Permanent Service | 7/17/2003 | 7/18/2003 | 7/18/2003 | A | PASS |
Jack Frank
|
|
|
DAN; Phone #: ###-#### Internet Inspection Request from: Dixie Fellows
p/s o/h rec. ok 7/18/2003 10:38:18 AM
|
DOC - Permit Finaled | 7/18/2003 | 7/18/2003 | 7/18/2003 | A | PASS |
Jack Frank
|
|
|
Finaled by inspector at 7/18/2003 10:38:24 AM
|
Rough-In Permanent Service | 7/15/2003 | 7/16/2003 | 7/16/2003 | P | FAIL |
Jack Frank
|
|
|
DAN; Phone #: ###-#### Internet Inspection Request from: Darla Downs cor. posted called bond water system, needs 2 grd rods, seal 1/2 ko sub panel, no SMS equip grd bus sub panel, needs 10/3 romex dryer circuit from sub panel, use romex and box for door bell xformer circuit at sub panel , note make sure neutral is isolated at sub panel 7/16/2003 3:09:06 PM
|
Application received | | | 7/15/2003 | | |
|
|
|
|
Issue & PRINT permit | | | 7/15/2003 | | DONE |
|
|
|
|