Final | 1/7/2004 | 1/7/2004 | 1/7/2004 | P | PASS |
Jack Frank
|
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok 1/7/2004 1:29:24 PM
|
DOC - Permit Finaled | 1/7/2004 | 1/7/2004 | 1/7/2004 | P | PASS |
Jack Frank
|
|
|
Finaled by inspector at 1/7/2004 1:29:32 PM
|
Permanent Service | 1/6/2004 | 1/6/2004 | 1/6/2004 | P | NH |
Jack Frank
|
|
|
###-#### dan notice posted called 1/6/2004 2:16:48 PM
|
Final | 12/31/2003 | 12/31/2003 | 12/31/2003 | P | FAIL |
Jack Frank
|
|
|
Dan; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes cor. not made no common neutrals allowed from sub panel to old panel (jbox) in basement reinspection fee due called 12/31/2003 3:07:23 PM
|
Final | 12/14/2003 | 12/15/2003 | 12/15/2003 | A | FAIL |
Jack Frank
|
|
|
Please call homeowner 1st John, ###-####; Phone #: ###-#### Internet Inspection Request from: Dan Hobdey cor. and fee due posted, more violations created 250.8 no SMS equip bus , 300.2 no common neutral allowed, from sub panel to jbox in basement, shall grd sevice too electrode only not to sub panel 12/15/2003 10:02:19 AM
|
Rough-In Permanent Service | 12/10/2003 | 12/10/2003 | 12/10/2003 | P | NH |
Jack Frank
|
|
|
Dan --- please call homeowner for access. ###-####, John.; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes called left message 12/10/2003 2:38:23 PMcalled left message 12/10/2003 3:40:46 PM called for access no response 12/10/2003 3:52:25 PM
|
Electrical Rough-In | 11/12/2003 | 11/12/2003 | 11/12/2003 | P | FAIL |
Jack Frank
|
|
|
###-#### Dan --- please call first ###-#### homeowner for access John. r/i p/s failed cor posted called manufactures breakers only sub panel, 2 grd rods, 4 wire feed to range, range and dryer need 4 wire plug and pigtail, isolate grds and neuts at jbox basement, seal all unused openings 11/12/2003 4:47:14 PM
|
Issue permit | | | 11/12/2003 | | DONE |
|
|
|
|
Application received | | | 11/12/2003 | | |
|
|
|
|