Final | 12/13/2002 | 12/13/2002 | 12/13/2002 | P | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 12/13/2002 at 10:31:31. Contact: .
|
DOC - Permit Finaled | 12/13/2002 | 12/13/2002 | 12/13/2002 | P | PASS |
Pat Lass
|
|
|
Finaled by inspector at 12/13/2002 2:36:47 PM
|
Final | 12/11/2002 | 12/12/2002 | 12/12/2002 | A | FAIL |
Pat Lass
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
FPN:See 215.9 for ground-fault circuit-interrupter protection for personnel on feeders.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
210.70 Lighting Outlets Required.
(A) Dwelling Units. In dwelling units, lighting outlets shall be installed in accordance with 210.70(A)(1), (2), and (3).
(2) Additional Locations. Additional lighting outlets shall be installed in accordance with (a), (b), and (c).
(c) Where one or more lighting outlet(s) are installed for interior stairways, there shall be a wall switch at each floor level, and landing level that includes an entry way, to control the lighting outlet(s) where the stairway between floor levels has six risers or more.
Every thing must work for final inspection. (Whole house fan and outside fan-light)
12/12/2002 10:09:47 AM
|
Electrical Rough-In | 9/30/2002 | 9/30/2002 | 9/30/2002 | P | PASS |
Tim McCullough
|
|
|
rhonda-re-insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ok/ri 9/30/2002 2:24:41 PM
|
Electrical Rough-In | 9/26/2002 | 9/27/2002 | 9/27/2002 | A | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 09/26/2002 at 13:33:03. Contact: ###-####.
box fill and location of receps 9/27/2002 10:50:26 AM
|
Permanent Service | 9/27/2002 | 9/27/2002 | 9/27/2002 | A | PASS |
Pat Lass
|
|
|
P/S U/G N Ok
|
Application received | | | 9/19/2002 | | |
|
|
|
|
Issue & PRINT permit | | | 9/19/2002 | | |
|
|
|
|