Permit Information
Permit NumberBLD99-01508
StatusFinaled
Name HEWLETT PACKARD (BLDG #1)
Site Address 11311 W CHINDEN BLVD
Project NameHP #1 - AUDITORIUM
Customer Number 
ePlanReviewNo
Description
To remodel the existing 2,513 sq.ft. auditorium per approved plans on file. Work to include removal of existing interior rooms & finishes per demo permit allready issued, BLD99-1414. To furr out East and West walls of auditorium & storage / counter area of South wall to create an assembly seating area of 2,093 square feet or less with a maximum occupant load of "299" to maintain the "A-3" assembly occupancy classification. Framing to be sheetrocked prior to finish applications. To install new suspended ceiling system, electrical, mechanical and fire sprinkler system upgrades to meet current codes. All per approved plans on file with notes & attachments. NOTE: This building is fully fire sprinklered for area increase. (P.C.#393-99)/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes5/24/1999 3/22/2000 DONE
Letter of compliance  1/27/2000 DONE
Letter of Compliance #18349 issued 1-27-00.
Receive PAYMENT IN FULL  11/8/1999 DONE
Letter of compliance  10/19/1999 DONE
Letter of Compliance #17934 issued 10-19-99.
Temporary occupancy  9/13/1999 PART
Temp. Occ. Cert. #3919 issued 9-13-99 to H-P (auditorium remodel).
INSP - Final8/30/19998/31/19998/31/1999APASS
DetailsTom Arcoraci
08/31/99 408 - ok for perm occ
INSP-Final Inspection8/26/19998/27/19998/27/1999PPASS
DetailsJoe Tawney
09/01/99 406 - REINSP OK FOR CERT OF COMPLETION/OCC
INSP - Final8/23/19998/25/19998/25/1999ACANC
DetailsTom Arcoraci
08/25/99 408 - JAY ###-####
INSP-Final Inspection8/19/19998/24/19998/24/1999PFAIL
DetailsJoe Tawney
09/01/99 406 - FINAL FAIL C/N ISSUED
INSP - Framing/Rough-in8/17/19998/18/19998/18/1999APART
DetailsCarl Dependahl
08/18/99 340 - dave ###-####; FURRED WALL OK, CHK CLG AT FINAL
INSP-Final Inspection8/16/19998/17/19998/17/1999PFAIL
DetailsJoe Tawney
08/17/99 406 - FINAL FAIL C/N ISSUED
INSP - Framing/Rough-in8/17/19998/17/19998/17/1999PCANC
DetailsTom Arcoraci
08/17/99 408 - will recall
Print Occupancy Form  7/1/1999
Issue & PRINT FEE-DUE permit  7/1/1999
Inspection Record Card- Bld  7/1/1999
Routing - PLAN CHECK6/30/1999 6/30/1999 PASS
Received plans back from fire dept plan review approved as noted. Processing for issuance of permit.
Plan Review Completed(1st rev)  6/30/1999
PLANS/APPL TAKEN TO FRONT DESK  6/30/1999 PASS
Routing to permit desk for processing.
Additional plans submitted  6/30/1999
Received requested floor plan copy designating the clear room size dimensions to be used by the contractor and verified by the structural inspector to keep auditorium with in allowable area for an A-3 occupancy. Attached copy to plans.
Routing - PLAN CHECK6/29/1999 6/30/1999 PASS
Architect & HP reduced the size of the auditorium to be 2093 s.f. or less for seating area by showing new walls on interior of room to reduce overall width and by extending storage area on south thereby the existing A3 occupancy status will remain and all the construction upgrade for fire-resistance and exit system modification go away. Plans approved and routed to fire dept for review.
Routing - FIRE6/30/1999 6/30/1999 PASS
HAVE CONDITIONS BEFORE INSTALL ON COMBUSTIBLES IN CAVITY.
Plan assigned to (DRS)6/3/1999 6/30/1999 PASS
DetailsDan Stuart
06/30/99 17:20:47 DRS - this action updated by action script from <<>> in Case No. BLD99-1508
Print Pending Permit.LaserJet4  6/29/1999
Routing to fire code plan review.
Plan resubmittals received  6/29/1999 PASS
New submittals received changing assembly area to continue use as exists - A3 occupancy max. 299 occupant load - to be posted in room per code section 1007.2.6 UBC
Plan resubmittals received  6/29/1999 PEND
RECEIVED PLAN RESUBMITTALS FROM LOMBARD CONRAD, FORWARDED SAME TO DAN STUART. DAR 6/29/99
Telephone call  6/28/1999
Call from Scott Henson to question plan review. I expalined to him and suggested he go to HP and suggest the area be reduced to allow continuing occupancy group of A-3 as currently exists and remove a mountain of trouble to upgrade an existing assembly area which is located centrally and will require major modifications to the exit system to go forward as proposed.
Meeting  6/28/1999 HOLD
Met with Scott Henson to review the requirements noted on plan review comments & how to address them if the area is reduced to maintain the A-3 occupancy. Most of the requirements will go away if the occupancy group is not changed. Scott to resubmit plans showing method of area reduction and maximum allowable area. All one-hour construction requirements will then go away.
Plan resubmittals requested  6/24/1999 FAIL
Plans incomplete for proposed occupancy group change. Exit system upgrade specified for this type of assembly occupancy was not addressed on submitted plans. Copy of prliminary review sent to architect with suggestion that area of assembly be reduced by 167 s.f. to 2,093 s.f. or less w/ 299 occ. load to maintain the A3 occupancy and avoid required upgrades. Plans submitted indicate a maximum desired minimum seating of 184 which can easily be achieved by reducing the area
Routing - PLAN CHECK6/4/1999 6/22/1999 FAIL
Plans on hold - rejected. Not designed for A2.1 as to type of construction, occupancy separation or exiting.
Plan routing begun/TENANTS  6/4/1999
Route to PLAN CHECK and FIRE.
Plan assigned to (MYS)5/24/1999 6/3/1999
DetailsMarlene Southard
Plans ACCEPTED BY PLAN TECH  5/25/1999 PASS
Received Certificate of Value  5/25/1999 KPAS
Application received  5/24/1999