Permit Information
Permit NumberBLD98-03901
StatusFinaled
Name RAM PLAZA (BLDG #100)
Site Address 550 S BROADWAY AVE
Project NameRAM PLAZA BLD. #100
Customer Number 
ePlanReviewNo
Description
THE RAM PLAZA, BUILDING #100 (SHELL ONLY PERMIT)* TO CONSTRUCT A NEW 5,252 SQ. FT., ONE STORY, RETAIL SHELL BUILDING AND RELATED SITE IMPROVEMENTS. CONSTRUCTED OF A CONCRETE SLAB FLOOR, STRUCTURAL MASONRY AND METAL STUD EXTERIOR WALLS, STEEL INTERIOR COLUMNS, STEEL PREMANUFACTURED ROOF JOISTS AND GIRDERS AND METAL ROOF DECK WITH SINGLE-PLY ROOF SYSTEM AND SOME WOOD FRAME ROOF OVERBUILDS AT ENTRY AREAS. THIS BUILDING WILL BE FULLY FIRE SPRINKLED. THE SPRINKLERS ARE USED FOR ALLOWABLE AREA INCREASE. THIS BUILDING IS ONE OF THREE, ALL THREE HAVE BEEN REVIEWED AS ONE FOR ALLOWABLE AREA AND EXTERIOR WALL AND OPENING PROTECTION. THIS IS A SHELL PERMIT ONLY. THERE IS NO OCCUPANCY ALLOWED UNDER THIS PERMIT. A SEPARATE TENANT IMPROVEMENT PERMIT IS REQUIRED TO FINISH EACH SEPARATE TENANT SPACE. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED REQUIREMENT LIST. DRH98-0113/CVA98-0009/PC#878-98/JCM THIS PERMIT SUBMITTED ON ONE SET OF PLANS ALONG WITH BUILDINGS #200, AND #300.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  1/19/2005  
PubWorks Occupancy Approval  1/23/2001 DONE
Drainage project not inspected, not completed according to plans. Project complete as of 01/23/01. M.Strasser
Letter of compliance  1/14/2000 DONE
Letter of Compliance #18335 issued 1-14-00.
BLD-Final1/10/20001/10/20001/10/2000PPART
DetailsRuss Owen
Pending engineers approval of special inspection report.
BLD-Final1/6/20001/7/20001/7/2000PPART
DetailsRuss Owen
mike ###-#### call first to meet there. Need engineers approval of special inspection reports.
BLD-Framing/Rough-in9/17/19999/20/19991/7/2000APASS
DetailsRuss Owen
mike-- ###-#### fr insp
BLD-Final12/23/199912/23/199912/23/1999PFAIL
DetailsRuss Owen
Scheduled by a contractor via Hello! on 12/23/1999 at 08:46:09. Contact: ###-####. Need public works.
(F) Reprint permit  12/22/1999 DONE
FIRE-Final Inspection12/9/199912/10/199912/10/1999APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/09/1999 at 09:43:12. Contact: ###-####. Occupancy approved.
FIRE-Sprinkler Rough-in12/2/199912/2/199912/2/1999PFAIL
DetailsRick Jackson
alan ###-#### hydro stat test unit 100 Hydro okay; sway bracing not complete; FDC.
BLD-Conference11/23/199911/24/199911/24/1999APART
DetailsRuss Owen
Mike ###-#### Pre-inspection only.
BLD-Conference11/2/199911/3/199911/2/1999APART
DetailsRick Jackson
mike ###-#### conf insp Address problems; sprinkler issues.
Fee Review-notes1/12/1999 10/27/1999 DONE
final 214,757.00 difference this value was split 3 ways for all the permits. they gave me one lump sum. new cert proj 1,284,357.00 ele 42,868.00 plm 26,444.00 mec 35,201.00 these values covered all three shell permits 98-3901,3909,3910
Plan Reviewer's activity  10/6/1999 PASS
AT THE REQUEST OF THE ARCHITECT OF RECORD, KENNETH C. MILLO, THE CONSTRUCTIONS TYPE OF THIS BUILDING HAS BEEN CHANGED TO TYPE V-NONRATED WITH AUTOMATIC SPRINKLER SYSTEM BEING USED FOR ALLOWABLE AREA INCREASE. THE CONSTRUCTION TYPE WAS ORIGINALLY APPROVED AS TYPE II-NONRATED WITHOUT SPRINKLERS.
Inspection Record Card- Bld  10/6/1999 DONE
Print Occupancy Form  10/6/1999 DONE
BLD-Framing/Rough-in9/27/19999/27/19999/27/1999AFAIL
DetailsBob Archibald
Conference w/Mike at job site wood framing to cease and any wood framing will result in SWO of entire job. Framers pulled off roof.
BLD-Conference9/27/19999/27/19999/27/1999PFAIL
DetailsBob Archibald
Returned and Left phone message w/Scott that any wood framing would result in SWO.
BLD-Framing/Rough-in9/21/19999/21/19999/21/1999PPART
DetailsCarl Dependahl
###-#### mike upper parapet ok to cover center building.
INSP - Foundation5/14/19995/14/19995/14/1999PPART
DetailsRuss Owen
05/14/99 407 - special insp.ok.
INSP - Concrete5/10/19995/11/19995/11/1999APART
DetailsRuss Owen
05/11/99 407 - subject to special inspection.
INSP - Concrete5/6/19995/6/19995/6/1999PPART
DetailsRuss Owen
05/06/99 407 - rebar clearance needed,corrections being made,special ins
INSP - Foundation4/27/19994/28/19994/28/1999APART
DetailsRuss Owen
04/28/99 407 - ok subject to special inspector,who is on site now.
(F) Reprint permit  4/26/1999
Issue PAID IN FULL permit  4/21/1999
Print Occupancy Form  4/21/1999
Inspection Record Card- Bld  4/21/1999
Telephone call  4/21/1999
talked to roy faxed over copy of $ amounts for him to cut check
Plan assigned to (JCM)12/21/1998 4/20/1999 PASS
DetailsJohn Menard
Routing - PLAN CHECK3/30/1999 4/20/1999 PASS
PLANS/APPL TAKEN TO FRONT DESK  4/20/1999 PASS
Routing Off Site - STRUCTURAL4/12/1999 4/19/1999 PASS
CONTACTED PDQ TO TAKE OUT ADDITIONAL STRUC. COMMENT FOR RAM PLAZA PER JOHN M. KMM RECIEVED A FAX FROM THE CONSULTING ENGIEER INDICATING THAT ALL REQUIRED STRUCTURAL REVISIONS HAD BEEN ADEQUATELY ADDRESSED.
Plan Reviewer's activity  4/19/1999 PEND
HAVE REVIEWED AND APPROVED LAST RESUBMITTALS. THE PERMIT CAN BE ISSUED AFTER RECEIPT OF FINAL CERTIFICATE OF VALUE.
Plan resubmittals received  4/12/1999
RECEIVED TWO COPIES OF REVISED SHEETS S3.1, S1.1, S2.1, S7.1, S7.2 PLUS ONE COPY OF CALCS. FROM ALLEN MILLO ASSO. ROUTED TO JOHN M. KMM
Plan resubmittals requested  4/5/1999 PEND
FAXED MONTE CHAPIN AT ALLEN - MILLO ASSOCIATES REQUESTING ADDITIONAL REVISIONS NOT COMPLETED ON THE FIRST RESUBMITTAL.
Plan resubmittals received  4/2/1999 PEND
RECEIVED PLAN RESUBMITTALS FROM ALLEN MILLO ASSOCIATES, FORWARDED SAME JOHN MENARD. DAR 4/2/99
Routing - PLANNING3/16/1999 3/30/1999 PASS
approved per DRH98-0113.
Routing Off Site - STRUCTURAL3/15/1999 3/17/1999 FAIL
RESUBMITTALS SENT TO OUTSIDE STRUCTURAL ENGINEER. DAR 3/15/99
Plan resubmittals requested  3/17/1999 PEND
FAXED KENNETH MILLO A COPY OF THE CONSULTING STRUCTURAL ENGINEERS COMMENT LIST FOR THE LATEST STRUCTURAL RESUBMITTALS.
Routing - PUBLIC WORKS3/12/1999 3/15/1999 PASS
Routing - PLAN CHECK2/19/1999 3/12/1999
Plan resubmittals received  3/12/1999 PEND
RECEIVED PLAN RESUBMITTALS FROM ARMEN TAROIAN, FORWARDED SAME TO JOHN MENARD. DAR 3/12/99
Routing - PUBLIC WORKS2/18/1999 2/19/1999 FAIL
REQUIRES STREET LIGHT PLAN. BILL COLSON
Routing - PLAN CHECK2/5/1999 2/18/1999
Routing - FIRE2/2/1999 2/5/1999 PASS
Plan Review Completed(1st rev)  2/5/1999 FAIL
ubc, planning & PW fails
Routing - PLAN CHECK1/4/1999 2/1/1999
Plan resubmittals requested  1/11/1999 PEND
MAILED THE ARCHITECT A COPY OF THE COMMENT LIST REQUESTING REVISIONS.
Routing Off Site - STRUCTURAL12/22/1998 1/7/1999 FAIL
CONTACTED PDQ TO TAKE OUT TO OUTSIDE ENG. MUST WAIT FOR ENG. SET. CONTACTED RICHARD RAY TO LET HIM KNOW THAT I NEED AN ENG. SET. KMM RECEIVED OUTSIDE ENG. COPY. 12-22-98
Plan resubmittals requested  1/5/1999 PEND
FAXED KENNETH MILLO (ARCHITECT OF RECORD) A COPY OF THE COMMENT LIST FROM THE CONSULTING ENGINEER FOR REQUESTED STRUCTURAL CORRECTIONS.
Routing - PLUMBING12/30/1998 1/4/1999 PASS
Routing - PLANNING12/28/1998 12/30/1998 FAIL
Revised plans indicating compliance with Design Review conditions (DRH98-0113) must be submitted for review and approval. Phoned Ken Millo, architect, and discussed this with him.
Routing - PLANNING12/28/1998 12/29/1998 FAIL
AS PER VARIANCE CVA98-0009; Design Review conditions not met (per DRH98-0113).
Plan resubmittals received  12/28/1998
RECEIVED THREE COPIES OF SHEET S7.0 ROUTED ONE COPY TO OUTSIDE ENG. AND PUT COPY WITH OUT SET. KMM
Routing - PUBLIC WORKS12/22/1998 12/28/1998 FAIL
RERQUIRES STREET LIGHT PLAN PER BILL COLSON. SEWER STUB IS 6 INCH RATHER THAN 8 INCH PER JOHN JOHNSON. REQUIRES DRAINAGE PLAN REVISIONS AND CACULATIONS PER BRIAN MURPHY. 12/28/98 DAR
Plan routing begun/NEW & ADDTN  12/22/1998
Plans ACCEPTED BY PLAN TECH  12/21/1998 PASS
WAITING FOR OUTSIDE ENG. COPY. CONTACTED MR. RAY OF THIS NEED. KMM 12-22-98 received outside eng. copy. BUILDINGS
Received Certificate of Value  12/21/1998 PASS
Plan assigned to (MYS)12/18/1998 12/21/1998
DetailsMarlene Southard
Application received  12/18/1998 PASS
Recd Pcfee & Taken To Pln CK  12/18/1998