Letter of compliance | | | 2/1/1999 | | PASS |
|
|
|
Letter of Compliance #14966 issued 2-1-99 to Hasegawa & Associates.
|
INSP - Final | 1/29/1999 | 1/29/1999 | 1/29/1999 | P | PASS |
|
|
|
dean- ###-#### fn insp- madeok to sign oc req card with 406 signoff
|
INSP-Final Inspection | 1/28/1999 | 1/28/1999 | 1/28/1999 | P | PASS |
Joe Tawney
|
|
|
01/28/99 406 - BILL ###-#### REINSP OK FOR CERT OF COMPLETION ì
|
Print Occupancy Form | | | 11/18/1998 | | |
|
|
|
|
INSP-Alarm Testing | 10/30/1998 | 10/30/1998 | 10/30/1998 | P | PASS |
|
|
|
trip test and detectors passed, need spare heads
|
INSP - Final | 8/31/1998 | 8/31/1998 | 8/31/1998 | | PART |
|
|
|
/ / 338 - MADEOK FOR TEMP TEMP CONTITIONS IN FORCE
|
INSP-Final Inspection | 8/28/1998 | 8/29/1998 | 8/29/1998 | | PART |
|
|
|
dry system converted to wet, dampers locked closed until alarms complete
|
INSP-Final Inspection | 8/27/1998 | 8/28/1998 | 8/28/1998 | A | FAIL |
|
|
|
dry sprinkler system failed trip time test, smoke dampers would not close, not connected to alarms
|
INSP - Final | 8/27/1998 | 8/28/1998 | 8/28/1998 | A | FAIL |
|
|
|
not ready for insp alarms and sprink system are caputs
|
INSP - Final | 8/28/1998 | 8/28/1998 | 8/28/1998 | | FAIL |
|
|
|
08/28/98 338 - sprink system and alarms and dampers does not work
|
INSP - Final | 8/27/1998 | 8/27/1998 | 8/27/1998 | | NR |
Joe Tawney
|
|
|
/ / 406 - FINAL NOT READY
|
INSP - Final | 8/27/1998 | 8/27/1998 | 8/27/1998 | | NR |
Joe Tawney
|
|
|
/ / 406 - FINAL NOT READY
|
INSP-Sprinkler Rough-in/Hydro | 8/24/1998 | 8/24/1998 | 8/24/1998 | | PART |
Joe Tawney
|
|
|
/ / 406 - OK ON ABOVE GROUND HYDRO TEST EXC FDC & SUPPLY LINE TO BE TE UNDERGROUND OK ON CORRIDOR & CLASSROOM ROUGH IN WITH NOTED CORRECTIONS
|
INSP-Conference | 8/14/1998 | 8/14/1998 | 8/14/1998 | | PART |
Joe Tawney
|
|
|
/ / 406 - CONF ON WHAT REQ FOR OCC DID NOT HAVE FD REVIEW W/PLANS PROV
|
INSP - Framing/Rough-in | 5/26/1998 | 5/26/1998 | 5/26/1998 | P | PART |
|
|
|
###-#### to wet to get on the roof
|
INSP - Framing/Rough-in | 4/24/1998 | 4/27/1998 | 4/27/1998 | A | PART |
|
|
|
04/27/98 338 - SP INSP APROVAL MADE OK MISC COL AT PER.
|
INSP - Foundation | 4/21/1998 | 4/22/1998 | 4/22/1998 | P | PART |
|
|
|
04/22/98 338 - COLUMN POUR TEST SP INSP MADE OK
|
INSP - Foundation | 4/16/1998 | 4/17/1998 | 4/17/1998 | A | PART |
|
|
|
04/17/98 338 - poured with sp insp onlyScheduled by Hello!.
|
Voucher Form | | | 4/6/1998 | | |
|
|
|
1436.80 WAS COLLECTED FOR PLAN CHECK 12/09/97-4222.00 WAS PAID FOR PLANCHECK AND IT WAS TO MUCH. LH
|
INSP - Foundation | 4/2/1998 | 4/3/1998 | 4/3/1998 | A | PART |
|
|
|
04/03/98 338 - no answer on the phone forman not on site
|
(F) Reprint permit | | | 3/30/1998 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 3/20/1998 | | |
|
|
|
|
90 day tracking............. | | 12/9/1997 | 3/9/1998 | | PEND |
|
|
|
|
Telephone call | | | 2/20/1998 | | |
|
|
|
CALLED DAVID BLENKER/THEY JUST AWARDED CONTRACT. CONTRACTOR SHOULD BE IN VERY SOON TO PICK UP
|
PLANS/APPL TAKEN TO FRONT DESK | | | 1/27/1998 | | PASS |
|
|
|
|
Print Occupancy Form | | | 1/27/1998 | | |
|
|
|
|
Inspection Record Card- Bld | | | 1/27/1998 | | |
|
|
|
|
Routing - PLAN CHECK | 1/21/1998 | | 1/26/1998 | | PASS |
|
|
|
|
Plan assigned to (M_O) | 12/9/1997 | | 1/26/1998 | | PASS |
|
|
|
|
Plan resubmittals received | | | 1/21/1998 | | PEND |
|
|
|
RECEIVED RESUBS FROM ARMSTRONG ARCHITECTS. (DAVID BLENKER)
|
Routing - FIRE | 12/19/1997 | | 12/31/1997 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 12/15/1997 | | 12/18/1997 | | FAIL |
|
|
|
corrections mailed and faxed to architect. mo
|
Routing - PLANNING | 12/12/1997 | | 12/15/1997 | | PASS |
|
|
|
APPROVED BY SRS.
|
Routing - PLUMBING | 12/11/1997 | | 12/12/1997 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 12/9/1997 | | 12/11/1997 | | PASS |
|
|
|
|
Plan assigned to (MYS) | 12/9/1997 | | 12/9/1997 | | |
Marlene Southard
|
|
|
|
Routing - ELECTRICAL | 12/9/1997 | | 12/9/1997 | | PASS |
|
|
|
NO REVIEW WILL FIELD VERIFY.
|
Plan routing begun/NEW & ADDTN | | | 12/9/1997 | | PASS |
|
|
|
|
Received Certificate of Value | | | 12/9/1997 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 12/9/1997 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 12/9/1997 | | PEND |
|
|
|
|
Application received | | | 12/9/1997 | | |
|
|
|
|