKS5/22/1997 6/5/1997 PASS
PACKAGE #2
Routing - ELECTRICAL5/28/1997 5/29/1997 PASS
NOT APPLICABLE VIEWED BY ELECTRICAL PACKAGE #1
Routing - PLUMBING5/22/1997 5/27/1997 FAIL
PACKAGE #1
Plan routing begun/NEW & ADDTN  5/22/1997
SEE ACTION 007 PEND.
Plans ACCEPTED BY PLAN CHECK  5/22/1997 PEND
ON HOLD FOR PACKAGE #2 REQUIRES 2 SETS OF ELEVATION SHEETS A4.1, A4.2, AND A4.3 LEFT MESSAGE FOR OTIS LEMMON OF THIS NEED. KMM 5-21-97 SPOKE WITH TERESA FROM LEMMON'S OFFICE SHE IS BRINGING ELEV. TO ME 5-22-97. I AM ROUTING PACKAGES #1,3,AND4. WILL ROUTE #2 WHEN I RECEIVED ELEV. KMM RECEIVED ELEVATIONS. KMM 5-22-97
Plans ACCEPTED BY PLAN CHECK  5/22/1997
SEE ACTION 007 PEND
Received Certificate of Value  5/21/1997 PASS
Plan assigned to (MYS)5/15/1997 5/21/1997
DetailsMarlene Southard
Application received  5/15/1997