Final | 5/30/2003 | 6/2/2003 | 6/2/2003 | A | PASS |
Pat Lass
|
|
|
###-####
|
DOC - Permit Finaled | 6/2/2003 | 6/2/2003 | 6/2/2003 | A | PASS |
Pat Lass
|
|
|
Finaled by inspector at 6/2/2003 10:29:55 AM
|
Final | 5/29/2003 | 5/29/2003 | 5/29/2003 | P | NR |
Pat Lass
|
|
|
bill ; Phone #: ###-#### Internet Inspection Request from: Annette Moore
not ready open boxes and wireing not complete 5/29/2003 3:14:16 PM
|
Electrical Rough-In | 11/25/2002 | 11/25/2002 | 11/25/2002 | P | PASS |
Jim Schmer
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Darla Downs 11/25/2002 4:23:59 PM p/s u/g new - ok 2-gng bxs, grd wires not made up together, check at time of finel. 11/25/2002 4:24:49 PM
|
Rough-In Permanent Service | 11/22/2002 | 11/22/2002 | 11/22/2002 | P | CANC |
Pat Lass
|
|
|
###-#### bill
$42 fee due corrections not made 11/22/2002 3:04:47 PM
|
Electrical Rough-In | 11/22/2002 | 11/22/2002 | 11/22/2002 | P | FAIL |
Pat Lass
|
|
|
correction not made $42 fee
|
Rough-In Permanent Service | 11/20/2002 | 11/20/2002 | 11/20/2002 | P | FAIL |
Pat Lass
|
|
|
###-#### -bill
314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
Boxes and conduit bodies shall be of sufficient size to provide free space for all enclosed conductors
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
(D) Cables and Raceways Parallel to Framing Members.
Upstairs
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
(B) Nonmetallic Boxes. One or more equipment grounding conductors brought into a nonmetallic outlet box shall be arranged so that a connection can be made to any fitting or device in that box requiring grounding.
210.52 Dwelling Unit Receptacle Outlets.
This section provides requirements for 125-volt, 15- and 20-ampere receptacle outlets.
2 Upstairs and change location of broken box by large slider.
11/20/2002 2:31:06 PM
|
Issue & PRINT permit | | | 11/20/2002 | | |
|
|
|
|
Application received | | | 11/20/2002 | | |
|
|
|
|