Permit Information
Permit NumberBLD98-02524
StatusExpired
Name US WEST
Site Address 619 W BANNOCK ST
Project NameAT&T BUILDING-1ST FL
Customer Number 
ePlanReviewNo
Description
To construct a 1,887q.ft. telephone switch equipment room on the 1st floor within an existing tel/com/equip/ area.This building is a partially fire sprinkled building with work in progress under separate permit to bring into compliance for qualifying as a fully sprinkled facility per Sec. 904.4, 1994 UBC. NOTE: Communication equipment areas can remain un-sprinkled within a sprinkled building if in compliance with Section 904.4,(4) for exclusive use, full 1-hour occupancy separation assembly & automatic smoke-detection system OR area is to be fully sprinkled. (P.C.#577-98)/ drs.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Receive PAYMENT IN FULL  11/17/1999 DONE
Fee Review-notes9/18/1998 4/23/1999 DONE
ADDITIONAL VALUES FROM SUB
INSP-Final Inspection4/5/19994/6/19994/6/1999PPASS
DetailsRick Jackson
###-#### occ approved
Letter of compliance  4/6/1999 PASS
Letter of Compliance #16546 issued 4-6-99.
INSP-Final Inspection3/3/19993/5/19993/5/1999PFAIL
DetailsRick Jackson
###-#### Dick call before going reschedule from 3/04 strobe not right cd; t-tapped wiring
INSP-Conference1/13/19991/13/19991/13/1999APART
DetailsRick Jackson
told contractor (Dick) to complete alarm notification circuits as shown on plans
INSP-Final Inspection1/11/19991/11/19991/11/1999AFAIL
DetailsRick Jackson
alarms not complete; recheck dampers
INSP - Final1/8/19991/8/19991/8/1999PPASS
Details
01/08/99 333 - fianll ok
INSP-Final Inspection1/8/19991/8/19991/8/1999PPASS
Details
01/08/99 333 - ffinal ik
INSP - Framing/Rough-in10/19/199810/19/199810/19/1998APASS
Details
10/19/98 333 - 1ST FLOOR--DICK ###-#### FRAM-OK FRAMING
INSP - Framing/Rough-in10/16/199810/19/199810/19/1998ACANC
DetailsDave Lightfoot
10/19/98 337 - dick ###-#### fr insp
Issue PAID IN FULL permit  10/2/1998
Plan assigned to (DRS)8/21/1998 10/1/1998 PASS
DetailsDan Stuart
Print Occupancy Form  10/1/1998
Inspection Record Card- Bld  10/1/1998
Telephone call  10/1/1998
called talked to bob smith ###-#### gave dollar amount
Print Pending Permit.LaserJet4  10/1/1998 PASS
PLANS/APPL TAKEN TO FRONT DESK  10/1/1998 PASS
Routing - PLAN CHECK9/22/1998 10/1/1998 PASS
Routing - FIRE9/29/1998 9/30/1998 PASS
alarm system requires plans - not in compliance on bld set
Plan resubmittals received  9/28/1998 PASS
Received response from architect, Bob Smith. Reviewed comments & plans with him at city office. Smoke detection & alarm system to comply with Fire Department regulations. Mr.Smith met with Floyd Varley to review plan deficiencies noted on F.D. plan review. Routing plans back to F. D. for second review.
Meeting  9/28/1998
Met with Bob Smith, Architect to review his response to plan review and his field analysis.
Routing - FIRE9/17/1998 9/22/1998 FAIL
Plan Review Completed(1st rev)  9/22/1998 FAIL
UBC & UFC issues
Plan resubmittals requested  9/17/1998 PEND
Faxed and mailed preliminary plan review comments to architect for response prior to issuance of permit. Forwarding plan to Fire Dept for their review and approval.
Print permit w/o conditions  9/17/1998 PEND
Routing - PLAN CHECK9/16/1998 9/17/1998 PEND
Plans sent to Fire Dept. while waiting for architects response.
Routing - PLAN CHECK8/21/1998 9/16/1998
Started plan review. Resubmittals required.
Plan routing begun/TENANTS  8/21/1998
Route to PLAN CHECK and FIRE.
Plan assigned to (MYS)8/19/1998 8/21/1998
DetailsMarlene Southard
Application received  8/19/1998
Recd Pcfee & Taken To Pln CK  8/19/1998
CHANGE STATUS TO (F)