Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberELE04-00305
StatusFinaled
Name SWANSON CHARLES &
Site Address 3212 W CAMROSE LN
Project Name 
Customer Number 
ePlanReview 
Description
per jack frank add "2" rooms one for the existing garage & added on other room.any questions call jack or ask marsha./3/6/06/mls
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/16/200610/18/200610/18/2006PPASS
DetailsBob Reichert
chuck ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, ok to final
Electrical Rough-In10/3/200610/4/200610/4/2006APASS
DetailsJim Schmer
Jim charles cell # is ###-#### see my notes to inspection request 10-03-06 ? call me remove outlet in 2 wire circuit, 2 gang bx next to door wires to short, remove baffles in wireway-chng to soffett with openings for lb and jbox, put grd wire in conduit jms
(F) Reprint permit  10/4/2006 DONE
Electrical Rough-In10/2/200610/3/200610/3/2006PFAIL
DetailsJack Frank
Charles no #, will call you to arrange time
corr. posted 03-06-06, 314.16 box fill, remove all devices installed so I can inspect makeup room back of garage not done, 10-03-06, built his own jbox, wireway ? dose not meet NEC 314.40,41 has high and low voltage mixed in it, 300.14 needs 6" free length conductor all locations,250.130 (C) 1,2,3,4,5 nongrounding recept replacement or branch circuit extensions shall meet rquirements as code noted states, or see 406.3 (D) for gfci protection for ungrounded systems, 300.3(B) shall install equip grd wire in raceway not on the outside of it 1/2 EMT in homemade jbox
Electrical Rough-In3/6/20063/6/20063/6/2006PFAIL
DetailsJack Frank
charles-- ###-####-- call 1st before insp
cor. posted met owner210.70 needs fixture for outside exit entry 314,29 LB shall not be cover, 406.8(B) needs inuse cover, BCC no violation retained remove all cord used as fixed wiring,, remove all devices from boxes so I can inspect, update permit for 2 rooms COW
(F) Reprint permit  3/6/2006  
Conference2/5/20042/5/20042/5/2004PPART
DetailsJack Frank
chuck please call for access; Phone #: ###-#### Internet Inspection Request from: Annette Moore 01 ok 2/5/2004 1:46:47 PM
Application received  2/3/2004  
Issue PAID IN FULL permit  2/3/2004 DONE