Final | 12/24/2013 | 12/24/2013 | 12/24/2013 | P | PASS |
Rock A. Hudson
|
|
|
Corrections completed on permit ele13-03542. Final ok
|
Final | 12/18/2013 | 12/19/2013 | 12/19/2013 | A | FAIL |
Rock A. Hudson
|
|
|
Before 11, call for access - April Phone #: ###-#### BCC-4-05-23 Unlawful to conceal. Basement wiring covered with out first being inspected. 210.52- Basement dows not have minimum reqired receptical outlet installed measured along floor line. 314.25- All boxes shall be complete with covers. Furnace disconnect. 422.30- A disconnecting means shall be provided for water heater. 110.3- Family room receptical outlet not working. 210.8- Back outdoor receptical shall have GFCI protection. 406.3(D)- Grounding type recepticals installed on non-grounded circuits shall have GFCI protection.
|
Change Status to I | | | 12/18/2013 | | DONE |
Christina Prado
|
|
|
Per Bob Archibald 12-13-13 - ok to reopen permits with 1/2 orig fee to get final inspections
|
(F) Reprint permit | | | 12/18/2013 | | DONE |
|
|
|
|
Electrical Rough-In | 8/19/2004 | 8/20/2004 | 8/20/2004 | A | PART |
William E Thomas
|
|
|
clyde; Phone #: ###-#### Internet Inspection Request from: Annette Moore
ri ok mainfloor and upstairs.
no cover allowes on basement 8/20/2004 9:04:47 AM
|
Rough-In Permanent Service | 8/5/2004 | 8/6/2004 | 8/6/2004 | P | FAIL |
Pat Lass
|
|
|
###-#### clyde
ground service to metal water pipe.
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
A connection shall be made between the one or more equipment grounding conductors and a box
Upstairs and main floor.
314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).
At panel
8/6/2004 2:12:31 PM 8/6/2004 2:21:11 PM
|
Permanent Service | 8/6/2004 | 8/6/2004 | 8/6/2004 | P | PART |
Pat Lass
|
|
|
P/S O/H R Ok
to transfer power to new location
|
Application received | | | 8/5/2004 | | |
|
|
|
|
Issue permit | | | 8/5/2004 | | DONE |
|
|
|
|