Final | 3/6/2003 | 3/6/2003 | 3/6/2003 | P | PASS |
Jack Frank
|
|
|
###-#### correction made ok 3/6/2003 4:24:13 PM
|
DOC - Permit Finaled | 3/6/2003 | 3/6/2003 | 3/6/2003 | P | PASS |
Jack Frank
|
|
|
Finaled by inspector at 3/6/2003 4:24:18 PM
|
Final | 1/31/2003 | 1/31/2003 | 1/31/2003 | P | FAIL |
Jack Frank
|
|
|
###-#### cor. posted met owner shall provide gfci or non grd recept grd recept not allowed on non grd circuit 1/31/2003 1:59:22 PM
|
Final | 1/21/2003 | 1/21/2003 | 1/21/2003 | P | FAIL |
Jack Frank
|
|
|
jose- ###-#### cor. posted 210.52(A&B) needs outlet for wall space in din. rm ,410.8 shall provide proper clearence fixture in closet talked with guy at job site 1/21/2003 1:35:44 PM
|
Electrical Rough-In | 8/22/2002 | 8/23/2002 | 8/23/2002 | A | PASS |
Jack Frank
|
|
|
###-#### MIKE ok 8/23/2002 12:11:07 PM
|
Electrical Rough-In | 8/19/2002 | 8/20/2002 | 8/20/2002 | A | FAIL |
Jack Frank
|
|
|
###-#### 210.52(A) needs recept 2ft wall in new family rm, 250.148 grd outside light boxes, needs to check with structral on smoke detector locations? 8/20/2002 5:26:41 PM
|
Rough-In Permanent Service | 8/2/2002 | 8/5/2002 | 8/5/2002 | P | FAIL |
Jack Frank
|
|
|
###-#### mike or selena cor. posted met with owner 110.26 needs required clearence for service, 250 shall provide all required grounding and bonding for service, 230.24 clearence above roof with less than 4in12 pitch 230.72 all service disconnects shall be grouped inside or outside no violations to be retained a/c wiring, dryer, washer, subpanel, and owner to do work,not friend or general ? 8/5/2002 5:47:46 PM
|
Application received | | | 8/2/2002 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/2/2002 | | DONE |
|
|
|
|