BLD-Grading Inspection | 12/2/1999 | 12/2/1999 | 12/2/1999 | | BOND |
Rita DeYoung
|
|
|
Final grading complete. Revegetation not. Engineer has recommended a $500.00 surety to complete the revegetation. The final grading is conditionally approved upon receipt of this bond,
|
BLD-Final | 11/26/1999 | 11/29/1999 | 11/29/1999 | A | FAIL |
Tom Arcoraci
|
|
|
ron-- ###-#### fn occ Not ready.
|
BLD-Energy code compliance | 10/14/1999 | 10/15/1999 | 10/15/1999 | A | PASS |
Wes Worcester
|
|
|
RON ###-####
|
BLD-Framing/Rough-in | 10/14/1999 | 10/15/1999 | 10/15/1999 | A | PASS |
Wes Worcester
|
|
|
REINSPECT RON ###-####
|
BLD-Framing/Rough-in | 10/8/1999 | 10/11/1999 | 10/11/1999 | A | FAIL |
Russ Owen
|
|
|
RON ---###-#### RE-INSP FR stair need adjustment all sets
|
BLD-Framing/Rough-in | 10/6/1999 | 10/8/1999 | 10/8/1999 | A | FAIL |
Wes Worcester
|
|
|
###-#### need infilltration package and truss engineering
|
INSP - Foundation | 4/2/1999 | 4/2/1999 | 4/2/1999 | P | PASS |
Wes Worcester
|
|
|
04/02/99 342 - ###-#### JIM//FOUNDATION WALL 3:00 IF POSSIBLE
|
INSP - Foundation | 3/29/1999 | 3/30/1999 | 3/30/1999 | A | PASS |
Wes Worcester
|
|
|
03/30/99 342 - ###-#### JIM//FOOTING REINSPECTION
|
INSP - Foundation | 3/29/1999 | 3/29/1999 | 3/29/1999 | P | PART |
Wes Worcester
|
|
|
03/29/99 342 - footing\\\###-#### need engineer's letter
|
INSP - Foundation | 3/11/1999 | 3/12/1999 | 3/12/1999 | A | FAIL |
Tom Arcoraci
|
|
|
03/12/99 408 - issued cr notice on footing size
|
SUPER- Supervisor's review | 2/25/1999 | 2/25/1999 | 2/25/1999 | | PASS |
|
|
|
cONSTRUCTION WILL START WHEN WEATHER PERMITS.
|
Issue PAID IN FULL permit | | | 10/27/1998 | | |
|
|
|
|
Routing - PLAN CHECK | 9/24/1998 | | 10/8/1998 | | PASS |
|
|
|
|
Plan assigned to (DJO) | 8/31/1998 | | 10/8/1998 | | PASS |
Dan Overy
|
|
|
10/08/98 08:47:28 DJO - this action updated by action script from <<>> in Case No. BLD98-2673
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/8/1998 | | PASS |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 10/8/1998 | | PASS |
|
|
|
|
Plan Reviewer's activity | | | 10/8/1998 | | PASS |
|
|
|
engineering rec.
|
Inspection Record Card- Bld | | | 10/8/1998 | | |
|
|
|
|
Print Occupancy Form | | | 10/8/1998 | | |
|
|
|
|
Telephone call | | | 10/8/1998 | | |
|
|
|
called left message on machine gave dollar amounts for achd, swr. and bldg.
|
Plan Reviewer's activity | | | 9/30/1998 | | PEND |
|
|
|
ENGINEERING REQUIRED FOR LATERAL BRACING.
|
Plans ACCEPTED BY PLAN CHECK | | | 9/30/1998 | | PEND |
|
|
|
|
Routing - PLANNING | 9/23/1998 | | 9/23/1998 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 8/31/1998 | | 9/23/1998 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 9/22/1998 | | 9/22/1998 | | PASS |
Rita DeYoung
|
|
|
Approved as category 3. Redlined plan saying driveway must use existing driveway approach and not fill in drainage swale at the front of the lot.
|
Application received | | | 8/31/1998 | | |
|
|
|
|