Permit Information
Permit NumberBLD97-02083
StatusFinaled
Name ANNIVERSARY INN
Site Address 1575 S LUSK ST
Project NameANNIVERSARY INN
Customer Number 
ePlanReviewNo
Description
ANNIVERSARY INN * TO CONSTRUCT A NEW 20,396 SQ FT., 41 UNIT MOTEL, 32 ROOMS WILL BE COMPLETED AT THIS TIME. CONSTRUCTION TO BE A TWO STORY, WITH A MEZZAINNES ON THE SECOND FLOOR AND A BASEMENT, WOOD FRAMED TYPE V-ONE-HOUR CONSTRUCTION, FULLY FIRE SPRINKLERED 13-R SYSTEM. THE INSTALLATION OF THE FIRE SPRINKLER SYSTEM IS PER SECTION 904.2.8 AND CAN NOT BE USED FOR ANY CODE REDUCTIONS. THE FIRST FLOOR IS APPROXIMATELY 9161 SQ.FT. THE SECOND FLOOR IS 10216 SQ.FT. WHICH INCLUDES THE MEZZANNINES, THE BASEMENT IS APPROXIMATELY 9720 SQ.FT. THIS PERMIT TO INCLUDE RELATED ON SITE WORK. MJP (PC#469-97) DR-97-97 CU-41-97
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final5/24/19995/25/19995/25/1999APASS
DetailsJim Storey
05/25/99 301 - Anniversary Inn, final reinspect
Permanent occupancy  5/25/1999 PASS
Perm. Occ. Cert. #7773 issued 5-25-99 to the Anniversary Inn.
Permanent Occupancy 5/24/19995/24/1999 DONE
Details
INSP - Final2/11/19992/11/19992/12/1999PPART
DetailsJim Storey
02/11/99 301 - pending p/z ok and bond release.
INSP-Final Inspection2/10/19992/11/19992/11/1999 PASS
DetailsJim Storey
02/11/99 301 - final ok on bldg. side pending p/z sign off.
INSP-Final Inspection2/10/19992/11/19992/11/1999APASS
DetailsRick Jackson
dennis ###-####- occ approved
INSP-Final Inspection2/4/19992/4/19992/4/1999P
DetailsMike Kinnear
Ron, ###-#### or Dennis (gen. mgr.)
SUPER- Supervisor's review2/3/19992/3/19992/3/1999
met with rick jackson sprinkler system still not completed per engineered design. 2 unfinished rooms still not allowed to be used for human occupancy
INSP-Final Inspection1/28/19991/28/19991/28/1999PPART
DetailsRick Jackson
RON ###-#### SPOKE WITH BILL ALEXANDER still need sidewall sprinkler for spare head box
SUPER- Supervisor's review1/20/19991/20/19991/20/1999
calculations for fire sprinkler system ok per bill alexander. work not completed as on site review showd. sprinkler pipe penitrating foam and is unprotected and some additional items per jim storeys c/n
Routing - FIRE1/14/1999 1/14/1999 PASS
Reviewed revised calculations for "No Access Hold" rooms (2 Palace Rooms, Lighthouse Room). Meet minimum requirements as designed per owner hired engineer, John Jensen PE.
INSP - Final1/13/19991/13/19991/13/1999 FAIL
DetailsJim Storey
/ / 301 - FIRE RE-SUBMITAL LACK OF INFO.ENGINEER TO VERRIFY AND RESUBM
Routing - FIRE1/12/1999 1/13/1999 FAIL
Plans and calculations did not match. Sent notice to John Jenson by secretary and another to Commercial Fire.
SUPER- Supervisor's review12/29/199812/29/199812/29/1998
sprinkler plan still lacks required design. Bill Alexander from our staff will concer with design engineer john jensen to remedy the problem.
Routing - FIRE12/29/1998 12/29/1998 FAIL
Review of resubmitted plan and calculations for Palace Rooms. Calculations and plans did not match. Could not follow. Called John Jenson at 208.529.5230, this date and informed him.
SUPER- Supervisor's review12/23/199812/23/199812/23/1998
2 rooms still unoccupied. state reviewing sprinkler plans ok
SUPER- Supervisor's review12/16/199812/16/199812/16/1998
john jensen fire protection engineer reworking system checked system redesign should be ok and is being submitted to state for approval.
Fee Review-notes12/8/1998 12/15/1998
SUPER- Supervisor's review12/14/199812/14/199812/14/1998
2 rooms to remain unoccupied they are specified on temp occ. resubmittals forthcomming and will be reviewed by the state. also by Bill Alexander here.
INSP - Final12/10/199812/10/199812/12/1998PPART
DetailsJim Storey
12/11/98 301 - signed off by george slane
SUPER- Supervisor's review12/11/199812/11/199812/11/1998
reviewd calks again not done per sprinkler plan. failior. compromise. all but 2 rooms meet, sprikler and alarms work in remainder. will allow temp on all but 2 rooms and they will be posted not to occupy. fireprotection engineer is reenvolved and realizes sprinkler contractor has failed to comply. mayers office supports this concept and will support us.
Temporary occupancy  12/11/1998 PASS
Temp. Occ. cert. #3754 issued 12-11-98 to the Anniversary Inn.
INSP-Final Inspection12/10/199812/10/199812/10/1998PFAIL
DetailsMike Kinnear
Fire sprinkler calculations and sprinkler piping installed did not match what was submitted as an asbuilt design for appoval. Instructed with notification to redesign, recalculate, resubmit.
SUPER- Supervisor's review12/11/199812/10/199812/10/1998
met with state of id. they will let us check calks. faile also plan was to be submitted to state month ago and was not floyd varley has details on fire case.
INSP - Final12/9/199812/9/199812/9/1998PPART
DetailsJim Storey
12/09/98 301 - roof draft stops and access ok corridor fire stopping ok
INSP-Final Inspection12/9/199812/9/199812/9/1998PFAIL
DetailsRick Jackson
requested by alarm company reinspect of alarms - okay. several sprinkler issues left. emergency lights okay.
SUPER- Supervisor's review12/9/199812/9/199812/9/1998
plans not submitted to state fire marshall for sprinkler or alarms. not approved for occupancy. they have been told for 2 weeks by our staff and their fire protection engineer to get state approval.
INSP - Final12/8/199812/9/199812/9/1998APART
DetailsJim Storey
roof draft stops ok fire stopping ok in corridors.
Routing - FIRE12/9/1998 12/9/1998 FAIL
Submittal of revised fire sprinkler upgrade plans and calculations from NFPA #13D to NFPA #13 reviewed. Revised plans and calculations did not coincide with what was installed in Palace Room 1st floor and Palace Room 2nd Floor.
INSP-Sprinkler Rough-in/Hydro12/8/199812/8/199812/8/1998PPART
DetailsRick Jackson
checked heads to meet John Jensen's changes - okay
INSP - Wall cover12/8/199812/8/199812/8/1998PPASS
DetailsJim Storey
12/08/98 301 - SCLG-OK SUSPENDED CEILING
INSP - Framing/Rough-in12/7/199812/7/199812/8/1998PPART
DetailsRuss Owen
12/08/98 407 - ok to drop lids in hallway.
INSP-Alarm Testing12/7/199812/7/199812/7/1998AFAIL
DetailsRick Jackson
all detectors not installed per plans; doors with hold opens not complete; two smokes and 1 strobe not working; NFPA 72 and plans; install detector in future guest room and room 32 - c/n issued
INSP-Sprinkler Rough-in/Hydro12/7/199812/7/199812/7/1998APASS
DetailsRick Jackson
hydro only - pass
Code Occupancy Approval  12/7/1998
Final Requested by Mike Cullens--###-####
INSP-Final Inspection12/2/199812/4/199812/4/1998AFAIL
DetailsRick Jackson
###-#### RALPH alarms not complete; address; fire marshall plans; test alarms; door holders/closures not on; etc, etc
INSP-Conference12/3/199812/3/199812/3/1998PFAIL
DetailsRick Jackson
alarms not complete; state approved sprinkler plans,
INSP - Framing/Rough-in12/3/199812/3/199812/3/1998P
DetailsJim Storey
mike ###-#### per jim storey for 12-03-98 pm
SUPER- Supervisor's review12/1/199812/1/199812/1/1998
revied approval request from John Jensen P.E. he is using sprinkler system as alternate to removing foam. We will accept this for the foam but the foam covered with the bed liner material has to be covered or removed. State has to review sprinkler and alarm plan befor we can procee. We cannot occupy until all approvals and inspections have taken place.
SUPER- Supervisor's review11/24/199811/24/199811/24/1998
engineers letter and submittal on aniversery inn lacks required information. flows calcs and tests on rino covering for flame spread smoke dev. and is rejected. Sprinkler design will have to be approved by the state.
SUPER- Supervisor's review11/23/199811/23/199811/23/1998
reviewd progress on foam platic acceptance. still no approved tests. foam platic application still not approved.
INSP - Wall cover11/18/199811/19/199811/19/1998AFAIL
DetailsJim Storey
11/19/98 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP-Conference11/13/199811/13/199811/13/1998PPART
DetailsRick Jackson
jensen,pe is to come up with plan to increase sprinkler density within rooms having foam
SUPER- Supervisor's review11/13/199811/13/199811/13/1998
on site review with fire protection engineer John Jensen P.E. ###-####. reviewed each room. He will design specific sprinkler system for each non complying room. also will submit covering of foam for finish rating. He is stamping and providing engineered alternate to the code. we will await his submittat.
SUPER- Supervisor's review11/12/199811/12/199811/12/1998
fireprotection engineer involved. John Jensen. He is proposing to cover foam with class 3 material and sprinkle with quick response heads. Our position is for an engineered evaluation, which is stamped detailing the compliance alternate and we would allow no less than class one material over the platic.
SUPER- Supervisor's review11/3/199811/2/199811/2/1998
Received resumittals for covering of foam platic. 1. Themalastic 83c 2. Tuff Stuff FR from Rhino Linings. 3. Hydrothane 60D-Class 1 from Hydroseal Polymers Inc. will evaluate and provide ruling. Again purpose of the coatings are to provide a thermal barrier of 15 and encapsulate the foam. It needs to provide engineering judgment providing flame spread, smoke development. How foam will stay in place in the event of fire. The engineering judgement need to refer to each application for specific rooms and be specific to that application.
SUPER- Supervisor's review11/2/199810/30/199810/30/1998
new products to cover foam sumitted floyd varley has submitals for alternate methods. will review for approval monday 11-2-98
SUPER- Supervisor's review10/23/199810/22/199810/22/1998
met with architect, contractor and fire inspectors, and floyd varley. they are attempting to get a covering that meets index of 15 per ubc chapter 26 for interior finish. I informed them that we all had a sense of urgancy to find a product or remove the foam. No occupancy can be allowed until this issue meets the code.
INSP-Conference10/22/199810/22/199810/22/1998APART
DetailsRick Jackson
conference with George and architect about interior use of foam and spray on finishes. arc. to supply more data for approval
SUPER- Supervisor's review10/20/199810/20/199810/20/1998
foam platic review with Ron Lynn asstant building official in Clark County Nevada. Ron stated that he agreed with our call that it would not meet trim requirements. If we treat it as finish it should be tested per chapter 26. for finish and covered with appropriate finish material to allow it at all. I explained that we felt full coverage sprinkling was also necessary and it agreed. Ron stated that their fire protection engineer was the top expert in the nation on the subject and he would leave word with him to give us full cooperation. Doug Evans is the engineer ph-###-####.
INSP-Conference10/19/199810/19/199810/19/1998PPART
DetailsRick Jackson
issued and reviewed c/n with contractor about sprinkler problems
SUPER- Supervisor's review10/15/199810/15/199810/15/1998
inspector field trip. reviewed possible problem with installation of non compliant foam plastic as it relates to chapter 26 foam platic general. chapter 6 trim. chapter 8 interior finish.
INSP-Sprinkler Rough-in/Hydro10/15/199810/15/199810/15/1998PFAIL
DetailsRick Jackson
continued sprinkler rough-in, c/n forthcoming
INSP-Sprinkler Rough-in/Hydro10/14/199810/14/199810/14/1998AFAIL
DetailsRick Jackson
c/n to be issued for numerous sprinkler problems
SUPER- Supervisor's review10/13/199810/13/199810/13/1998
foam platic used as trim on various units. exceeds code for trim. exploring alternate methods. 1. one hour paint? 2. deluge sprinklers?
INSP-Sprinkler Rough-in/Hydro10/13/199810/13/199810/13/1998PFAIL
DetailsRick Jackson
bathroom corridor not sprinklered; linen/mop closet not sprinklered; overspacing with sidewalls
SUPER- Supervisor's review10/2/1998 10/1/1998 305
finish material in question ul sending info
INSP - Framing/Rough-in9/28/19989/29/19989/29/1998PPASS
DetailsJim Storey
09/29/98 301 - mike ###-#### GWB -OK SHEETROCK NAILING ì
INSP - Wall cover9/28/19989/28/19989/28/1998 PASS
DetailsJim Storey
/ / 301 - GEN -GENERAL INSPECTION fire stopping and gaurd raillings stair height o
INSP - Energy code compliance9/21/19989/22/19989/22/1998ACANC
DetailsRuss Owen
09/22/98 407 - trans to 301.
INSP - Wall cover8/19/19988/19/19988/19/1998 PASS
DetailsJim Storey
/ / 301 - reviewed w/arch fire damper access and drop ceillings in wat pending submitals. approved rated shaft assembly for bolier flue. need submital for change of round flue to oval for mech review to meet cleara of flue in shaft.
INSP - Energy code compliance8/13/19988/14/19988/14/1998APASS
DetailsJim Storey
08/14/98 301 - MIKE ###-#### INSL-OK INSULATION ì
INSP - Framing/Rough-in8/13/19988/14/19988/14/1998APASS
DetailsJim Storey
08/14/98 301 - WALL COVER MIKE ###-#### GWB -OK SHEETROCK NAILING
INSP - Framing/Rough-in8/5/19988/6/19988/6/1998PPASS
DetailsJim Storey
08/06/98 301 - FRAMING 3RD STORY MIKE ###-#### FRAM-OK FRAMING
INSP - Framing/Rough-in7/24/19987/27/19987/27/1998AFAIL
DetailsJim Storey
07/27/98 301 - Scheduled by Hello!. Contact phone is [8901616]. CORR-CORREC-CALL FOR REINSP WHEN COMPLETED ok to insulate exterior walls floor .
INSP - Energy code compliance7/21/19987/22/19987/22/1998PPART
DetailsJim Storey
07/22/98 301 - Scheduled by Hello!. Contact phone is [3319055]. FRAM-OK FRAMING ok and insulation ok for 2nd floor .
INSP - Energy code compliance7/17/19987/20/19987/20/1998APASS
DetailsJim Storey
07/20/98 301 - Scheduled by Hello!. INSL-OK INSULATION
INSP - Energy code compliance7/17/19987/17/19987/17/1998 PART
DetailsJim Storey
07/16/98 301 - ###-#### bill CORR-CORREC-CALL FOR REINSP WHEN COMPLETED ok to start lids ì
INSP - Wall cover7/6/19987/7/19987/7/1998APART
DetailsJim Storey
07/07/98 301 - 2nd floor ok for insulation/ first floor ok to hang ceill lacking r/c chanel reinsp required.
INSP - Framing/Rough-in7/1/19987/2/19987/2/1998APART
Details
07/02/98 333 - basement ok to insulate
INSP - Energy code compliance6/16/19986/17/19986/18/1998AFAIL
DetailsJim Storey
06/17/98 301 - n/r conf only.
SUPER- Supervisor's review6/18/1998 6/17/1998
profit team meeting for temp occ. inspectors at meeting and formulated list for completion. only problem. e-mail not working properly and joe did not get meeting notice. problem with perrys computer?
INSP-Sprinkler Rough-in/Hydro6/15/19986/15/19986/15/1998PPART
DetailsRick Jackson
riser and all areas not complete. not approved for cover.
INSP - Framing/Rough-in5/12/19985/12/19985/12/1998PPART
DetailsJim Storey
05/12/98 301 - SHRW-OK SHEARWALL NAILING on all but wall framing north f
INSP-Conference4/9/19984/9/19984/9/1998APART
DetailsRick Jackson
pre-con with Jim S. and contractor/subs. requested alarm submittals - contract for alarms not let as of today
INSP - Framing/Rough-in4/3/19984/3/19984/3/1998APART
DetailsJim Storey
conf. set up preconst meeting for 4/9/98
INSP-Supply line flush3/30/19983/30/19983/30/1998APASS
DetailsRick Jackson
underground hydro and flush okay
INSP - Foundation3/23/19983/23/19983/23/1998PPASS
DetailsJim Storey
03/23/98 301 - Scheduled by Hello!. wall ok
INSP - Foundation3/19/19983/19/19983/20/1998PPASS
DetailsJim Storey
03/20/98 301 - FRMS-OK FORMS-REBAR
INSP - Foundation3/17/19983/18/19983/18/1998PPASS
DetailsJim Storey
Scheduled by Hello!. Contact phone is [8901616]. slab and thickened footings ok
INSP - Foundation3/9/19983/9/19983/9/1998PPASS
DetailsJim Storey
03/09/98 301 - Scheduled by Hello!. Contact phone is [8901616]. FDN -OK FOUNDATION
INSP - Foundation3/5/19983/5/19983/5/1998PPASS
DetailsJim Storey
03/05/98 301 - bill ###-#### FRMS-OK FORMS-REBAR EAST AND NORTH WALL LINES ì
INSP - Foundation2/26/19982/27/19982/27/1998PPASS
DetailsJim Storey
02/27/98 301 - FOR STEEL--MIKE ###-####--ANNIVERSARY INN FRMS-OK FORMS-REBAR
INSP - Foundation2/23/19982/23/19982/23/1998PPASS
DetailsJim Storey
02/23/98 301 - ###-#### MIKE FRMS-OK FORMS-REBAR ì
(F) Reprint permit  2/4/1998
(F) Reprint permit  2/4/1998
Issue PAID IN FULL permit  2/3/1998
Inspection Record Card- Bld  2/3/1998
Telephone call  2/3/1998
left message for mike greer on voice mail
Print Occupancy Form  2/3/1998
Print Pending Permit.LaserJet4  2/2/1998 PASS
PLANS/APPL TAKEN TO FRONT DESK  2/2/1998 PASS
Plan Reviewer's activity  2/2/1998 PASS
Plan assigned to (M_P)10/14/1997 2/2/1998 PASS
DetailsMike Phillips
02/02/98 15:22:25 DAR - this action updated by action script from <<>> in Case No. BLD97-2083
Routing - PUBLIC WORKS1/28/1998 1/29/1998 PASS
Routing Off Site - C.D.H1/12/1998 1/14/1998 PASS
TALKED TO ROB MAYER, ASKED IF ANNIVERSARY INN HAS CONTACTED THEM FOR A PLAN REVIEW. HIS COMMENT IS THAT HE HAS HEARD OR SEEN THE PLANS AS OF TODAY.
Plan Reviewer's activity  1/12/1998 HOLD
CENTRAL DISTRICT HEALTH HASS NOT RECEIVED APPLICATION FROM ARCHITECT OR OWNER AS OF YET.
Plan Reviewer's activity  1/8/1998
received complete package of resubmittals, submittal included 41 pages out of 48 sheets in the original submittal./
Routing Off Site - STRUCTURAL12/23/1997 1/7/1998 PASS
SENDING RESUBS TO ATWOOD HINZMAN JONES.` no further review required.
Routing - PUBLIC WORKS12/23/1997 12/29/1997 FAIL
NO CHANGE.
Routing - PUBLIC WORKS12/5/1997 12/8/1997 FAIL
Routing - FIRE12/1/1997 12/4/1997 PASS
Print Pending Permit.LaserJet4  12/1/1997 FAIL
Plan resubmittals requested  12/1/1997 FAIL
Plan Reviewer's activity  12/1/1997 FAIL
SENT CORRECTION NOTICE.
Routing Off Site - STRUCTURAL10/28/1997 11/9/1997 FAIL
CONTACTED PDQ TO TAKE PLANS OUT TO ATWOOD HINZMAN AND JONES SENDING CORRECTION NOTICE FROM OUTSIDE STRUCTURAL FIRM WITH MY REPORT.
Additional plans submitted  10/28/1997 PASS
AN ADDITIONAL SET OF ONE SUBMITTAL RECEIVED TO GO OUT TO ATWOOD HINZMAN AND JONES ALONG WITH A SOILS REPORT AND CALCS.
90 day tracking............. 7/21/199710/19/1997
Plan assigned to (RGG)7/23/1997 10/14/1997 PASS
Routing - PUBLIC WORKS10/9/1997 10/13/1997 FAIL
REQUIRES DRAINAGE PLAN REVISIONS PER BRIAN MURPHY AND C.S.
Routing - ELECTRICAL9/25/1997 9/25/1997 PASS
FIELD VERIFY.
Routing - PLUMBING9/15/1997 9/24/1997 PASS
Routing - PUBLIC WORKS9/3/1997 9/15/1997 FAIL
REQUIRES DRAINAGE PLAN REVISION.
Routing - PLANNING8/28/1997 8/29/1997 PASS
Approved by: TKW & RAC
Routing Off Site - A.C.H.D7/25/1997 8/26/1997 PASS
CONTACTED ALLEN QUINTIERI AT ###-#### TO TAKE PLANS OUT TO ACHD ACHD FEE PAID 1/16/98
Plans ACCEPTED BY PLAN CHECK  7/25/1997 PASS
RECEIVED DARINAGE CALCS AND SOILS REPORT, READY TO ROUTE.
Plan routing begun/NEW & ADDTN  7/25/1997 PASS
Routing - MECHANICAL7/25/1997 7/25/1997 PASS
NO REVIEW FIELD VERIFY.
Plans ACCEPTED BY PLAN CHECK  7/23/1997 HOLD
CONTACTED ALLEN QUINTIERI TO LET HIM KNOW THAT I NEED DRAINAGE CALCS. AND A SOIL REPORT DONE BY GEO-TECH. 7-25-97 RECEIVED DRAINAGE CALCS. AND SOILS REPORT. READY TO ROUTE
Received Certificate of Value  7/23/1997 PASS
Plan routing begun/NEW & ADDTN  7/23/1997 HOLD
SEE ACTION 007 HOLD
Plan assigned to (MYS)7/21/1997 7/23/1997
DetailsMarlene Southard
Recd Pcfee & Taken To Pln CK  7/21/1997
Application received  7/18/1997