BLD-Framing/Rough-in | 12/16/1999 | 12/16/1999 | 12/16/1999 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 12/16/1999 at 09:42:58. Contact: ###-####. Done by others already.
|
BLD-Energy code compliance | 12/16/1999 | 12/16/1999 | 12/16/1999 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 12/16/1999 at 09:44:30. Contact: ###-####. Done by others already.
|
INSP - Final | 7/15/1999 | 7/15/1999 | 7/15/1999 | P | PASS |
Tom Arcoraci
|
|
|
07/15/99 408 - DON ###-####
|
INSP - Final | 7/12/1999 | 7/12/1999 | 7/12/1999 | | FAIL |
Tom Arcoraci
|
|
|
/ / 408 -
|
INSP - Final | 7/12/1999 | 7/12/1999 | 7/12/1999 | P | FAIL |
Carl Dependahl
|
|
|
07/12/99 340 - DON ###-#### nr, gave to 408
|
INSP - Framing/Rough-in | 4/1/1999 | 4/1/1999 | 4/1/1999 | | PASS |
Tom Arcoraci
|
|
|
/ / 408 -
|
INSP - Energy code compliance | 3/31/1999 | 3/31/1999 | 3/31/1999 | P | PASS |
Tom Arcoraci
|
|
|
03/31/99 408 - Don ###-####
|
INSP - Framing/Rough-in | 3/29/1999 | 3/30/1999 | 3/30/1999 | A | FAIL |
Russ Owen
|
|
|
03/30/99 407 - LEFT CORRECT.
|
INSP - Energy code compliance | 3/18/1999 | 3/19/1999 | 3/19/1999 | A | PASS |
Jim Sly
|
|
|
03/19/99 316 - Done by Alan H.
|
INSP - Framing/Rough-in | 3/15/1999 | 3/16/1999 | 3/16/1999 | A | FAIL |
Jim Sly
|
|
|
03/16/99 316 - NR and Need appr plans.
|
INSP - Framing/Rough-in | 3/16/1999 | 3/16/1999 | 3/16/1999 | P | PART |
Jim Sly
|
|
|
03/16/99 316 - Shear wall OK
|
INSP - Foundation | 2/17/1999 | 2/18/1999 | 2/18/1999 | A | PART |
Jim Sly
|
|
|
02/18/99 316 - Foot/bar appears OK
|
INSP - Foundation | 2/17/1999 | 2/17/1999 | 2/17/1999 | P | FAIL |
Jim Sly
|
|
|
02/17/99 316 - NR...Excavated but no forms, plans, or humans on site.
|
Issue PAID IN FULL permit | | | 2/17/1999 | | |
|
|
|
|
Plan assigned to (DJO) | 2/5/1999 | | 2/16/1999 | | PASS |
Dan Overy
|
|
|
02/16/99 11:09:01 DJO - this action updated by action script from <<>> in Case No. BLD99-0332
|
Telephone call | | | 2/16/1999 | | PASS |
|
|
|
talked to dave to verify plans are ready
|
Print Pending Permit.LaserJet4 | | | 2/16/1999 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/16/1999 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 2/16/1999 | | |
|
|
|
|
Plan Reviewer's activity | | | 2/16/1999 | | PASS |
|
|
|
received new plans and engineering. no engineering provided for whats happening in garage with hd2a holdowns and etc. will issue under conditions that this area will be addressed and submitted to inspector.
|
Plan Reviewer's activity | | | 2/10/1999 | | PEND |
|
|
|
HAVE CALLED DESIGNER AND CONTRACTOR. NO ENGINEERING TO BACK UP HOLDOWNS INDICATED ON PLANS. LOCATIONS OF HOLDOWNS ON FOUNDATION PLAN DO NOT MATCH WALL ON FLOOR PLAN. ALSO FLOOR PLAN INDICATES ADDITIONAL HOLDOWNS IN GARAGE THAT ARE NOT SHOWN ON FOUNDATION PLAN. MAJOR FAILURE ON INTERIOR DIMENSIONAL LOAD BRG. HDRS. GARAGE WING WALLS ONLY DEVELOP APPROX. A 15" PANEL. WILL KEEP PLANS ON HOLD UNTIL DESIGNER AND CONTRACTOR BRING IN CHANGES.
|
Plans ACCEPTED BY PLAN CHECK | | | 2/10/1999 | | PEND |
|
|
|
|
Routing - PUBLIC WORKS | 2/5/1999 | | 2/8/1999 | | PASS |
|
|
|
|
Application received | | | 2/5/1999 | | |
|
|
|
|
Routing - PLANNING | 2/5/1999 | | 2/5/1999 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 2/8/1999 | | | | PEND |
|
|
|
|