INSP - Final | 5/19/1998 | 5/19/1998 | 5/19/1998 | P | PASS |
Wes Worcester
|
|
|
05/19/98 342 - allan ###-####
|
INSP - Framing/Rough-in | 1/29/1998 | 1/29/1998 | 1/29/1998 | P | PASS |
Carl Dependahl
|
|
|
REINSP. FIREBLOCKS IN PLACE
|
INSP - Energy code compliance | 1/29/1998 | 1/29/1998 | 1/29/1998 | P | PASS |
Carl Dependahl
|
|
|
REINSP TO COMPLETE C/N. WALL INS OK.
|
INSP - Energy code compliance | 1/27/1998 | 1/28/1998 | 1/28/1998 | A | NH |
Wes Worcester
|
|
|
01/28/98 342 - ALLAN--###-#### OR ###-####
|
INSP - Conference | 1/28/1998 | 1/28/1998 | 1/28/1998 | | NH |
Wes Worcester
|
|
|
/ / 342 - called allan and reached answering machine
|
INSP - Framing/Rough-in | 1/16/1998 | 1/20/1998 | 1/20/1998 | P | PART |
Carl Dependahl
|
|
|
REINSP--JIM WILL CALL YOU TUES AM--###-#### 3:00 appt....REC'D RESUBMITTAL & TJI OK FOR BEAMS, OK TO INSUL; COMPLETE FIREBLOCKING.
|
INSP - Conference | 1/14/1998 | 1/13/1998 | 1/13/1998 | A | PASS |
Carl Dependahl
|
|
|
DISCUSSED C/N W/ JIM SALNAVE OF ID. PRE-CUT HOMES. NEED TJI REP OR ENG'S OK AND IDENTIFICATION OF BEAMS USED (FROM CANADA PER SALNAVE) AND COMPLETE RE-SUB FOR ROOF FRAME INCLUDING COMPLETE ENG'G. FAXED ENERGY CODE PATH TO IPH.
|
INSP - Conference | 1/12/1998 | 1/12/1998 | 1/12/1998 | A | PASS |
Carl Dependahl
|
|
|
W/ IDAHO TRUSS REP RE TRUSS ENG'G & IDENTIFICATION; NOT MANUF. FOR THIS JOB.
|
INSP - Framing/Rough-in | 1/7/1998 | 1/7/1998 | 1/7/1998 | P | CANC |
Russ Owen
|
|
|
TRAN TO 340
|
INSP - Framing/Rough-in | 1/7/1998 | 1/7/1998 | 1/7/1998 | P | FAIL |
Carl Dependahl
|
|
|
per BA...OWNER IS PERMIT HOLDER BUT PLAN IS FROM IDAHO PRE-CUT HMS OF EMMETT WHO ACTED AS ERECTION OR FRAMING CONTRACTOR. ROOF AND FLOOR NOT FRAMED PER PLAN, GAVE C/N & DISCUSSED W/ OWNER, NEED TJI APPROVAL FOR BEAMS CUT, ADDED, BORED, ETC. TRUSSES NOT STAMPED, ENG'G NOT COMPLETE. NEED RESUBMITTALS.
|
INSP - Framing/Rough-in | 12/26/1997 | 12/26/1997 | 12/26/1997 | P | NR |
Wes Worcester
|
|
|
12/26/97 342 - need truss eng, bcec not done, placing hangers, point loa completed...
|
INSP - Foundation | 10/27/1997 | 10/28/1997 | 10/28/1997 | P | PART |
Carl Dependahl
|
|
|
BASEMENT SLABS...gave owner verbal c/n to make sure all wood forms are removed from slab. ok to proceed.
|
INSP - Foundation | 10/8/1997 | 10/10/1997 | 10/10/1997 | A | NR |
Wes Worcester
|
|
|
LATE AM...no one there, bds not in place for basement
|
INSP - Conference | 10/10/1997 | 10/10/1997 | 10/10/1997 | P | PASS |
Wes Worcester
|
|
|
called and wanted me to stop back by
|
INSP - Foundation | 10/10/1997 | 10/10/1997 | 10/10/1997 | P | PASS |
Wes Worcester
|
|
|
pouring and looked ok
|
INSP - Foundation | 10/10/1997 | 10/10/1997 | 10/10/1997 | P | NR |
Wes Worcester
|
|
|
HE SAYS YOU SET IT UP FOR 3:00
|
INSP - Footings | 10/7/1997 | 10/8/1997 | 10/8/1997 | P | PASS |
Wes Worcester
|
|
|
WOULD PREFER 2:30
|
Issue PAID IN FULL permit | | | 8/8/1997 | | |
|
|
|
|
(F) Reprint permit | | | 8/8/1997 | | |
|
|
|
|
Telephone call | | | 7/8/1997 | | PASS |
|
|
|
SPOKE TO BLDR 8:00 AM.VLD
|
Inspection Record Card- Bld | | | 7/8/1997 | | PASS |
|
|
|
|
Plan assigned to (DJO) | 5/30/1997 | | 7/7/1997 | | PASS |
Dan Overy
|
|
|
07/07/97 15:53:01 DJO - this action updated by action script from <<>> in Case No. BLD97-1498
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/7/1997 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 7/7/1997 | | PASS |
|
|
|
information received.
|
Print Pending Permit.LaserJet4 | | | 7/7/1997 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 6/13/1997 | | PEND |
|
|
|
called designer and owner. additional information req. for header sizes, brg locations, sections, and overspan roof joists.
|
Plans ACCEPTED BY PLAN CHECK | | | 6/13/1997 | | PEND |
|
|
|
|
Routing - PLANNING | 6/3/1997 | | 6/12/1997 | | PASS |
|
|
|
Approved by: GRH
|
Routing - PUBLIC WORKS | 5/30/1997 | | 6/3/1997 | | PASS |
|
|
|
|
Application received | | | 5/30/1997 | | |
|
|
|
|
Routing - PLAN CHECK | 6/12/1997 | | | | PEND |
|
|
|
|