Permit Information
Permit NumberBLD99-02286
StatusFinaled
Name NEIL BOEL, FACILITIES MANAGER
Site Address 707 N ARMSTRONG AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
To remodel a portion of an existing office area within the Northern-most wing - Tenant Zone 2 - by removing interior nonbearing walls to create an open office area; to relocate an office wall & doorway to be in line with adjacent spaces; remove & infill door opening; add new door to existing office area; construct new walls & entry to create new private office. If glazing is left in place as sidelights to doors, verify safety glass. If glass removed, infill with materials matching existing construction. All per approved plans, notes, attachments and past records on file. NOTE: This building is fully sprinkled; zoned by tenant separation walls into separate tenant areas & has smoke detectors in corridors. Rated corridors are not required at this time. PC#99-592/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Letter of compliance  12/8/1999 DONE
Letter of Compliance #18200 issued 12-8-99.
FIRE-Final Inspection11/3/199911/4/199911/4/1999APASS
DetailsJoe Tawney
Scheduled by a contractor via Hello! on 11/03/1999 at 16:09:05. Contact: ###-####. Reinsp. Ok for cert. Of completion.
BLD-Framing/Rough-in11/3/199911/4/199911/4/1999PFAIL
DetailsJim Sly
Scheduled by a contractor via Hello! on 11/03/1999 at 16:11:31. Contact: ###-####. Cancelled by contractor.
FIRE-Final Inspection10/31/199911/1/199911/1/1999AFAIL
DetailsJoe Tawney
Scheduled by a contractor via Hello! on 10/31/1999 at 15:08:03. Contact: ###-####. Reinsp. Was trying to schedule structural inspection on Hello system.
BLD-Framing/Rough-in11/1/199911/1/199911/1/1999PPART
DetailsCarl Dependahl
NEIL ###-#### WALL INSP
FIRE-Final Inspection10/27/199910/28/199910/28/1999AFAIL
DetailsJoe Tawney
Scheduled by a contractor via Hello! on 10/27/1999 at 14:27:12. Contact: ###-####. Final fail install ceiling tile at sprklr. Heads
FIRE-Final Inspection10/21/199910/22/199910/22/1999APART
DetailsJoe Tawney
###-#### Ok on sprkl. R/I, ok to cover
BLD-Framing/Rough-in10/20/199910/20/199910/20/1999PPART
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 10/20/1999 at 08:45:45. Contact: ###-####. Met w/ proj. mgr; ok to cover walls; need sprinkler R/I
Issue PAID IN FULL permit  8/9/1999
Telephone call  8/4/1999
LEFT MSG FOR NEIL THAT PERMIT IS READY FOR PICK UP
Inspection Record Card- Bld  7/30/1999
Print Occupancy Form  7/30/1999
Plan assigned to (DRS)7/28/1999 7/29/1999 PASS
DetailsDan Stuart
Routing - PLAN CHECK7/29/1999 7/29/1999 PASS
Approved as noted & attached.
PLANS/APPL TAKEN TO FRONT DESK  7/29/1999 PASS
Routing to permit desk for issuance of permit.
Print Pending Permit.LaserJet4  7/29/1999 PASS
Meeting  7/28/1999
Met with Neil Boel, Facilities Manager, Central District Health Bldg @ 707 Armstrong Pl.
Plan Reviewer's activity  7/28/1999
Researched files & Micro fiche to determine the actual construction type of the builidng and if there are any rated corridors required. File indicates V-1hour construction but fiche indicate construction type was changed to VN by provideing 5 separate tenant zones, each area having it's own exits & 20 min. door assemblies called for at doors between tenant areas. The builidng is fully sprinkled, the corridors are protected by smoke detection; areas are 10,000 sq. ft. or less and occupanct load under 100 per section 3305(g)5, 1991 UBC.
Application received  7/28/1999