Case Summary (BLD) | | | 7/23/2010 | | DONE |
|
|
|
|
DOC - Permit Finaled | 1/17/2001 | 1/17/2001 | 1/17/2001 | P | PASS |
Russ Owen
|
|
|
Added by Inspector: 407 On 1/17/2001 4:49:53 PM
|
BLD-Final | 11/3/2000 | 11/3/2000 | 11/3/2000 | A | PASS |
Joe Tawney
|
|
|
Added by Inspector: 406 On 11/3/2000 Reinsp OK for permanant occupancy
|
Code Occupancy Approval | | | 5/2/2000 | | PASS |
|
|
|
Meets compliance with DR - PASS
|
BLD-Final | 3/16/2000 | 3/16/2000 | 3/16/2000 | A | FAIL |
Joe Tawney
|
|
|
Reinsp. fail smoke/fire damper still not operable.
|
FIRE-Final Inspection | 3/15/2000 | 3/15/2000 | 3/15/2000 | P | FAIL |
Joe Tawney
|
|
|
###-#### Reinsp. fail smoke/fire damper failed to operate no inspection opening. 3/16/00 1:40:38 PM
|
INSP - Final | 12/14/1998 | 12/14/1998 | 12/14/1998 | | FAIL |
Joe Tawney
|
|
|
/ / 406 - REINSP FAIL INSTALL F/S DAMPER WITH DETECTION. ALL ELSE OK
|
Fee Review-notes | 10/9/1998 | | 11/18/1998 | | |
|
|
|
|
INSP - Final | 10/8/1998 | 10/8/1998 | 10/8/1998 | | FAIL |
Joe Tawney
|
|
|
/ / 406 - FINAL FAIL S/F DAMPER DOOR HDWRE SMOKE DETECTORS
|
Print Occupancy Form | | | 10/8/1998 | | |
|
|
|
|
INSP - Framing/Rough-in | 10/6/1997 | 10/6/1997 | 10/6/1997 | P | NR |
|
|
|
10/06/97 338 - out of time #1 10-07-97
|
INSP - Conference | 10/6/1997 | 10/6/1997 | 10/6/1997 | | PASS |
|
|
|
/ / 338 - OTH-OTHER AGENCIES NOT APPROVED ok to stare hanging the sheetrock in non effective areas
|
INSP - Framing/Rough-in | 10/1/1997 | 10/1/1997 | 10/1/1997 | | PART |
|
|
|
/ / 338 - ok to insulate only. heating correction in force
|
INSP - Framing/Rough-in | 9/30/1997 | 9/30/1997 | 9/30/1997 | P | NR |
|
|
|
10/01/97 338 - OTH-OTHER AGENCIES NOT APPROVED
|
INSP - Conference | 9/17/1997 | 9/17/1997 | 9/17/1997 | P | PASS |
|
|
|
09/17/97 338 - made ok
|
INSP - Conference | 9/15/1997 | 9/15/1997 | 9/15/1997 | P | PASS |
|
|
|
09/15/97 338 - with bruce harris made ok framing questions 1.5 hours
|
INSP - Foundation | 9/4/1997 | 9/4/1997 | 9/4/1997 | | PASS |
|
|
|
/ / 338 -
|
INSP - Wall cover | 9/3/1997 | 9/4/1997 | 9/4/1997 | A | CANC |
|
|
|
09/04/97 338 - TIS IS TO BR FOR A FOUNDATION
|
INSP - Footings | 9/2/1997 | 9/2/1997 | 9/2/1997 | P | PASS |
|
|
|
09/02/97 338 - MASN-REBAR OK FTG -OK FOOTING
|
(F) Reprint permit | | | 8/26/1997 | | |
|
|
|
|
(F) Reprint permit | | | 8/20/1997 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/20/1997 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/19/1997 | | PASS |
|
|
|
|
Print Occupancy Form | | | 8/19/1997 | | |
|
|
|
|
Inspection Record Card- Bld | | | 8/19/1997 | | |
|
|
|
|
Telephone call | | | 8/19/1997 | | |
|
|
|
CALLED TRACEY PEARSONS PERMIT READY ###-####
|
Plan assigned to (R_H) | 6/18/1997 | | 8/18/1997 | | PASS |
|
|
|
08/18/97 16:03:25 R_H - this action updated by action script from <<>> in Case No. BLD97-1351
|
Print Pending Permit.LaserJet4 | | | 8/18/1997 | | PASS |
|
|
|
|
Waiting for Cert. of Value | | | 8/18/1997 | | PASS |
|
|
|
Called Tracey Persons left message that permit could be issued as soon as I receive a Final Certificate of Value.
|
90 day tracking............. | | 5/19/1997 | 8/17/1997 | | |
|
|
|
|
Routing - PLUMBING | 8/4/1997 | | 8/7/1997 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 8/1/1997 | | FAIL |
|
|
|
Recieved plumbing resubmittals/Routed back to plumbing for review.
|
Routing - PLAN CHECK | 6/18/1997 | | 6/23/1997 | | |
|
|
|
|
Plan Reviewer's activity | | | 6/23/1997 | | FAIL |
|
|
|
Faxed required corrections to architect.
|
Routing - ELECTRICAL | 6/16/1997 | | 6/18/1997 | | |
|
|
|
|
Plan assigned to (RGG) | 5/21/1997 | | 6/18/1997 | | |
|
|
|
This will be Ron Hill's project.
|
Routing - PLANNING | 6/11/1997 | | 6/12/1997 | | PASS |
|
|
|
X-REF: DR-29-96. APPROVED BY MGS & RC.
|
Routing - PLUMBING | 6/6/1997 | | 6/11/1997 | | FAIL |
|
|
|
|
Routing - PUBLIC WORKS | 5/30/1997 | | 6/6/1997 | | FAIL |
|
|
|
REQUIRES PROOF OF LEGAL LAND DIVISION.
|
Plans ACCEPTED BY PLAN CHECK | | | 5/28/1997 | | PASS |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 5/28/1997 | | PASS |
|
|
|
|
Plan assigned to (MYS) | 5/19/1997 | | 5/21/1997 | | |
Marlene Southard
|
|
|
|
Received Certificate of Value | | | 5/21/1997 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/19/1997 | | |
|
|
|
|
Application received | | | 5/19/1997 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | | | |
|
|
|
|
Routing - PLAN CHECK | 6/25/1997 | | | | FAIL |
|
|
|
Sent required corrections to arcitect.
|
Routing Off Site - A.C.H.D | 5/28/1997 | | | | |
|
|
|
CONTACTED TRACEY PERSONS AT ###-#### TO TAKE PLANS OUT TO ACHD.
|
Routing - PUBLIC WORKS | 8/7/1997 | | | | |
|
|
|
|