Permit Information
Permit NumberBLD98-03910
StatusFinaled
Name JEFF IVERSON
Site Address 590 S BROADWAY AVE
Project NameRAM PLAZA BLDG. #300
Customer Number 
ePlanReviewNo
Description
THE RAM PLAZA, BUILDING #300 (SHELL ONLY PERMIT) * TO CONSTRUCT A NEW 8,190 SQ. FT., ONE STORY, RETAIL SHELL BUILDING AND RELATED SITE IMPROVEMENTS. CONSTRUCTED OF A CONCRETE SLAB FLOOR, STRUCTURAL MASONRY AND METAL STUD EXTERIOR WALLS, STEEL INTERIOR COLUMN, STEEL PREMANUFACTURED ROOF JOISTS AND GIRDERS AND METAL ROOF DECK WITH SINGLE-PLY ROOFING SYSTEM AND SOME WOOD FRAME OVERBUILDS AT THE ENTRY AREAS. THIS BUILDING WILL BE FULLY FIRE SPRINKLED. THE SPRINKLERS ARE BEING USED FOR ALLOWABLE AREA INCREASE. THIS BUILDING IS ONE OF THREE, ALL THREE HAVE BEEN REVIEWED AS ONE FOR ALLOWABLE AREA AND EXTERIOR WALL AND OPENING PROTECTION REQUIREMENTS. THIS IS A SHELL PERMIT ONLY. THERE IS NO OCCUPANCY ALLOWED UNDER THIS PERMIT. A SEPARATE TENANT IMPROVEMENT PERMIT IS REQUIRED TO FINISH EACH SEPARATE TENANT SPACE. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED REQUIREMENT LIST. DRH98-0113/CVA98-0009/PC#880-98/JCM PERMIT SUBMITTED ON ONE SET OF PLANS ALONG WITH BUILDINGS #100, AND #200
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Letter of compliance  1/14/2000 DONE
Letter of Compliance #18334 issued 1-14-00.
BLD-Final1/10/20001/10/20001/10/2000PPART
DetailsRuss Owen
Pending engineers approval of special inspection report.
(F) Reprint permit  12/22/1999 DONE
FIRE-Final Inspection12/9/199912/10/199912/10/1999APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/09/1999 at 09:45:53. Contact: ###-####. Occupancy approved.
FIRE-Sprinkler Rough-in12/2/199912/2/199912/2/1999PFAIL
DetailsRick Jackson
unit 300 alan ###-#### hydro stat test Hydro fail; sway bracing; ball drip for FDC.
Plan resubmittals received  11/24/1999 PEND
Received plan resubmittals (Gas piping for building 300 from Elkhorn Engineers), forwarded same to David Lightfoot. 11/24/99 DAR
FIRE-Conference11/3/199911/3/199911/3/1999APART
DetailsRick Jackson
Addressing problems; sprinkler issues.
BLD-Framing/Rough-in10/29/199911/1/199911/1/1999APASS
DetailsRuss Owen
MIKE ###-####
BLD-Framing/Rough-in10/26/199910/27/199910/27/1999AFAIL
DetailsTom Arcoraci
###-#### No super. On site
Fee Review-notes12/22/1998 10/27/1999 DONE
214,757.00 additional value was split 3 ways value from gc
BLD-Framing/Rough-in10/15/199910/15/199910/15/1999PFAIL
DetailsRuss Owen
mike-- ###-#### fr insp left correction on job trailer window
Plan Reviewer's activity  10/6/1999 PASS
AT THE REQUEST OF THE ARCHITECT OF RECORD, KENNETH C. MILLO, THE CONSTRUCTION TYPE OF THIS BUILDING IS HAS BEEN CHANGED TO TYPE V-NONRATED WITH AUTOMATIC SPRINKLER SYSTEM BEING USED FOR ALLOWABLE AREA INCREASE. THE CONSTRUCTION TYPE WAS ORIGINALLY APPROVED AS TYPE II-NONRATED WITHOUT SPRINKLERS.
Inspection Record Card- Bld  10/6/1999 DONE
Print Occupancy Form  10/6/1999 DONE
INSP - Framing/Rough-in9/14/19999/15/19999/15/1999APASS
DetailsRuss Owen
BLDG 300 OK TO COVER UPPER PARAPET
INSP - Framing/Rough-in9/13/19999/14/19999/14/1999AFAIL
DetailsRuss Owen
SAME CORRECTIONS, MORE SCREWS ETC.
INSP - Framing/Rough-in9/13/19999/13/19999/13/1999PFAIL
DetailsRuss Owen
NEEDS MORE SCREWS AND FASTENERS ON EXT UPPER PARAPETS. ALSO TALKED W STEED ABOUT JOB CONSTRUCTION TYPE AND TOLD THEM TO CONTACT ARCHITECT ABOUT REVISIONS
INSP - Framing/Rough-in9/8/19999/8/19999/8/1999PPART
DetailsRuss Owen
MIKE ###-####; 9/8 Talked w architect about requirements for Type IIN construction, roof over framing on plan doesn't comply, as told at plan check. jrb
INSP - Framing/Rough-in9/7/19999/7/19999/7/1999 FAIL
DetailsRuss Owen
9-7 Need change from architect for ext parapet walls. JRB;
INSP - Framing/Rough-in8/23/19998/24/19998/24/1999APART
DetailsRuss Owen
08/24/99 407 - ok per special inspection.
INSP - Concrete8/3/19998/3/19998/3/1999PPART
DetailsRuss Owen
08/03/99 407 - subject to special inspection.
INSP - Framing/Rough-in7/27/19997/27/19997/27/1999PPART
DetailsRuss Owen
07/27/99 407 - subjects to a special inspection.
INSP - Foundation7/21/19997/22/19997/22/1999APART
DetailsRuss Owen
07/22/99 407 - subject to special inspection.
INSP - Concrete7/8/19997/8/19997/8/1999PPASS
DetailsRuss Owen
07/08/99 407 - special inspector will approve.
INSP - Concrete7/6/19997/7/19997/7/1999APART
DetailsRuss Owen
07/07/99 407 - subject to special inspector.
INSP - Concrete7/1/19997/2/19997/2/1999APART
DetailsRuss Owen
07/02/99 407 - ok mti on site,has approvred pouring grout.
INSP - Framing/Rough-in6/30/19996/30/19996/30/1999PPART
DetailsRuss Owen
06/30/99 407 - special inspection letter to folow.
INSP - Foundation6/25/19996/28/19996/28/1999APART
DetailsRuss Owen
06/28/99 407 - masonary rebar grout at 1pm Mike ###-####,subject to spec
INSP - Concrete6/23/19996/24/19996/25/1999PPART
DetailsRuss Owen
06/24/99 407 - ok special inspector ,has approved,meet with at site.
INSP - Concrete6/16/19996/16/19996/16/1999PPART
DetailsRuss Owen
06/16/99 407 - subject to special inspection.
INSP - Concrete6/10/19996/11/19996/11/1999APART
DetailsRuss Owen
06/11/99 407 - special inspection.
INSP - Foundation6/10/19996/10/19996/10/1999PPART
DetailsRuss Owen
06/10/99 407 - Mike ###-####
INSP - Foundation6/3/19996/4/19996/4/1999PPART
DetailsRuss Owen
06/04/99 407 - ok per special inspection.
INSP - Foundation5/27/19995/28/19995/28/1999APART
Details
05/28/99 338 - MADE OK TO POUR FOUND WITH SP INSP APPROVAL
INSP - Foundation5/24/19995/24/19995/24/1999PPART
DetailsRuss Owen
05/24/99 407 - pour subjects to special inspection.
INSP - Foundation5/20/19995/21/19995/21/1999PPART
DetailsRuss Owen
05/21/99 407 - ok per special inspector.
(F) Reprint permit  4/26/1999
Issue PAID IN FULL permit  4/21/1999
Print Occupancy Form  4/21/1999
Telephone call  4/21/1999
faxed over to roy
Inspection Record Card- Bld  4/21/1999
Plan assigned to (JCM)12/21/1998 4/20/1999 PASS
DetailsJohn Menard
Routing - PLAN CHECK3/30/1999 4/20/1999 PASS
PLANS/APPL TAKEN TO FRONT DESK  4/20/1999 PASS
Routing Off Site - STRUCTURAL4/12/1999 4/19/1999 PASS
CONTACTED PDQ TO TAKE ADDITIONAL STRUCTURAL COMMENT FOR RAM PLAZA TO OUTSIDE ENG. PER JOHN M. KMM
Plan Reviewer's activity  4/19/1999 PEND
REVIEWED AND APPROVED RESUBMITTALS. PERMIT CAN ISSUED AFTER RECEIPT OF THE FINAL CERTIFICATE OF VALUE.
Plan resubmittals received  4/12/1999
RECEIVED TWO COPIES OF REVISED SHEETS S3.1, S1.1, S2.1, S7.1, S7.2 PLUS ONE COPY OF CALCS. FROM ALLEN MILO ASSOC. ROUTED TO JOHN M. KMM
Plan resubmittals requested  4/5/1999 PEND
FAXED MONTE CHAPIN REQUESTING REVISIONS NOT COMPLETED ON THE FIRST RESUBMITTALS.
Plan resubmittals received  4/2/1999 PEND
RECEIVED PLAN RESUBMITTALS FROM ALLEN * MILLO, FORWARDED SAME TO JOHN MENARD. DAR 4/2/99
Routing - PLANNING3/16/1999 3/30/1999 PASS
approved per DRH98-0113.
Routing Off Site - STRUCTURAL3/15/1999 3/17/1999 FAIL
SENT RESUBMITTALS TO OUTSIDE STRUCTURAL ENGINEER. DAR 3/15/99
Routing - PUBLIC WORKS3/12/1999 3/16/1999 PASS
Routing - PLAN CHECK2/19/1999 3/12/1999
Plan resubmittals received  3/12/1999 PEND
RECEIVED PLAN RESUBMITTALS FROM ARMEN TAROIAN, FORWARDED SAME TO JOHN MENARD. DAR 3/12/99
Routing - PUBLIC WORKS2/18/1999 2/19/1999 FAIL
REQUIRES STREET LIGHT PLAN.
Routing - PLAN CHECK2/5/1999 2/19/1999
Routing - FIRE2/2/1999 2/5/1999 PASS
sprinklers if requied will be under separate permit
Plan Review Completed(1st rev)  2/5/1999 FAIL
ubc, pw and planning failure
Routing - PLAN CHECK1/4/1999 2/1/1999
Plan resubmittals requested  1/11/1999 PEND
MAILED KENNETH MILLO (ARCHITECT OF RECORD) A COPY OF THE COMMENT LIST REQUESTING REVISIONS.
Routing Off Site - STRUCTURAL12/22/1998 1/7/1999 FAIL
CONTACTED RICHARD RAY FOR OUTSIDE ENG. COPY. CONTACTED PDQ TO TAKE PLANS OUT TO OUTSIDE ENG. 12-22-98 RECEIVED ENG. COPY
Plan resubmittals requested  1/5/1999 PEND
FAXED KENNETH MILLO (ARCHITECT OF RECORD) A COPY OF THE CONSULTING ENGINEER'S COMMENT LIST REQUESTING REVISIONS.
Routing - PLUMBING12/30/1998 1/4/1999 PASS
Routing - PLANNING12/28/1998 12/30/1998 FAIL
PER DRH98-0113 SEE MEMO IN BLD98-3901 FOR REASON FOR FAILURE.
Routing - PLANNING12/28/1998 12/29/1998 PASS
PER VARIANCE CVA98-0009
Plan resubmittals received  12/28/1998
RECEIVED THREE COPIES OF SHEETS S7.0. PUT ONE COPY TO OUTSIDE ENG. AND PUT TWO COPIES WITH INHOUSE SET. KMM
Routing - PUBLIC WORKS12/22/1998 12/28/1998 FAIL
SEE BLD98-3901
Plan routing begun/NEW & ADDTN12/22/1998 12/22/1998
Received Certificate of Value  12/21/1998 PASS
Application received  12/18/1998 PASS
Plans ACCEPTED BY PLAN TECH  12/18/1998 PASS
CONTACTED RAY RICHARD TO LET HIM KNOW THAT WE NEED OUTSIDE ENG. SET. 12-22-98 RECEIVED OUTSIDE ENG. COPY