INSP - Final | 4/23/1999 | 4/23/1999 | 4/23/1999 | P | PART |
|
|
|
04/23/99 338 - made ok for temp occ signed the temp occ card need perm o
|
INSP - Final | 4/21/1999 | 4/22/1999 | 4/22/1999 | P | FAIL |
|
|
|
c/n iiisued signage and signoffs
|
INSP-Final Inspection | 4/22/1999 | 4/22/1999 | 4/22/1999 | P | FAIL |
Rick Jackson
|
|
|
occ load signs; extinguishers; sprinkler head in cooler; assembly permit required
|
INSP-Alarm Testing | 4/21/1999 | 4/21/1999 | 4/21/1999 | P | FAIL |
Rick Jackson
|
|
|
tested duct detectors only - didn't shut down heat pumps
|
Print Occupancy Form | | | 4/20/1999 | | |
|
|
|
|
Print Occupancy Form | | | 4/20/1999 | | |
|
|
|
|
Fee Review-notes | 12/23/1998 | | 3/28/1999 | | |
|
|
|
|
INSP-Conference | 3/9/1999 | | 3/9/1999 | | PART |
|
|
|
RESUBMITTALS DISCUSSED WITH CJW AND KYLE OF BRS OK TO CONSTRUCT DUMMY SHAFT BY WRIGHT LEISURE BUT NEEDS PROPER ASSY FOR SAME SHAFT. DUCT CAN BE PLACED BUT WILL BE CAPPED AT THE TOP AND THE BOTTOM. ACCESS TO THE CLEANOUT AT THE TRANSITION ABOVE THE 2ND FLOOR LEVEL IS REQUIRED. SEPERATE PERMITS ARE REQUIRED FOR THE FUTURE HOOD AND SHAFT TO BE DONE AT A LATER DATE. 2-HRS
|
Plan resubmittals received | | | 3/9/1999 | | |
|
|
|
RECEIVED TWO COPIES OF STAMPED AND SIGNED REVISED SHEETS A-1, A-1.1, A-2. ROUTED TO PERRY PAINE. KMM
|
Plan resubmittals received | | | 2/23/1999 | | |
|
|
|
THE RESUBS. I RECEIVED 2-18-99 ARE BACK WITH CLOUDING. ROUTED TO PERRY P. KMM
|
INSP - Framing/Rough-in | 2/18/1999 | 2/19/1999 | 2/19/1999 | A | PART |
Jim Storey
|
|
|
02/19/99 301 - grid line 9 &12 ok for cover. pennatrations ok on grid li
|
Plan resubmittals received | | | 2/18/1999 | | |
|
|
|
RECEIVED TWO COPIES OF STAMPED AND SIGNED PLANS WITH ONE COPY OF R2H ENGINEERING, INC. LETTER. ROUTED TO PERRY. KMM
|
Plan resubmittals received | | | 2/10/1999 | | FAIL |
|
|
|
RECEIVED ONE COPY OF REVISED PLANS HOWEVER THEY WERE NOT STAMPED OR SIGNED. CONTACTED KYLE OF THIS NEED. KMM
|
INSP - Framing/Rough-in | 2/4/1999 | 2/5/1999 | 2/5/1999 | A | PART |
|
|
|
02/05/99 338 - made ok to cover the screen wall only cept for the penetr
|
INSP - Foundation | 1/20/1999 | 1/22/1999 | 1/22/1999 | A | PART |
|
|
|
made ok to pour with sp insp approval
|
Issue PAID IN FULL permit | | | 12/28/1998 | | |
|
|
|
|
Plan Reviewer's activity | | | 12/18/1998 | | |
|
|
|
New kitchen equipment drawings were incorporated into the approved drawing. According to the architect, the 3-compartment fryer, under counter dishwasher, and above counter pizza oven were deleted. There were no proposed changes to the architectural, structural, electrical, plumbing, or mechanical drawings. Drawings sent to Central District Health Department for review.
|
Plan resubmittals received | | | 12/18/1998 | | PEND |
|
|
|
RECEIVED RESUBMITTALS FROM BRS, FORWARDED SAME TO CARL WESTFALL. DAR 12/18/98
|
Office Staff conference/action | | | 12/15/1998 | | |
|
|
|
LOUISE HAS PLANS/SHE WILL GIVE THEM BACK TO CARL/MPS
|
Office Staff conference/action | | | 12/14/1998 | | PEND |
|
|
|
gave plans back to plan check dave radford/mps CARL HAD PLANS
|
Ready Permit EXTENDED | | | 12/9/1998 | | EXTD |
|
|
|
as per dave hattrick okay to extend for 6 months / one time only
|
Telephone call | | | 12/8/1998 | | PEND |
|
|
|
called talked to arch. he will have general call me to let me know when he is going to come and pick up permit.
|
Print permit w/o conditions | | | 11/30/1998 | | |
|
|
|
|
testing condition printout | | | 11/30/1998 | | |
|
|
|
|
Plan Reviewer's activity | | | 11/30/1998 | | PASS |
|
|
|
Drawings approved November 30, 1998 after resubmittal review and approved by the Director to allow a wheelchair lift in lieu of an elevator.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/30/1998 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 7/20/1998 | | 11/30/1998 | | PASS |
|
|
|
|
Plan assigned to (CJW) | 6/5/1998 | | 11/30/1998 | | PASS |
Carl Westfall
|
|
|
11/30/98 15:52:00 CJW - this action updated by action script from <<>> in Case No. BLD98-1537
|
Plan resubmittals received | | | 8/10/1998 | | |
|
|
|
RECEIVED TWO COPIES OF REVISED SHEETS A-1, A-1.1, A-2, AND ONE COPY OF ELEVATOR BID AND MEMO. ROUTED TO CARL W.
|
Routing - PLANNING | 7/16/1998 | | 7/17/1998 | | PASS |
|
|
|
|
Plan Review Completed(1st rev) | | | 7/16/1998 | | FAIL |
|
|
|
ubc issues
|
Routing - FIRE | 6/24/1998 | | 7/16/1998 | | PASS |
|
|
|
field check emergency lights, special address requirements, tie hood to FA system
|
Routing - PLANNING | 6/24/1998 | | 6/24/1998 | | PASS |
|
|
|
drh98-0161 - this approval is only for exterior alley elevation for Mugs and Movie portion of building (the center portion of the alley elevation).
|
Plan Reviewer's activity | | | 6/17/1998 | | |
|
|
|
UBC plan review started June 17, 1998 and finished June 22, 1998. A response from the architect is required. See the conditions list for items requiring a response.
|
Routing - PLAN CHECK | 6/16/1998 | | 6/17/1998 | | |
|
|
|
|
Routing - PLUMBING | 6/15/1998 | | 6/16/1998 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 6/9/1998 | | 6/15/1998 | | PASS |
|
|
|
|
Routing Off Site - C.D.H | 6/5/1998 | | 6/9/1998 | | PASS |
|
|
|
|
Plan routing begun/TENANTS | | | 6/5/1998 | | |
|
|
|
Route to CENTRAL DISTRICT HEALTH, PUBLIC WORKS, PLUMBING, PLANNING, PLAN CHECK and FIRE.
|
Plan assigned to (MYS) | 6/1/1998 | | 6/5/1998 | | |
Marlene Southard
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 6/3/1998 | | PEND |
|
|
|
CONTACTED KYLE FREUTEL TO LET HIM KNOW THAT WE NEED A SOILS REPORT. THEY ARE USING A PSF OF 2,500
|
Recd Pcfee & Taken To Pln CK | | | 6/1/1998 | | PEND |
|
|
|
|
Application received | | | 6/1/1998 | | |
|
|
|
|
Received Certificate of Value | | | 6/1/1998 | | PASS |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|
Plan Review Report | | | | | |
|
|
|
|
Routing - PLUMBING | 2/25/1999 | | | | PASS |
|
|
|
RESUBMITTALS APPROVED BY PUBLIC WORKS.
|