Case Summary (BLD) | | | 6/13/2005 | | |
|
|
|
|
INSP - Final | 9/9/1998 | 9/10/1998 | 9/10/1998 | A | PASS |
Wes Worcester
|
|
|
09/10/98 342 - Scheduled by Hello!. Contact phone is [8904531].
|
INSP - Grading Inspection | 9/8/1998 | 9/9/1998 | 9/8/1998 | | PASS |
Rita DeYoung
|
|
|
Final grading and drainage has been completed according to the approved plan and is approved by Public Works
|
INSP - Final | 8/24/1998 | 8/25/1998 | 8/25/1998 | P | NR |
Wes Worcester
|
|
|
08/24/98 342 - Scheduled by Hello!. Contact phone is [8904531].
|
INSP - Energy code compliance | 3/5/1998 | 3/5/1998 | 3/5/1998 | | PASS |
Wes Worcester
|
|
|
/ / 342 -
|
INSP - Framing/Rough-in | 3/4/1998 | 3/5/1998 | 3/5/1998 | A | PASS |
Wes Worcester
|
|
|
03/05/98 342 - Scheduled by Hello!. Contact phone is [8904531].
|
INSP - Framing/Rough-in | 3/3/1998 | 3/4/1998 | 3/4/1998 | A | PART |
Wes Worcester
|
|
|
03/03/98 342 - Scheduled by Hello!. Contact phone is [8904531].
|
INSP - Energy code compliance | 3/4/1998 | 3/4/1998 | 3/4/1998 | | NR |
Wes Worcester
|
|
|
/ / 342 -
|
INSP - Energy code compliance | 3/4/1998 | 3/4/1998 | 3/4/1998 | | NR |
Wes Worcester
|
|
|
/ / 342 -
|
INSP - Framing/Rough-in | 2/27/1998 | 2/27/1998 | 2/27/1998 | P | FAIL |
Wes Worcester
|
|
|
02/27/98 342 - need plan and engineering on site
|
INSP - Framing/Rough-in | 10/22/1997 | 10/23/1997 | 10/23/1997 | A | NH |
Wes Worcester
|
|
|
10/22/97 342 - no one there ... no frame standing????
|
INSP - Foundation | 10/10/1997 | 10/10/1997 | 10/10/1997 | P | PASS |
Wes Worcester
|
|
|
CONCRETE WALL
|
INSP - Footings | 10/6/1997 | 10/6/1997 | 10/6/1997 | P | PART |
Wes Worcester
|
|
|
PLAN SHOWS A KEYWAY IN GARAGE FTG....ASKED BLDR TO RESPOND AS IT IS NOT INSTALLED.
|
INSP - Footings | 10/3/1997 | 10/6/1997 | 10/2/1997 | A | CANC |
Wes Worcester
|
|
|
CHANGED TO PM
|
INSP - Footings | 10/1/1997 | 10/1/1997 | 10/1/1997 | P | NR |
Wes Worcester
|
|
|
no rebar in hole, no one on site, no plan on site
|
Issue PAID IN FULL permit | | | 8/26/1997 | | |
|
|
|
|
Inspection Record Card- Bld | | | 8/25/1997 | | |
|
|
|
|
Telephone call | | | 8/25/1997 | | |
|
|
|
PERMIT READY, TALKED TO EARL
|
Plan assigned to (PRP) | 7/30/1997 | | 8/23/1997 | | PASS |
|
|
|
08/23/97 11:05:56 PRP - this action updated by action script from <<>> in Case No. BLD97-2212
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/23/1997 | | PASS |
|
|
|
ISSUE
|
Print Pending Permit.LaserJet4 | | | 8/23/1997 | | PASS |
|
|
|
FILES
|
Routing - PLAN CHECK | 8/22/1997 | | 8/23/1997 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 8/23/1997 | | PASS |
|
|
|
REVIEWED PLANS, MARK-UP, INPUT TO TIDEMARK, ASSEMBLE, ISSUE
|
Routing - PLANNING | 8/20/1997 | | 8/21/1997 | | PASS |
|
|
|
APPROVED BY GRH.
|
Routing - PUBLIC WORKS GRADING | 8/19/1997 | | 8/19/1997 | | PASS |
Rita DeYoung
|
|
|
Approved as Category 3
|
Application received | | | 7/30/1997 | | |
|
|
|
|
Routing - PUBLIC WORKS | 7/30/1997 | | 8/20/1987 | | PASS |
|
|
|
|