Permit Information
Permit NumberELE04-03683
StatusFinaled
Name LACY CONSTRUCTION
Site Address 9974 W FAIRVIEW AVE
Project Name 
Customer Number15-5
ePlanReview 
Description
400 AMP panel wiring for 2 story office $26,359 JRR 11-22-04///Final cert of value $26,359///8/18/05 BAS///
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice ELE7/25/20057/25/20058/18/2005 DONE
Second Notice has not been responded to.
Second Notice ELE7/13/20057/13/20057/25/2005 DONE
First Notice has not been responded to.
First Notice7/1/20057/1/20057/13/2005 DONE
DetailsBob Reichert
Final6/30/20057/1/20057/1/2005APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/30/2005 at 4:35:57 PM. Contact: ###-####. signed occ card, told owner to change 1 bkr to gfci for people, not equip. ok to final
Electrical Rough-In6/28/20056/28/20056/28/2005APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/28/2005 at 7:17:32 AM. Contact: ###-####. corrections made, ceiling cover ok both floors
Electrical Rough-In6/27/20056/27/20056/27/2005PFAIL
DetailsWilliam E Thomas
###-#### - craig Note: above grid ceiling
ballast wiring not protected in accordance with article 300 of the nec
Change Status to I  6/27/2005  
Temporary Service4/28/20054/29/20054/29/2005ACANC
DetailsBob Reichert
Scheduled by a contractor via Hello! on 4/28/2005 at 2:54:31 PM. Contact: ###-####. see added inspection 4/29/2005 9:01:56 AM
Permanent Service4/29/20054/29/20054/29/2005APASS
DetailsBob Reichert
p/s u/g n ok
Electrical Rough-In4/14/20054/15/20054/15/2005APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 4/14/2005 at 5:10:15 PM. Contact: ###-####. corrections made, ric walls for all and big room clg. 4/15/2005 9:31:31 AM
Electrical Rough-In4/13/20054/14/20054/14/2005AFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 4/13/2005 at 5:15:45 PM. Contact: ###-####. told contr, left corr notice, 300.4(A)(1) & (D) shall provide nail plates and 1 1/4" as code noted states, 250.126 shall use green ground screws 4/14/2005 10:11:58 AM
Electrical Rough-In3/30/20053/30/20053/30/2005PNR
DetailsBob Reichert
craig - ###-#### called contr and said all make-up to be done and mud rings before inspection 3/30/2005 1:40:07 PM
Change Status to I  3/30/2005 DONE
Was doc finaled due to having temp service included but I seperated that out per Jim Schmer and re-opened this permit for the building///3/30/05 BAS
Third Notice ELE1/28/20051/28/20053/18/2005 DONE
Second Notice has not been responded to.
Second Notice ELE1/14/20051/14/20051/28/2005 DONE
First Notice has not been responded to.
First Notice Sent 12/22/20041/14/2005 DONE
DOC - Permit Finaled12/22/200412/22/200412/22/2004PPASS
DetailsBob Reichert
Finaled by inspector at 12/22/2004 3:12:49 PM
Electrical Rough-In12/6/200412/6/200412/6/2004PPART
DetailsBob Reichert
underground conduit inspection please///craig; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cnd u/g for phone only. ok to cover 12/6/2004 12:50:43 PM
Issue permit  12/6/2004 DONE
Application received  11/22/2004