Receive PAYMENT IN FULL | | | 4/19/2000 | | DONE |
|
|
|
|
(F) Reprint permit | | | 2/10/2000 | | DONE |
|
|
|
|
Fee Review-notes | 4/30/1999 | | 9/17/1999 | | DONE |
|
|
|
additional fees from subs
|
Permanent Occupancy | | 9/17/1999 | 9/17/1999 | | DONE |
|
|
|
|
BLD-Final | 9/16/1999 | 9/17/1999 | 9/17/1999 | A | PASS |
Carl Dependahl
|
|
|
|
Permanent occupancy | | | 9/17/1999 | | DONE |
|
|
|
Perm. Occ. Cert. #7901 issued 9-17-99 to the Goodwood Barbecue.
|
INSP-Final Inspection | 9/2/1999 | 9/3/1999 | 9/3/1999 | A | PASS |
Rick Jackson
|
|
|
follow-up inspection - air balance report okay; occ approved
|
INSP - Final | 8/27/1999 | 8/30/1999 | 8/30/1999 | A | FAIL |
Carl Dependahl
|
|
|
08/30/99 340 - ROB ###-#### FINAL; c/n , listing for firestops, other ag
|
INSP-Final Inspection | 8/20/1999 | 8/20/1999 | 8/20/1999 | | PART |
Joe Tawney
|
|
|
08/20/99 406 - FINAL OK FOR TEMP OCC
|
INSP - Framing/Rough-in | 8/16/1999 | 8/17/1999 | 8/17/1999 | A | FAIL |
Carl Dependahl
|
|
|
08/17/99 340 - FIRE WALL INSP. ROB ###-####; c/n, need listing & proper
|
Code Occupancy Approval | | | 8/17/1999 | | |
|
|
|
Temporary requested by Rob ###-####
|
INSP-Final Inspection | 8/12/1999 | 8/16/1999 | 8/16/1999 | P | FAIL |
Joe Tawney
|
|
|
08/16/99 406 - FINAL FAIL C/N ISSUED
|
INSP - Framing/Rough-in | 8/9/1999 | 8/10/1999 | 8/10/1999 | P | FAIL |
Carl Dependahl
|
|
|
08/10/99 340 - CHRIS ###-#### FIRE WALL; keep c/n firestops
|
INSP - Framing/Rough-in | 7/23/1999 | 7/26/1999 | 7/26/1999 | A | FAIL |
Carl Dependahl
|
|
|
07/26/99 340 - fire shafts Rob ###-####; c/n, need listing for "fire tap
|
INSP - Framing/Rough-in | 6/22/1999 | 6/22/1999 | 6/22/1999 | P | PART |
Carl Dependahl
|
|
|
06/22/99 340 - rec'd eng's letter for stud repair at brg wall. ok; keep
|
INSP - Framing/ Rough-in | 6/17/1999 | 6/17/1999 | 6/17/1999 | | FAIL |
Carl Dependahl
|
|
|
/ / 340 - AWAITING DETAIL AT OCCUPANCY SEPARATION. KEEP CN
|
SUPER- Supervisor's review | 6/16/1999 | 6/16/1999 | 6/16/1999 | | PEND |
|
|
|
Conference on plan review requirements.
|
INSP - Framing/ Rough-in | 6/16/1999 | 6/16/1999 | 6/16/1999 | | FAIL |
Carl Dependahl
|
|
|
/ / 340 - CONF ONLY, KEEP C/N
|
INSP - Energy code compliance | 6/14/1999 | 6/15/1999 | 6/15/1999 | A | FAIL |
Carl Dependahl
|
|
|
06/15/99 340 - Chris ###-####; need arch's detail for ??occ. separation?
|
INSP - Energy code compliance | 6/11/1999 | 6/14/1999 | 6/14/1999 | P | FAIL |
Carl Dependahl
|
|
|
06/14/99 340 - ###-#### CHRIS//INSULATION
|
INSP - Framing/Rough-in | 6/8/1999 | 6/9/1999 | 6/10/1999 | P | PART |
Carl Dependahl
|
|
|
06/09/99 340 - ###-#### CHRIS//FRAMING GOODWOOD BBQ; REC'D ENGS FIX, OK
|
INSP - Framing/Rough-in | 5/28/1999 | 5/28/1999 | 5/28/1999 | | FAIL |
Carl Dependahl
|
|
|
06/02/99 340 - [3717151]. c/n, overbored studs, anchors,addsheating at i
|
INSP - Framing/Rough-in | 5/28/1999 | 5/28/1999 | 5/28/1999 | P | FAIL |
Carl Dependahl
|
|
|
[3717151].
|
INSP - Framing/Rough-in | 5/24/1999 | 5/24/1999 | 5/24/1999 | P | FAIL |
|
|
|
05/24/99 338 - no coordination between gen and the framing sub
|
INSP - Foundation | 4/8/1999 | 4/9/1999 | 4/9/1999 | P | |
Russ Owen
|
|
|
###-#### GOODWOOD BBQ
|
PLACE HOLD ON JOB | | 4/8/1999 | 4/8/1999 | | HOLD |
|
|
|
Needs to be released by Planning Department
|
INSP - Foundation | 4/6/1999 | 4/7/1999 | 4/7/1999 | A | PART |
Carl Dependahl
|
|
|
04/07/99 340 - footing ###-#### chris; part, ext ftgs, need int w/ walls
|
(F) Reprint permit | | | 3/19/1999 | | |
|
|
|
|
Plan assigned to (ADS) | 2/1/1999 | | 3/17/1999 | | PASS |
|
|
|
03/17/99 13:38:13 ADS - this action updated by action script from <<>> in Case No. BLD99-0280
|
Routing - PLAN CHECK | 2/25/1999 | | 3/17/1999 | | PASS |
|
|
|
Survey recorded 12 Mar.1999, Survey #4561, Inst.#99024419.
|
Inspection Record Card- Bld | | | 3/17/1999 | | |
|
|
|
|
Print Occupancy Form | | | 3/17/1999 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/17/1999 | | PASS |
|
|
|
|
Issue PAID IN FULL permit | | | 3/17/1999 | | |
|
|
|
|
Routing Off Site - STRUCTURAL | 3/4/1999 | | 3/5/1999 | | PASS |
|
|
|
contacted pdq to take response to structual plan review comments to outside eng. kmm Approved 5 mar ads
|
Plan resubmittals received | | | 3/5/1999 | | |
|
|
|
RECEIVED TWO COPIES OF STAMPED AND SIGNED REVISED SHEETS ROUTED TO ARLAN. KMM
|
Plan resubmittals received | | | 3/4/1999 | | |
|
|
|
RECEIVED TWO COPIES OF REVISED DRAWING SHEETS G0.1, A1.1, A2.1, A2.3, A2.4, A3.1, A3.2, A5.1, A7.1, A8.1, A8.2, S1, S2, S3, S4. ONE COPY OF RESPONSE TO PLANS REVIEW REPORT. ONE COPY OF RESPONSE LETTER TO STRUCTURAL REVIEW. TWO COPIES OF SUPPLEMENTAL CALCULATIONS. ONE COPY OF LETTER FROM EISI. AND ONE RESPONSE TO PLAN REVIEW REPPORT (FIRE DEPT.) ROUTED TO ARLAN S. KMM
|
Routing Off Site - A.C.H.D | 3/1/1999 | | 3/1/1999 | | PASS |
|
|
|
cert. #99-4630 paid through achd
|
Routing - FIRE | 2/22/1999 | | 2/24/1999 | | PASS |
|
|
|
|
Plan Review Completed(1st rev) | | | 2/24/1999 | | FAIL |
|
|
|
UBC issues
|
Routing Off Site - STRUCTURAL | 2/1/1999 | | 2/19/1999 | | FAIL |
|
|
|
CONTACTED PDQ TO TAKE PLANS OUT TO ENG. KMM 2-4-99 OUT SIDE ENG. CALLED AND REQUESED AN S2 SHEET. IT WAS LEFT OUT OF THEIR SUBMITTAL. ARLAN TOOK A SHEET FROM OUT SUB. AND WILL CALL ARCHITECT FOR ANOTHER FOR OUR COPIES. I WILL CONTACT PDQ TO TAKE THIS S2 SHEET OUT TO ENG. KMM
|
Routing - PLANNING | 2/9/1999 | | 2/19/1999 | | PASS |
|
|
|
APPROVED PER DRH98-0195, AND AS NOTED ON SHEET L-1 FOR 2 ADDITIONAL CLASS II TREES ALONG SPECTRUM WAY.
|
Routing - PLAN CHECK | 2/19/1999 | | 2/19/1999 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 2/19/1999 | | FAIL |
|
|
|
Stuctural correction - letter & list faxed & mailed to architect.
|
Plan resubmittals requested | | | 2/19/1999 | | FAIL |
|
|
|
correction list mailed & faxed to architect for non structural review
|
Routing - PLUMBING | 2/5/1999 | | 2/9/1999 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 2/1/1999 | | 2/5/1999 | | PASS |
|
|
|
|
Plan resubmittals requested | | | 2/4/1999 | | |
|
|
|
call Tom @ Architects office - asked for one copy of sheet S2. It was missing from 1 set of plans.
|
Recd Pcfee & Taken To Pln CK | | | 2/1/1999 | | |
|
|
|
|
Plan assigned to (MYS) | 2/1/1999 | | 2/1/1999 | | PASS |
Marlene Southard
|
|
|
|
Application received | | | 2/1/1999 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 2/1/1999 | | PASS |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 2/1/1999 | | PASS |
|
|
|
|
Received Certificate of Value | | | 2/1/1999 | | PASS |
|
|
|
|
Routing Off Site - C.D.H | 1/29/1999 | | 1/29/1999 | | PASS |
|
|
|
|