SUPER- Supervisor's review | 6/9/1999 | 6/9/1999 | 6/9/1999 | | |
|
|
|
this project completed looks good
|
SUPER- Supervisor's review | 5/11/1999 | 5/11/1999 | 5/11/1999 | | |
|
|
|
all work completed wood removed from conceiled space c-o issued
|
Fee Review-notes | 3/3/1999 | | 4/26/1999 | | |
|
|
|
|
INSP - Final | 4/15/1999 | 4/15/1999 | 4/15/1999 | P | PASS |
Carl Dependahl
|
|
|
04/15/99 340 - Scheduled by Hello!. Contact phone is [3772870].; OK, CA
|
Permanent Occupancy | | 4/15/1999 | 4/15/1999 | | DONE |
|
|
|
|
Permanent occupancy | | | 4/15/1999 | | PASS |
|
|
|
Perm. Occ. Cert. #7744 issued 4-15-99 to the Banana Republic at Boise Towne Square.
|
INSP - Final | 4/13/1999 | 4/14/1999 | 4/14/1999 | P | NR |
Carl Dependahl
|
|
|
04/14/99 340 - mark ###-####; need elec, no insp
|
INSP-Final Inspection | 4/12/1999 | 4/13/1999 | 4/13/1999 | P | PASS |
Joe Tawney
|
|
|
04/13/99 406 - REINSP OK FOR PERM OCC
|
INSP - Final | 4/12/1999 | 4/12/1999 | 4/12/1999 | | NR |
Carl Dependahl
|
|
|
/ / 340 - CONF ONLY W/ ARCH RE EXIT DOORS
|
INSP-Final Inspection | 4/9/1999 | 4/12/1999 | 4/12/1999 | P | FAIL |
Joe Tawney
|
|
|
04/12/99 406 - FINAL FIRE FAIL DOOR HDWRE SPKLR PROT UNDER AHU
|
INSP-Conference | 4/6/1999 | 4/6/1999 | 4/6/1999 | | PART |
Joe Tawney
|
|
|
/ / 406 - CONF ON LOCATION OF FIRE EXT
|
SUPER- Supervisor's review | 3/30/1999 | 3/30/1999 | 3/30/1999 | | |
|
|
|
finish in progress. looks ok.
|
SUPER- Supervisor's review | 3/9/1999 | 3/9/1999 | 3/9/1999 | | |
|
|
|
sheetrock and tape completed in concieled space ok
|
INSP - Wall cover | 3/1/1999 | 3/2/1999 | 3/2/1999 | P | PART |
Carl Dependahl
|
|
|
03/02/99 340 - ok to encapsulate wood cubicles w gyp.
|
SUPER- Supervisor's review | 3/2/1999 | 3/2/1999 | 3/2/1999 | | |
|
|
|
reviewed non combustable requirements with rockers and securing sheetrock for fire resistnace
|
INSP - Wall cover | 3/2/1999 | 3/2/1999 | 3/2/1999 | P | |
|
|
|
###-#### Mark
|
INSP - Framing/Rough-in | 3/1/1999 | 3/1/1999 | 3/1/1999 | | FAIL |
Carl Dependahl
|
|
|
02/25/99 340 - c/n, need to verify alt method encapsulation wood at part
|
INSP - Framing/Rough-in | 2/25/1999 | 2/26/1999 | 2/26/1999 | P | FAIL |
|
|
|
02/26/99 338 - combustables not approved in the wall systems
|
INSP-Sprinkler Rough-in/Hydro | 2/19/1999 | 2/19/1999 | 2/19/1999 | | PART |
Joe Tawney
|
|
|
/ / 406 - OK TO COVER 130 SQ FT SPACING NEED RECALCS
|
INSP - Framing/Rough-in | 2/15/1999 | 2/16/1999 | 2/16/1999 | A | FAIL |
Carl Dependahl
|
|
|
02/16/99 340 - Scheduled by Hello!. Contact phone is [3772870]. c/n, se complete elec
|
INSP - Framing/Rough-in | 1/13/1999 | 1/13/1999 | 1/15/1999 | P | PART |
|
|
|
01/13/99 338 - made ok for conference on rated walls and tunnels
|
Issue PAID IN FULL permit | | | 12/29/1998 | | |
|
|
|
|
Inspection Record Card- Bld | | | 12/15/1998 | | |
|
|
|
|
Print Occupancy Form | | | 12/15/1998 | | |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 12/14/1998 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/14/1998 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 12/10/1998 | | 12/14/1998 | | PASS |
|
|
|
|
Plan assigned to (R_H) | 11/17/1998 | | 12/14/1998 | | PASS |
|
|
|
12/14/98 14:34:52 R_H - this action updated by action script from <<>> in Case No. BLD98-3519
|
Plan Review Completed(1st rev) | | | 12/9/1998 | | FAIL |
|
|
|
ubc issues
|
Routing - FIRE | 12/4/1998 | | 12/9/1998 | | PASS |
|
|
|
|
Plan resubmittals received | | | 12/8/1998 | | |
|
|
|
RECEIVED THREE COPIES OF REVISED SHEETS A-2.1, A-2.2, A-3.1, A-3.2, A-6.1, E-3.1, E-3.2, ROUTED TO RON H.
|
Routing - PLAN CHECK | 11/19/1998 | | 12/4/1998 | | |
|
|
|
|
Plan Reviewer's activity | | | 11/30/1998 | | FAIL |
|
|
|
Talked to project manager (architects represenitive) Carla Johnson, Faxed the requirements, will route to fire department,
|
Application received | | | 11/30/1998 | | PASS |
|
|
|
11-13-98 REQUIRES RECORD DECLARATION FORM. FAXED TO GARY PALMER AT ###-#### 11-30-98 RECEIVED RECORD DECLARATION FORM. PUT WITH PLANS AND FILE. KMM
|
Routing - PUBLIC WORKS | 11/17/1998 | | 11/18/1998 | | PASS |
|
|
|
|
Plan routing begun/TENANTS | | | 11/17/1998 | | |
|
|
|
Route to PUBLIC WORKS, PLAN CHECK and FIRE.
|
Plan assigned to (MYS) | 11/13/1998 | | 11/17/1998 | | |
Marlene Southard
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 11/13/1998 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 11/13/1998 | | |
|
|
|
|
SUPER- Supervisor's review | 4/6/1999 | | | | |
|
|
|
|