Information based on query as of Sunday, August 18, 2024.
Permit Information
Permit NumberBLD98-01236
StatusFinaled
Name JACOBS MIKE P AND
Site Address 5240 S DESELM WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 1854 sq. ft. split-level single family dwelling with a 507 sq. ft. attached two car garage and concrete patio per approved plans, all attached engineering and requirement lists. This structure will meet hillside requirements. Special inspection is required per ICBO report #ER-4203 (RASTRA PANEL SYSTEM). Reference condition list for Special Inspection features. (lower level 362 sq. ft.) (main level 567 sq. ft.) (upper level 925 sq. ft.) DJO ACHD #98-1434 PC #470
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final2/18/19992/19/19992/19/1999APASS
DetailsRuss Owen
02/19/99 407 - special inspection ok,
INSP - Final2/18/19992/18/19992/18/1999PFAIL
DetailsRuss Owen
02/18/99 407 - left correction.
INSP - Grading Inspection2/17/1999 2/17/1999 BOND
DetailsRita DeYoung
Rough grading is complete. Fine grading, revegetation, a retaining wall and the driveway are not complete. For these items the engineer has recommended a surety of $1615.00. This is acceptable and upon receipt of this surety the grading is conditionally approved.
INSP - Energy code compliance12/7/199812/8/199812/8/1998APASS
DetailsRuss Owen
12/08/98 407 - ROB ###-####
INSP - Framing/Rough-in12/4/199812/7/199812/7/1998APART
DetailsRuss Owen
12/07/98 407 - HAS WINDOW EGRESS OUT OF LOWER BEDROOM TO SMALL,CONTRACTO
INSP - Foundation7/16/19987/17/19987/17/1998APART
DetailsRuss Owen
SUBJECT TO SPECIAL INSP.32
INSP - Foundation7/10/19987/13/19987/13/1998PFAIL
DetailsRuss Owen
07/13/98 407 - this requiers an engineer approval for hill side,also special inspection as per the NER report,before all poures as this is not conventional construction also see notes from plan checker,house also does not meet front setbacks.footing/ mike jacobs/
(F) Reprint permit  6/26/1998
Print Pending Permit.LaserJet4  6/26/1998 PASS
Issue PAID IN FULL permit  6/26/1998
Inspection Record Card- Bld  6/26/1998
Print Occupancy Form  6/26/1998
Telephone call  6/26/1998 MESS
left message on machine ###-####
Plan Reviewer's activity  6/26/1998 PASS
received roof frame diagram
PLANS/APPL TAKEN TO FRONT DESK  6/26/1998 PASS
Plan assigned to (DJO)5/4/1998 6/26/1998 PASS
DetailsDan Overy
06/26/98 09:09:52 DJO - this action updated by action script from <<>> in Case No. BLD98-1236
Plans ACCEPTED BY PLAN CHECK  6/25/1998 PEND
Plan Reviewer's activity  6/25/1998 PEND
NEED ROOF FRAMING.
Routing - PLANNING6/15/1998 6/16/1998 PASS
Routing - PUBLIC WORKS5/4/1998 6/15/1998 PASS
Routing - PUBLIC WORKS GRADING6/12/1998 6/12/1998 PASS
DetailsRita DeYoung
Received revised plan that shows rear yard setback. Approved as category 3.
Routing - PUBLIC WORKS GRADING5/14/1998 5/13/1998 FAIL
DetailsRita DeYoung
Grading plan doesn't indicate any setback from descending slope at rear of house. Contacted engineer and contractor and asked for revised grading plan.
Application received  5/4/1998
Routing - PLAN CHECK6/16/1998   PEND